Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

Expert PID control system for blood glucose control in critically Ill patients

Chee, F., Fernando, T.L., Savkin, A.V., van Heeden, V. · 2003 · IEEE Transactions on Information Technology in Biomedicine

Abstract

In this paper, the design of an expert proportional-integral-derivative (PID) control system for blood glucose regulation in patients, such as the intensive care population, is described. The control system applied the concept of expert system, and proportional, integral and derivative control in clinical sliding table technique, to effect a control algorithm in the form of an "active" sliding table that is used to prescribe insulin infusion rates. This combination provided dynamic properties to the sliding table control. Clinical results have shown a comparable performance between the control system and routine clinical treatment, in terms of blood glucose level maintained. Nevertheless, the control system is sensitive to sensor reading artefact, particularly in the lower ranges of blood glucose level, mandating manual intervention.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/titb.2003.821326

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Chee, F., Fernando, T. L., Savkin, A. V., & van Heeden, V.
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2003-12
Volume
7
Issue
4
Pages
419-425
ISSN
1089-7771 (ISSN-L)
OpenAlex
W2100097728
Cited by
176
References
0
FWCI
1.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Expert PID control system for blood glucose control in critically Ill patients. https://app.cochat.ai/papers/10.1109/titb.2003.821326
The paper
Chee, F., Fernando, T. L., Savkin, A. V., & van Heeden, V. (2003). Expert PID control system for blood glucose control in critically Ill patients. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2003.821326

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.