The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Classification of Seizure and Nonseizure EEG Signals Using Empirical Mode Decomposition
Abstract
In this paper, we present a new method for classification of electroencephalogram (EEG) signals using empirical mode decomposition (EMD) method. The intrinsic mode functions (IMFs) generated by EMD method can be considered as a set of amplitude and frequency modulated (AM-FM) signals. The Hilbert transformation of IMFs provides an analytic signal representation of the IMFs. The two bandwidths, namely amplitude modulation bandwidth (B(AM)) and frequency modulation bandwidth (B(FM)), computed from the analytic IMFs, have been used as an input to least squares support vector machine (LS-SVM) for classifying seizure and non-seizure EEG signals. The proposed method for classification of EEG signals based on the bandwidth features (B(A M) and B (FM)) and the LS-SVM has provided better classification accuracy than the method of Liang et. al [20]. The experimental results with the recorded EEG signals from a published dataset are included to show the effectiveness of the proposed method for EEG signal classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Least Squares Support Vector Machine Classifiers
Suykens, J. A. K., & Vandewalle, J. (1999) · Neural Processing Letters · doi:10.1023/a:1018628609742 · Cited by 9,362
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Empirical Mode Decomposition as a Filter Bank
Flandrin, P., Rilling, G., & Goncalves, P. (2004) · IEEE Signal Processing Letters · doi:10.1109/lsp.2003.821662 · Cited by 2,583
Time-Frequency Signal Analysis and Processing
(2016) · doi:10.1016/c2012-0-00024-5 · Cited by 1,340
EEG signal classification using wavelet feature extraction and a mixture of expert model.
SUBASI, A. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2006.02.005 · Cited by 1,182
Analysis of EEG records in an epileptic patient using wavelet transform
Adeli, H., Zhou, Z., & Dadmehr, N. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00340-0 · Cited by 1,154
Multivariate empirical mode decomposition
Rehman, N., & Mandic, D. P. (2010) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2009.0502 · Cited by 885
Epileptic Seizure Detection in EEGs Using Time–Frequency Analysis
Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2017939 · Cited by 744
Cited by
Sharma, R., & Pachori, R. B. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2014.08.030 · Cited by 413
Self-citationA review of feature extraction and performance evaluation in epileptic seizure detection using EEG
Boonyakitanont, P., Lek-uthai, A., Chomtho, K., & Songsiri, J. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101702 · Cited by 390
Sharma, M., Pachori, R. B., & Rajendra Acharya, U. (2017) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.03.023 · Cited by 387
Self-citationRiaz, F., Hassan, A., Rehman, S., Niazi, I. K., & Dremstrup, K. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2441835 · Cited by 358
Sharma, R., Pachori, R., & Acharya, U. (2015) · Entropy · doi:10.3390/e17020669 · Cited by 305
Self-citationFeature extraction and recognition of ictal EEG using EMD and SVM
Li, S., Zhou, W., Yuan, Q., Geng, S., & Cai, D. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.04.002 · Cited by 300
Bhattacharyya, A., Pachori, R., Upadhyay, A., & Acharya, U. (2017) · Applied Sciences · doi:10.3390/app7040385 · Cited by 284
Self-citationMaheshwari, S., Pachori, R. B., & Acharya, U. R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2544961 · Cited by 283
Self-citationPachori, R. B., & Patidar, S. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.11.014 · Cited by 272
Self-citationEEG signal classification using universum support vector machine
Richhariya, B., & Tanveer, M. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.03.053 · Cited by 255
Classification of ictal and seizure-free EEG signals using fractional linear prediction
Joshi, V., Pachori, R. B., & Vijesh, A. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.08.006 · Cited by 254
Self-citationArtificial Intelligence Techniques for Automated Diagnosis of Neurological Disorders
Raghavendra, U., Acharya, U. R., & Adeli, H. (2019) · European Neurology · doi:10.1159/000504292 · Cited by 174
A robust methodology for classification of epileptic seizures in EEG signals
Tzimourta, K. D., Tzallas, A. T., Giannakeas, N., Astrakas, L. G., Tsalikakis, D. G., Angelidis, P., & Tsipouras, M. G. (2019) · Health and Technology · doi:10.1007/s12553-018-0265-z · Cited by 109
Metadata
- Authors
- Bajaj, V., & Pachori, R. B.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-11
- Volume
- 16
- Issue
- 6
- Pages
- 1135-1142
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W1990441178
- Cited by
- 472
- References
- 27
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.