The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network
Open accessAbstract
The classification of electrocardiogram (ECG) signals is very important for the automatic diagnosis of heart disease. Traditionally, it is divided into two steps, including the step of feature extraction and the step of pattern classification. Owing to recent advances in artificial intelligence, it has been demonstrated that deep neural network, which trained on a huge amount of data, can carry out the task of feature extraction directly from the data and recognize cardiac arrhythmias better than professional cardiologists. This paper proposes an ECG arrhythmia classification method using two-dimensional (2D) deep convolutional neural network (CNN). The time domain signals of ECG, belonging to five heart beat types including normal beat (NOR), left bundle branch block beat (LBB), right bundle branch block beat (RBB), premature ventricular contraction beat (PVC), and atrial premature contraction beat (APC), were first transformed into time-frequency spectrograms by short-time Fourier transform. Subsequently, the spectrograms of the five arrhythmia types were utilized as input to the 2D-CNN such that the ECG arrhythmia types were identified and classified finally. Using ECG recordings from the MIT-BIH arrhythmia database as the training and testing data, the classification results show that the proposed 2D-CNN model can reach an averaged accuracy of 99.00%. On the other hand, in order to achieve optimal classification performances, the model parameter optimization was investigated. It was found when the learning rate is 0.001 and the batch size parameter is 2500, the classifier achieved the highest accuracy and the lowest loss. We also compared the proposed 2D-CNN model with a conventional one-dimensional CNN model. Comparison results show that the 1D-CNN classifier can achieve an averaged accuracy of 90.93%. Therefore, it is validated that the proposed CNN classifier using ECG spectrograms as input can achieve improved classification accuracy without additional manual pre-processing of the ECG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Varatharajan, R., Manogaran, G., & Priyan, M. K. (2018) · Multimedia Tools and Applications · doi:10.1007/s11042-017-5318-1 · Cited by 207
RetractedBackpropagation Applied to Handwritten Zip Code Recognition
LeCun, Y., Boser, B., Denker, J. S., Henderson, D., Howard, R. E., Hubbard, W., & Jackel, L. D. (1989) · Neural Computation · doi:10.1162/neco.1989.1.4.541 · Cited by 11,891
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
Kiranyaz, S., Ince, T., & Gabbouj, M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468589 · Cited by 1,912
Yildirim, Ö. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.03.016 · Cited by 833
Cardiologist-Level Arrhythmia Detection with Convolutional Neural Networks
Rajpurkar, P., Hannun, A., Haghpanahi, M., Bourn, C., & Ng, A. Y. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1707.01836 · Cited by 595
Melgani, F., & Bazi, Y. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.923147 · Cited by 525
ECG Classification Using Wavelet Packet Entropy and Random Forests
Li, T., & Zhou, M. (2016) · Entropy · doi:10.3390/e18080285 · Cited by 478
Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains
Kabir, M. A., & Shahnaz, C. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.11.003 · Cited by 444
Elhaj, F. A., Salim, N., Harris, A. R., Swee, T. T., & Ahmed, T. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.024 · Cited by 433
Cited by
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
Deep learning in ECG diagnosis: A review
Liu, X., Wang, H., Li, Z., & Qin, L. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107187 · Cited by 436
Clustering-Based Speech Emotion Recognition by Incorporating Learned Features and Deep BiLSTM
Mustaqeem, Sajjad, M., & Kwon, S. (2020) · IEEE Access · doi:10.1109/access.2020.2990405 · Cited by 402
2D Materials in Flexible Electronics: Recent Advances and Future Prospectives
Katiyar, A. K., Hoang, A. T., Xu, D., Hong, J., Kim, B. J., Ji, S., & Ahn, J.-H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00302 · Cited by 363
Murat, F., Yildirim, O., Talo, M., Baloglu, U. B., Demir, Y., & Acharya, U. R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103726 · Cited by 326
Metadata
- Authors
- Huang, J., Chen, B., Yao, B., & He, W.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 92871-92880
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2961638199
- Cited by
- 591
- References
- 28
- FWCI
- 44.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network. https://app.cochat.ai/papers/10.1109/access.2019.2928017
- The paper
- Huang, J., Chen, B., Yao, B., & He, W. (2019). ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network. IEEE Access. https://doi.org/10.1109/access.2019.2928017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.