The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Classification of Electrocardiogram Signals With Support Vector Machines and Particle Swarm Optimization
Abstract
The aim of this paper is twofold. First, we present a thorough experimental study to show the superiority of the generalization capability of the support vector machine (SVM) approach in the automatic classification of electrocardiogram (ECG) beats. Second, we propose a novel classification system based on particle swarm optimization (PSO) to improve the generalization performance of the SVM classifier. For this purpose, we have optimized the SVM classifier design by searching for the best value of the parameters that tune its discriminant function, and upstream by looking for the best subset of features that feed the classifier. The experiments were conducted on the basis of ECG data from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database to classify five kinds of abnormal waveforms and normal beats. In particular, they were organized so as to test the sensitivity of the SVM classifier and that of two reference classifiers used for comparison, i.e., the k-nearest neighbor (kNN) classifier and the radial basis function (RBF) neural network classifier, with respect to the curse of dimensionality and the number of available training beats. The obtained results clearly confirm the superiority of the SVM approach as compared to traditional classifiers, and suggest that further substantial improvements in terms of classification accuracy can be achieved by the proposed PSO-SVM classification system. On an average, over three experiments making use of a different total number of training beats (250, 500, and 750, respectively), the PSO-SVM yielded an overall accuracy of 89.72% on 40438 test beats selected from 20 patient records against 85.98%, 83.70%, and 82.34% for the SVM, the kNN, and the RBF classifiers, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Cross validatory choice and assessment of statistical predictions
Stone, M. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00994.x · Cited by 10,881
A comparison of methods for multiclass support vector machines
Hsu, C.-W., & Lin, C.-J. (2002) · IEEE Transactions on Neural Networks · doi:10.1109/72.991427 · Cited by 6,838
Agresti, A. (2002) · Wiley Series in Probability and Statistics · doi:10.1002/0471249688 · Cited by 6,746
Classification of hyperspectral remote sensing images with support vector machines
Melgani, F., & Bruzzone, L. (2004) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2004.831865 · Cited by 4,411
Self-citationPattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Barker, L. (2002) · Technometrics · doi:10.1198/tech.2002.s659 · Cited by 2,477
A Particle Swarm Optimization Approach for Optimum Design of PID Controller in AVR System
Gaing, Z.-L. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.821821 · Cited by 1,774
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
Cited by
A comprehensive survey on support vector machine classification: Applications, challenges and trends
Cervantes, J., Garcia-Lamont, F., Rodríguez-Mazahua, L., & Lopez, A. (2020) · Neurocomputing · doi:10.1016/j.neucom.2019.10.118 · Cited by 2,381
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Deep learning approach for active classification of electrocardiogram signals
Rahhal, M. M. A., Bazi, Y., AlHichri, H., Alajlan, N., Melgani, F., & Yager, R. R. (2016) · Information Sciences · doi:10.1016/j.ins.2016.01.082 · Cited by 627
Self-citationECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network
Huang, J., Chen, B., Yao, B., & He, W. (2019) · IEEE Access · doi:10.1109/access.2019.2928017 · Cited by 591
LSTM-Based ECG Classification for Continuous Monitoring on Personal Wearable Devices
Saadatnejad, S., Oveisi, M., & Hashemi, M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2911367 · Cited by 406
Metadata
- Authors
- Melgani, F., & Bazi, Y.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2008-09
- Volume
- 12
- Issue
- 5
- Pages
- 667-677
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2125654608
- Cited by
- 525
- References
- 24
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Classification of Electrocardiogram Signals With Support Vector Machines and Particle Swarm Optimization. https://app.cochat.ai/papers/10.1109/titb.2008.923147
- The paper
- Melgani, F., & Bazi, Y. (2008). Classification of Electrocardiogram Signals With Support Vector Machines and Particle Swarm Optimization. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2008.923147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.