Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 591

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network

Open access
Huang, Jingshan, Chen, Binqiang, Yao, Bin, He, Wangpeng·2019·IEEE Access

Abstract

The classification of electrocardiogram (ECG) signals is very important for the automatic diagnosis of heart disease. Traditionally, it is divided into two steps, including the step of feature extraction and the step of pattern classification. Owing to recent advances in artificial intelligence, it has been demonstrated that deep neural network, which trained on a huge amount of data, can carry out the task of feature extraction directly from the data and recognize cardiac arrhythmias better than professional cardiologists. This paper proposes an ECG arrhythmia classification method using two-dimensional (2D) deep convolutional neural network (CNN). The time domain signals of ECG, belonging to five heart beat types including normal beat (NOR), left bundle branch block beat (LBB), right bundle branch block beat (RBB), premature ventricular contraction beat (PVC), and atrial premature contraction beat (APC), were first transformed into time-frequency spectrograms by short-time Fourier transform. Subsequently, the spectrograms of the five arrhythmia types were utilized as input to the 2D-CNN such that the ECG arrhythmia types were identified and classified finally. Using ECG recordings from the MIT-BIH arrhythmia database as the training and testing data, the classification results show that the proposed 2D-CNN model can reach an averaged accuracy of 99.00%. On the other hand, in order to achieve optimal classification performances, the model parameter optimization was investigated. It was found when the learning rate is 0.001 and the batch size parameter is 2500, the classifier achieved the highest accuracy and the lowest loss. We also compared the proposed 2D-CNN model with a conventional one-dimensional CNN model. Comparison results show that the 1D-CNN classifier can achieve an averaged accuracy of 90.93%. Therefore, it is validated that the proposed CNN classifier using ECG spectrograms as input can achieve improved classification accuracy without additional manual pre-processing of the ECG signals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2019.2928017

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 28 references

Cited by

See all 591

Metadata

Authors
Huang, J., Chen, B., Yao, B., & He, W.
Venue
IEEE Access
Published
2019
Volume
7
Pages
92871-92880
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2961638199
Cited by
591
References
28
FWCI
44.01
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network. https://app.cochat.ai/papers/10.1109/access.2019.2928017
The paper
Huang, J., Chen, B., Yao, B., & He, W. (2019). ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network. IEEE Access. https://doi.org/10.1109/access.2019.2928017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.