The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Classification of Electrocardiogram Signals With Support Vector Machines and Particle Swarm Optimization
Abstract
The aim of this paper is twofold. First, we present a thorough experimental study to show the superiority of the generalization capability of the support vector machine (SVM) approach in the automatic classification of electrocardiogram (ECG) beats. Second, we propose a novel classification system based on particle swarm optimization (PSO) to improve the generalization performance of the SVM classifier. For this purpose, we have optimized the SVM classifier design by searching for the best value of the parameters that tune its discriminant function, and upstream by looking for the best subset of features that feed the classifier. The experiments were conducted on the basis of ECG data from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database to classify five kinds of abnormal waveforms and normal beats. In particular, they were organized so as to test the sensitivity of the SVM classifier and that of two reference classifiers used for comparison, i.e., the k-nearest neighbor (kNN) classifier and the radial basis function (RBF) neural network classifier, with respect to the curse of dimensionality and the number of available training beats. The obtained results clearly confirm the superiority of the SVM approach as compared to traditional classifiers, and suggest that further substantial improvements in terms of classification accuracy can be achieved by the proposed PSO-SVM classification system. On an average, over three experiments making use of a different total number of training beats (250, 500, and 750, respectively), the PSO-SVM yielded an overall accuracy of 89.72% on 40438 test beats selected from 20 patient records against 85.98%, 83.70%, and 82.34% for the SVM, the kNN, and the RBF classifiers, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Cross validatory choice and assessment of statistical predictions
Stone, M. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00994.x · Cited by 10,881
A comparison of methods for multiclass support vector machines
Hsu, C.-W., & Lin, C.-J. (2002) · IEEE Transactions on Neural Networks · doi:10.1109/72.991427 · Cited by 6,838
Agresti, A. (2002) · Wiley Series in Probability and Statistics · doi:10.1002/0471249688 · Cited by 6,746
Classification of hyperspectral remote sensing images with support vector machines
Melgani, F., & Bruzzone, L. (2004) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2004.831865 · Cited by 4,411
Self-citationPattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Barker, L. (2002) · Technometrics · doi:10.1198/tech.2002.s659 · Cited by 2,477
A Particle Swarm Optimization Approach for Optimum Design of PID Controller in AVR System
Gaing, Z.-L. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.821821 · Cited by 1,774
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
Support vector machines for 3D object recognition
Pontil, M., & Verri, A. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.683777 · Cited by 812
A support vector machine approach for detection of microcalcifications
El-Naqa, I., Yang, Y., Wernick, M. N., Galatsanos, N. P., & Nishikawa, R. M. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806569 · Cited by 571
Support Vector Machine-Based Expert System for Reliable Heartbeat Recognition
Osowski, S., Hoai, L. T., & Markiewicz, T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824138 · Cited by 536
ECG beat recognition using fuzzy hybrid neural network
Osowski, S., & Linh, T. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959322 · Cited by 518
A Patient-Adapting Heartbeat Classifier Using ECG Morphology and Heartbeat Interval Features
de Chazal, P., & Reilly, R. B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883802 · Cited by 497
Toward an Optimal SVM Classification System for Hyperspectral Remote Sensing Images
Bazi, Y., & Melgani, F. (2006) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2006.880628 · Cited by 430
Self-citationInan, O. T., Giovangrandi, L., & Kovacs, G. T. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880879 · Cited by 402
ECG signal analysis through hidden Markov models
Andreao, R. V., Dorizzi, B., & Boudy, J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877103 · Cited by 293
Using Wavelet Transform and Fuzzy Neural Network for VPC Detection From the Holter ECG
Shyu, L.-Y., Wu, Y.-H., & Hu, W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824131 · Cited by 236
MIT (2019) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.3477542 · Cited by 183
On-line heart beat recognition using hermite polynomials and neuro-fuzzy network
Linh, T. H., Osowski, S., & Stodolski, M. (2003) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2003.816841 · Cited by 178
Bruzzone, L., & Prieto, D. F. (1999) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.752239 · Cited by 162
A Rough-Set-Based Inference Engine for ECG Classification
Mitra, S., Mitra, M., & Chaudhuri, B. B. (2006) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2006.884279 · Cited by 159
Combining support vector machine learning with the discrete cosine transform in image compression
Robinson, J., & Kecman, V. (2003) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2003.813842 · Cited by 80
Cited by
A comprehensive survey on support vector machine classification: Applications, challenges and trends
Cervantes, J., Garcia-Lamont, F., Rodríguez-Mazahua, L., & Lopez, A. (2020) · Neurocomputing · doi:10.1016/j.neucom.2019.10.118 · Cited by 2,381
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Deep learning approach for active classification of electrocardiogram signals
Rahhal, M. M. A., Bazi, Y., AlHichri, H., Alajlan, N., Melgani, F., & Yager, R. R. (2016) · Information Sciences · doi:10.1016/j.ins.2016.01.082 · Cited by 627
Self-citationECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network
Huang, J., Chen, B., Yao, B., & He, W. (2019) · IEEE Access · doi:10.1109/access.2019.2928017 · Cited by 591
Classification of EMG signals using PSO optimized SVM for diagnosis of neuromuscular disorders
Subasi, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.01.020 · Cited by 478
Metadata
- Authors
- Melgani, F., & Bazi, Y.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2008-09
- Volume
- 12
- Issue
- 5
- Pages
- 667-677
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2125654608
- Cited by
- 525
- References
- 24
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.