Statistical Reconstruction for Cosmic Ray Muon Tomography
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Highly penetrating cosmic ray muons constantly shower the earth at a rate of about 1 muon per cm2 per minute. We have developed a technique which exploits the multiple Coulomb scattering of these particles to perform nondestructive inspection without the use of artificial radiation. In prior work [1]-[3], we have described heuristic methods for processing muon data to create reconstructed images. In this paper, we present a maximum likelihood/expectation maximization tomographic reconstruction algorithm designed for the technique. This algorithm borrows much from techniques used in medical imaging, particularly emission tomography, but the statistics of muon scattering dictates differences. We describe the statistical model for multiple scattering, derive the reconstruction algorithm, and present simulated examples. We also propose methods to improve the robustness of the algorithm to experimental errors and events departing from the statistical model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444 · cited 4×
“…of scattering in each voxel is independent of the scattering in other voxels, the probability of the aggregate set of hidden 1 Although earlier papers by others described the algorithm, Dempster, Laird, and Rubin [9] coined the name EM algorithm and the standard terminology to define it.”
BackgroundInfluentialGeant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946 · cited 3×
“GEANT4 implements a more complete , accurate, and validated model for multiple scattering.”
MethodInfluentialEidelman, S., Hayes, K. G., Olive, K. A., Aguilar-Benitez, M., Amsler, C., Asner, D., Babu, K. S., Barnett, R. M., Beringer, J., Burchat, P. R., et al. (2004) · Physics Letters B · doi:10.1016/j.physletb.2004.06.001 · Cited by 6,673
Review of particle physics. Particle Data GroupPreprint
Eidelman, S., Höhler, G., Chivukula, R. S., Ткаченко, Н. П., Kayser, B. J., van Bibber, K., Harper, G., Webber, B. R., Rosenberg, L. J., Dahl, O. I., et al. (2004) · arXiv (Cornell University) · Cited by 2,394
Big Bang Nucleosynthesis (in "The Review of Particle Properties" 2004)
Fields, B. D., & Sarkar, S. (2004) · arXiv (Cornell University) · doi:10.48550/arxiv.astro-ph/0406663 · Cited by 2,300
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863 · cited 1×
“2 We develop our EM algorithm from a statistical perspective, but EM can be shown to be equivalent to scaled gradient descent [10], as well as a special case of incremental optimization transfer [11]. data is the product of the probability of each element.”
Method10.2 Maximum Likelihood from Incomplete Data
(2024) · Hierarchical Quantile Modeling · doi:10.1051/978-2-7598-3719-9.c026 · Cited by 780
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691 · cited 1×
“We are currently modifying it to evaluate the effect of quadratic and edge preserving penalty terms as in [13].”
MethodConvergent incremental optimization transfer algorithms: application to tomography
Ahn, S., Fessler, J. A., Blatt, D., & Hero, A. O. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862740 · Cited by 71 · cited 1×
“2 We develop our EM algorithm from a statistical perspective, but EM can be shown to be equivalent to scaled gradient descent [10], as well as a special case of incremental optimization transfer [11]. data is the product of the probability of each element.”
Method
Metadata
- Authors
- Schultz, L. J., Blanpied, G. S., Borozdin, K. N., Fraser, A. M., Hengartner, N. W., Klimenko, A. V., Morris, C. L., Orum, C., & Sossong, M. J.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2007-08
- Volume
- 16
- Issue
- 8
- Pages
- 1985-1993
- ISSN
- 1057-7149 (ISSN-L)
- 1941-0042
- OpenAlex
- W1966248051
- Cited by
- 178
- References
- 9
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.