The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System
Abstract
Techniques such as ballistocardiography (BCG) that can provide noninvasive long-term physiological monitoring have gained interest due to a growing recognition of adverse effects from poor sleep and sleep disorders. The noninvasive analysis of physiological signals (NAPS) system is a BCG-based monitoring system developed to measure heart rate, breathing rate, and musculoskeletal movement that shows promise as a general sleep analysis tool. Overnight sleep studies were conducted on 40 healthy subjects during a clinical trial at the University of Virginia. The NAPS system's measures of heart rate and breathing rate were compared to ECG, pulse oximetry, and respiratory inductance plethysmography (RIP). The subjects were split into a training dataset and a validation dataset, maintaining similar demographics in each set. The NAPS system accurately detected heart rate, averaged over the prescribed 30-s epochs, to within less than 2.72 beats per minute of ECG, and accurately detected breathing rate, averaged over the same epochs, to within 2.10 breaths per minute of RIP bands used in polysomnography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Health monitoring in the home of the future
Korhonen, I., Parkka, J., & Van Gils, M. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213628 · Cited by 486
Chee, Y., Han, J., Youn, J., & Park, K. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/007 · Cited by 111
Respiratory monitoring using an air-mattress system
Chow, P., Nagendra, G., Abisheganaden, J., & Wang, Y. T. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/3/301 · Cited by 45
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 276
Metadata
- Authors
- Mack, D. C., Patrie, J. T., Suratt, P. M., Felder, R. A., & Alwan, M.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2009-01
- Volume
- 13
- Issue
- 1
- Pages
- 111-120
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2134563592
- Cited by
- 195
- References
- 3
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System. https://app.cochat.ai/papers/10.1109/titb.2008.2007194
- The paper
- Mack, D. C., Patrie, J. T., Suratt, P. M., Felder, R. A., & Alwan, M. (2009). Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2008.2007194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.