The DOI matches its Crossref record.
Level Set Analysis for Leukocyte Detection and Tracking
Abstract
We propose a cell detection and tracking solution using image-level sets computed via threshold decomposition. In contrast to existing methods where manual initialization is required to track individual cells, the proposed approach can automatically identify and track multiple cells by exploiting the shape and intensity characteristics of the cells. The capture of the cell boundary is considered as an evolution of a closed curve that maximizes image gradient along the curve enclosing a homogeneous region. An energy functional dependent upon the gradient magnitude along the cell boundary, the region homogeneity within the cell boundary and the spatial overlap of the detected cells is minimized using a variational approach. For tracking between frames, this energy functional is modified considering the spatial and shape consistency of a cell as it moves in the video sequence. The integrated energy functional complements shape-based segmentation with a spatial consistency based tracking technique. We demonstrate that an acceptable, expedient solution of the energy functional is possible through a search of the image-level lines: boundaries of connected components within the level sets obtained by threshold decomposition. The level set analysis can also capture multiple cells in a single frame rather than iteratively computing a single active contour for each individual cell. Results of cell detection using the energy functional approach and the level set approach are presented along with the associated processing time. Results of successful tracking of rolling leukocytes from a number of digital video sequences are reported and compared with the results from a correlation tracking scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An Automatic Learning-Based Framework for Robust Nucleus Segmentation
Xing, F., Xie, Y., & Yang, L. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2481436 · Cited by 351
Image processing and classification algorithm for yeast cell morphology in a microfluidic chip
Yang Yu, B., Elbuken, C., Ren, C. L., & Huissoon, J. P. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3589100 · Cited by 349
Segmenting and tracking fluorescent cells in dynamic 3-D microscopy with coupled active surfaces
Dufour, A., Shinin, V., Tajbakhsh, S., Guillen-Aghion, N., Olivo-Marin, J.-C., & Zimmer, C. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.852790 · Cited by 309
Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy
Dzyubachyk, O., van Cappellen, W. A., Essers, J., Niessen, W. J., & Meijering, E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2038693 · Cited by 255
SITUP: Scale Invariant Tracking Using Average Peak-to-Correlation Energy
Ma, H., Acton, S. T., & Lin, Z. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2962694 · Cited by 39
Self-citation
Metadata
- Authors
- Mukherjee, D. P., Ray, N., & Acton, S. T.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2004-04
- Volume
- 13
- Issue
- 4
- Pages
- 562-572
- ISSN
- 1057-7149 (ISSN-L)
- OpenAlex
- W2155296963
- Cited by
- 209
- References
- 0
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Level Set Analysis for Leukocyte Detection and Tracking. https://app.cochat.ai/papers/10.1109/tip.2003.819858
- The paper
- Mukherjee, D. P., Ray, N., & Acton, S. T. (2004). Level Set Analysis for Leukocyte Detection and Tracking. IEEE Transactions on Image Processing. https://doi.org/10.1109/tip.2003.819858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.