Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record.

A Wearable ECG Acquisition System With Compact Planar-Fashionable Circuit Board-Based Shirt

Yoo, J., Long Yan, Seulki Lee, Hyejung Kim, Hoi-Jun Yoo·2009·IEEE Transactions on Information Technology in Biomedicine

Abstract

A wearable electrocardiogram (ECG) acquisition system implemented with planar-fashionable circuit board (P-FCB)-based shirt is presented. The proposed system removes cumbersome wires from conventional Holter monitor system for convenience. Dry electrodes screen-printed directly on fabric enables long-term monitoring without skin irritation. The ECG monitoring shirt exploits a monitoring chip with a group of electrodes around the body, and both the electrodes and the interconnection are implemented using P-FCB to enhance wearability and to lower production cost. The characteristics of P-FCB electrode are shown, and the prototype hardware is implemented to successfully verify the proposed concept.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/titb.2009.2033053

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Yoo, J., Yan, L., Lee, S., Kim, H., & Yoo, H.-J.
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2009-11
Volume
13
Issue
6
Pages
897-902
ISSN
1089-7771 (ISSN-L)
OpenAlex
W2159834109
Cited by
181
References
0
FWCI
6.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Wearable ECG Acquisition System With Compact Planar-Fashionable Circuit Board-Based Shirt. https://app.cochat.ai/papers/10.1109/titb.2009.2033053
The paper
Yoo, J., Yan, L., Lee, S., Kim, H., & Yoo, H.-J. (2009). A Wearable ECG Acquisition System With Compact Planar-Fashionable Circuit Board-Based Shirt. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2009.2033053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.