Cited by 9Medical Image Segmentation TechniquesMedical Imaging and AnalysisPreterm Birth and Chorioamnionitis

A Novel Algorithm for Computer-Assisted Measurement of Cervical Length from Transvaginal Ultrasound Images

Wu, M., Fraser, R.F., Chen, C.W.·2004·IEEE Transactions on Information Technology in Biomedicine

Abstract

The cervical length measured by transvaginal ultrasound is a proven clinical tool for predicting premature birth. The standard manual measurement of the cervix is limited by variability in the technique. In this research, we develop the first computer algorithm that is able to identify the anatomic landmarks of the cervix on a transvaginal ultrasound image and determine the standard cervical length. The system is composed of four stages: The first stage is adaptive speckle suppression using variable length sticks algorithm. The second stage is the location of the internal cervical opening or "os" using a region-based segmentation. The third stage is delineation of the cervical canal. The fourth stage uses gray level summation patterns and prior knowledge to first localize the tissue boundary of the external cervix, and then use a template to determine the specific location of the external os. The cervical length is determined and calculated to image scale. To validate the proposed algorithm, 101 cervical ultrasound images were selected from a series of 37 examinations performed on 17 patients over an eight-month period. Repeated measurements of cervical length using the computer-assisted method were compared with those carried out by two experienced sonographers. The median intraobserver variability for the 101 images using the computer-assisted method was significantly smaller than that of the manual method by either sonographer. In a pairwise comparison, the mean cervical length for the computer method matches with the mean manual cervical length.

Integrity signals

Registry

Crossref · 10.1109/titb.2004.832548

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wu, M., Fraser, R. F., & Chen, C. W.
Affiliations
  • University of Missouri (US)
  • St. John's Hospital (US)
  • Florida Institute of Technology (US)
ORCID
Wu, M.
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2004-09
Volume
8
Issue
3
Pages
333-342
ISSN
1089-7771 (ISSN-L)
OpenAlex
W2152142944
Cited by
9
References
17
Citations by year
2026: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2020: 1
FWCI
0.69
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
U.S. National Library of Medicine
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
  • Health Sciences › Medicine › Epidemiology › Preterm Birth and Chorioamnionitis
Keywords
cervical length measurement, transvaginal ultrasound, computer-aided image analysis, speckle reduction, region-based segmentation, template matching, preterm birth prediction, intraobserver variability
MeSH terms
Algorithms, Artificial Intelligence, Cervix Uteri, Female, Humans, Image Interpretation, Computer-Assisted, Pattern Recognition, Automated, Pregnancy, Vagina, Ultrasonography, Prenatal, Risk Assessment, Premature Birth

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review