Approximate Entropy-Based Epileptic EEG Detection Using Artificial Neural Networks
Abstract
The electroencephalogram (EEG) signal plays an important role in the diagnosis of epilepsy. The EEG recordings of the ambulatory recording systems generate very lengthy data and the detection of the epileptic activity requires a time-consuming analysis of the entire length of the EEG data by an expert. The traditional methods of analysis being tedious, many automated diagnostic systems for epilepsy have emerged in recent years. This paper proposes a neural-network-based automated epileptic EEG detection system that uses approximate entropy (ApEn) as the input feature. ApEn is a statistical parameter that measures the predictability of the current amplitude values of a physiological signal based on its previous amplitude values. It is known that the value of the ApEn drops sharply during an epileptic seizure and this fact is used in the proposed system. Two different types of neural networks, namely, Elman and probabilistic neural networks, are considered in this paper. ApEn is used for the first time in the proposed system for the detection of epilepsy using neural networks. It is shown that the overall accuracy values as high as 100% can be achieved by using the proposed system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Physiological time-series analysis: what does regularity quantify?
Pincus, S. M., & Goldberger, A. L. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.266.4.h1643 · Cited by 1,315
A regularity statistic for medical data analysis
Pincus, S. M., Gladstone, I. M., & Ehrenkranz, R. A. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01619355 · Cited by 788
Automatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674
Artificial neural network based epileptic detection using time-domain and frequency-domain features
Srinivasan, V., Eswaran, C., & Sriraam, A. N. (2005) · Journal of Medical Systems · doi:10.1007/s10916-005-6133-1 · Cited by 417
Self-citationAnticipation of epileptic seizures from standard EEG recordings
Le Van Quyen, M., Martinerie, J., Navarro, V., Boon, P., D'Havé, M., Adam, C., Renault, B., Varela, F., & Baulac, M. (2001) · The Lancet · doi:10.1016/s0140-6736(00)03591-1 · Cited by 390
Bruhn, J., Röpcke, H., & Hoeft, A. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00016 · Cited by 368
A neural-network-based detection of epilepsy
Nigam, V. P., & Graupe, D. (2004) · Neurological Research · doi:10.1179/016164104773026534 · Cited by 350
Pincus, S. M., Mulligan, T., Iranmanesh, A., Gheorghiu, S., Godschalk, M., & Veldhuis, J. D. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.24.14100 · Cited by 337
Qu, H., & Gotman, J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.552241 · Cited by 248
Heart rate control in normal and aborted-SIDS infants
Pincus, S. M., Cummins, T. R., & Haddad, G. G. (1993) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1993.264.3.r638 · Cited by 208
Estimating regularity in epileptic seizure time-series data
Radhakrishnan, N., & Gangadhar, B. N. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677174 · Cited by 196
Detection of Seizure Activity in EEG by an Artificial Neural Network: A Preliminary Study
Pradhan, N., Puthusserypady, S. K., & Arunodaya, G. R. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0022 · Cited by 143
State-dependent spike detection: concepts and preliminary results
Gotman, J., & Wang, L. Y. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90151-s · Cited by 129
Derived fuzzy knowledge model for estimating the depth of anesthesia
Zhang, X.-S., & Roy, R. J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914794 · Cited by 112
An Adaptive Structure Neural Networks with Application to EEG Automatic Seizure Detection
Weng, W., & Khorasani, K. (1996) · Neural Networks · doi:10.1016/0893-6080(96)00032-9 · Cited by 107
Computerized seizure detection of complex partial seizures
Murro, A. M., King, D. W., Smith, J. R., Gallagher, B. B., Flanigin, H. F., & Meador, K. J. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90128-q · Cited by 92
Epileptic activity recognition in EEG recording
Diambra, L. A., de Figueiredo, J. C. B., & Malta, C. P. (1999) · Physica A Statistical Mechanics and its Applications · doi:10.1016/s0378-4371(99)00368-4 · Cited by 77
Kıymık, M. K., Subaşı, A., & Özçalık, H. R. (2004) · Journal of Medical Systems · doi:10.1023/b:joms.0000044954.85566.a9 · Cited by 64
Kim, W., Yoon, Y.-Z., Bae, J., et al. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/016 · Cited by 41
Cited by
Automated EEG analysis of epilepsy: A review
Acharya, U. R., Vinitha Sree, S., Swapna, G., Martis, R. J., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.014 · Cited by 837
Epileptic Seizure Detection in EEGs Using Time–Frequency Analysis
Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2017939 · Cited by 744
Automated diagnosis of epileptic EEG using entropies
Acharya, U. R., Molinari, F., Sree, S. V., Chattopadhyay, S., Ng, K.-H., & Suri, J. S. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.07.007 · Cited by 626
Detection of epileptic electroencephalogram based on Permutation Entropy and Support Vector Machines
Nicolaou, N., & Georgiou, J. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.07.008 · Cited by 518
Application of entropies for automated diagnosis of epilepsy using EEG signals: A review
Acharya, U. R., Fujita, H., Sudarshan, V. K., Bhat, S., & Koh, J. E. W. (2015) · Knowledge-Based Systems · doi:10.1016/j.knosys.2015.08.004 · Cited by 492
Metadata
- Authors
- Srinivasan, V., Eswaran, C., & Sriraam, N.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2007-05
- Volume
- 11
- Issue
- 3
- Pages
- 288-295
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2102244548
- Cited by
- 591
- References
- 22
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.