The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Artifact Removal in Physiological Signals—Practices and Possibilities
Abstract
The combination of reducing birth rate and increasing life expectancy continues to drive the demographic shift toward an aging population. This, in turn, places an ever-increasing burden on healthcare due to the increasing prevalence of patients with chronic illnesses and the reducing income-generating population base needed to sustain them. The need to urgently address this healthcare "time bomb" has accelerated the growth in ubiquitous, pervasive, distributed healthcare technologies. The current move from hospital-centric healthcare toward in-home health assessment is aimed at alleviating the burden on healthcare professionals, the health care system and caregivers. This shift will also further increase the comfort for the patient. Advances in signal acquisition, data storage and communication provide for the collection of reliable and useful in-home physiological data. Artifacts, arising from environmental, experimental and physiological factors, degrade signal quality and render the affected part of the signal useless. The magnitude and frequency of these artifacts significantly increases when data collection is moved from the clinic into the home. Signal processing advances have brought about significant improvement in artifact removal over the past few years. This paper reviews the physiological signals most likely to be recorded in the home, documenting the artifacts which occur most frequently and which have the largest degrading effect. A detailed analysis of current artifact removal techniques will then be presented. An evaluation of the advantages and disadvantages of each of the proposed artifact detection and removal techniques, with particular application to the personal healthcare domain, is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Artifacts and noise removal in electrocardiograms using independent component analysis
Chawla, M. P. S., Verma, H., & Kumar, V. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.037 · Cited by 54
RetractedA New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Sequential Monte Carlo Methods in Practice
(2001) · Springer eBooks · doi:10.1007/978-1-4757-3437-9 · Cited by 7,366
RELATIONS BETWEEN TWO SETS OF VARIATES
HOTELLING, H. (1936) · Biometrika · doi:10.1093/biomet/28.3-4.321 · Cited by 5,263
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
Wavelet Based Empirical Approach to Mitigate the Effect of Motion Artifacts from EEG Signal
Shukla, S., Roy, V., & Prakash, A. (2020) · 2020 IEEE 9th International Conference on Communication Systems and Network Technologies (CSNT) · doi:10.1109/csnt48778.2020.9115761 · Cited by 333
Sweeney, K. T., McLoone, S. F., & Ward, T. E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 300
Self-citationStalin, S., Roy, V., Shukla, P. K., Zaguia, A., Khan, M. M., Shukla, P. K., & Jain, A. (2021) · Mathematical Problems in Engineering · doi:10.1155/2021/2942808 · Cited by 290
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Edge Computing for Smart Health: Context-Aware Approaches, Opportunities, and Challenges
Abdellatif, A. A., Mohamed, A., Chiasserini, C. F., Tlili, M., & Erbad, A. (2019) · IEEE Network · doi:10.1109/mnet.2019.1800083 · Cited by 272
Novel Tactile Sensor Technology and Smart Tactile Sensing Systems: A Review
Zou, L., Ge, C., Wang, Z., Cretu, E., & Li, X. (2017) · Sensors · doi:10.3390/s17112653 · Cited by 271
Neural Decoding of EEG Signals with Machine Learning: A Systematic Review
Saeidi, M., Karwowski, W., Farahani, F. V., Fiok, K., Taiar, R., Hancock, P. A., & Al-Juaid, A. (2021) · Brain Sciences · doi:10.3390/brainsci11111525 · Cited by 258
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
Brainwave-driven human-robot collaboration in construction
Liu, Y., Habibnezhad, M., & Jebelli, H. (2021) · Automation in Construction · doi:10.1016/j.autcon.2021.103556 · Cited by 187
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140
“In addition to activity intensity, several other studies have identified that motion artifacts during exercise were negatively correlated with the accuracy of PPG heart rate–monitoring systems [32,38,46,54-56].”
Chong, J. W., Dao, D. K., Salehizadeh, S. M. A., McManus, D. D., Darling, C. E., Chon, K. H., & Mendelson, Y. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1080-y · Cited by 79
Signal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Metadata
- Authors
- Sweeney, K. T., Ward, T. E., & McLoone, S. F.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 488-500
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2145444715
- Cited by
- 361
- References
- 80
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.