The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hybrid Retinal Image Registration
Abstract
This work studies retinal image registration in the context of the National Institutes of Health (NIH) Early Treatment Diabetic Retinopathy Study (ETDRS) standard. The ETDRS imaging protocol specifies seven fields of each retina and presents three major challenges for the image registration task. First, small overlaps between adjacent fields lead to inadequate landmark points for feature-based methods. Second, the non-uniform contrast/intensity distributions due to imperfect data acquisition will deteriorate the performance of area-based techniques. Third, high-resolution images contain large homogeneous nonvascular/texureless regions that weaken the capabilities of both feature-based and area-based techniques. In this work, we propose a hybrid retinal image registration approach for ETDRS images that effectively combines both area-based and feature-based methods. Four major steps are involved. First, the vascular tree is extracted by using an efficient local entropy-based thresholding technique. Next, zeroth-order translation is estimated by maximizing mutual information based on the binary image pair (area-based). Then image quality assessment regarding the ETDRS field definition is performed based on the translation model. If the image pair is accepted, higher-order transformations will be involved. Specifically, we use two types of features, landmark points and sampling points, for affine/quadratic model estimation. Three empirical conditions are derived experimentally to control the algorithm progress, so that we can achieve the lowest registration error and the highest success rate. Simulation results on 504 pairs of ETDRS images show the effectiveness and robustness of the proposed algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Similar methods were also proposed in the case of abdominal CT [354] and retinal [355] images.”
MethodA Partial Intensity Invariant Feature Descriptor for Multimodal Retinal Image Registration
Chen, J., Tian, J., Lee, N., Zheng, J., Smith, R. T., & Laine, A. F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2042169 · Cited by 311
Metadata
- Authors
- Chanwimaluang, T., Fan, G., & Fransen, S. R.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2006-01
- Volume
- 10
- Issue
- 1
- Pages
- 129-142
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2125956239
- Cited by
- 161
- References
- 3
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid Retinal Image Registration. https://app.cochat.ai/papers/10.1109/titb.2005.856859
- The paper
- Chanwimaluang, T., Fan, G., & Fransen, S. R. (2006). Hybrid Retinal Image Registration. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2005.856859
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.