The DOI matches its Crossref record.
A Wearable ECG Acquisition System With Compact Planar-Fashionable Circuit Board-Based Shirt
Abstract
A wearable electrocardiogram (ECG) acquisition system implemented with planar-fashionable circuit board (P-FCB)-based shirt is presented. The proposed system removes cumbersome wires from conventional Holter monitor system for convenience. Dry electrodes screen-printed directly on fabric enables long-term monitoring without skin irritation. The ECG monitoring shirt exploits a monitoring chip with a group of electrodes around the body, and both the electrodes and the interconnection are implemented using P-FCB to enhance wearability and to lower production cost. The characteristics of P-FCB electrode are shown, and the prototype hardware is implemented to successfully verify the proposed concept.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Yang, G., Xie, L., Mäntysalo, M., Zhou, X., Pang, Z., Xu, L. D., Kao-Walter, S., Chen, Q., & Zheng, L.-R. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2307795 · Cited by 696
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
Self-Powered Wearable Electrocardiography Using a Wearable Thermoelectric Power Generator
Kim, C. S., Yang, H. M., Lee, J., Lee, G. S., Choi, H., Kim, Y. J., Lim, S. H., Cho, S. H., & Cho, B. J. (2018) · ACS Energy Letters · doi:10.1021/acsenergylett.7b01237 · Cited by 314
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 288
Alam, M. M., Malik, H., Khan, M. I., Pardy, T., Kuusik, A., & Le Moullec, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2853148 · Cited by 272
Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring
Hatamie, A., Angizi, S., Kumar, S., Pandey, C. M., Simchi, A., Willander, M., & Malhotra, B. D. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6827 · Cited by 184
Metadata
- Authors
- Yoo, J., Yan, L., Lee, S., Kim, H., & Yoo, H.-J.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2009-11
- Volume
- 13
- Issue
- 6
- Pages
- 897-902
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2159834109
- Cited by
- 181
- References
- 0
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.