The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Artifact Removal in Physiological Signals—Practices and Possibilities
Abstract
The combination of reducing birth rate and increasing life expectancy continues to drive the demographic shift toward an aging population. This, in turn, places an ever-increasing burden on healthcare due to the increasing prevalence of patients with chronic illnesses and the reducing income-generating population base needed to sustain them. The need to urgently address this healthcare "time bomb" has accelerated the growth in ubiquitous, pervasive, distributed healthcare technologies. The current move from hospital-centric healthcare toward in-home health assessment is aimed at alleviating the burden on healthcare professionals, the health care system and caregivers. This shift will also further increase the comfort for the patient. Advances in signal acquisition, data storage and communication provide for the collection of reliable and useful in-home physiological data. Artifacts, arising from environmental, experimental and physiological factors, degrade signal quality and render the affected part of the signal useless. The magnitude and frequency of these artifacts significantly increases when data collection is moved from the clinic into the home. Signal processing advances have brought about significant improvement in artifact removal over the past few years. This paper reviews the physiological signals most likely to be recorded in the home, documenting the artifacts which occur most frequently and which have the largest degrading effect. A detailed analysis of current artifact removal techniques will then be presented. An evaluation of the advantages and disadvantages of each of the proposed artifact detection and removal techniques, with particular application to the personal healthcare domain, is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Artifacts and noise removal in electrocardiograms using independent component analysis
Chawla, M. P. S., Verma, H., & Kumar, V. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.037 · Cited by 54
RetractedA New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Sequential Monte Carlo Methods in Practice
(2001) · Springer eBooks · doi:10.1007/978-1-4757-3437-9 · Cited by 7,366
RELATIONS BETWEEN TWO SETS OF VARIATES
HOTELLING, H. (1936) · Biometrika · doi:10.1093/biomet/28.3-4.321 · Cited by 5,263
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
A Model for Radar Images and Its Application to Adaptive Digital Filtering of Multiplicative Noise
Frost, V. S., Stiles, J. A., Shanmugan, K. S., & HOLTZMAN, J. C. (1982) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1982.4767223 · Cited by 1,995
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Electroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,812
Relations Between Two Sets of Variates
Hotelling, H. (1936) · Biometrika · doi:10.2307/2333955 · Cited by 1,645
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Measurement of gastrointestinal pH profiles in normal ambulant human subjects
Evans, D. F., Pye, G., Bramley, R., Clark, A. G., Dyson, T. J., & Hardcastle, J. D. (1988) · Gut · doi:10.1136/gut.29.8.1035 · Cited by 1,240
Research Methods in Biomechanics
Robertson, D. G. E., Caldwell, G. E., Hamill, J., Kamen, G., & Whittlesey, S. N. (2014) · Human Kinetics eBooks · doi:10.5040/9781492595809 · Cited by 1,224
Adaptive Filtering: Algorithms and Practical Implementation
Diniz, P. S. R. (2008) · doi:10.1007/978-0-387-68606-6 · Cited by 1,172
Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection
Thakor, N. V., & Zhu, Y.-S. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83591 · Cited by 885
Bayesian filtering for location estimation
Fox, D., Hightower, J., Liao, L., Schulz, D., & Borriello, G. (2003) · IEEE Pervasive Computing · doi:10.1109/mprv.2003.1228524 · Cited by 711
Nocturnal Pulse Oximetry as an Abbreviated Testing Modality for Pediatric Obstructive Sleep Apnea
Brouillette, R. T., Morielli, A., Leimanis, A., Waters, K. A., Luciano, R., & Ducharme, F. M. (2000) · Pediatrics · doi:10.1542/peds.105.2.405 · Cited by 576
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Recognizing faces with PCA and ICA
Draper, B. A., Baek, K., Bartlett, M. S., & Beveridge, J. R. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(03)00077-8 · Cited by 549
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Statisical and Adaptive Signal Processing
Ingle, V. K., Kogon, S. M., & Manolakis, D. G. (2005) · Cited by 512
A Nonlinear Bayesian Filtering Framework for ECG Denoising
Sameni, R., Shamsollahi, M. B., Jutten, C., & Clifford, G. D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897817 · Cited by 502
Independent component analysis for biomedical signals
James, C. J., & Hesse, C. W. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/1/r02 · Cited by 494
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
High-quality recording of bioelectric events: Part 1 Interference reduction, theory and practice
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 427
Jabaudon, D., Sztajzel, J., Sievert, K., Landis, T., & Sztajzel, R. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Berka, C., Levendowski, D. J., Cvetinovic, M. M., Petrovic, M. M., Davis, G., Lumicao, M. N., Zivkovic, V. T., Popovic, M. V., & Olmstead, R. (2004) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1702_3 · Cited by 388
Control of a humanoid robot by a noninvasive brain–computer interface in humans
Bell, C. J., Shenoy, P., Chalodhorn, R., & Rao, R. P. N. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/012 · Cited by 387
Mijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Blind Source Separation and Independent Component Analysis: A Review
Lee, S.-Y. (2005) · International Conference on Neural Information Processing · Cited by 374
Removal of ocular artifacts from electro-encephalogram by adaptive filtering
He, P., Wilson, G., & Russell, C. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344717 · Cited by 364
Investigation into the origin of the noise of surface electrodes
Huigen, E., Peper, A., & Grimbergen, C. A. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344216 · Cited by 353
Source separation using single channel ICA
Davies, M. E., & James, C. J. (2007) · Signal Processing · doi:10.1016/j.sigpro.2007.01.011 · Cited by 301
Functional near-infrared spectroscopy
Bunce, S. C., Izzetoglu, M., Izzetoglu, K., Onaral, B., & Pourrezaei, K. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657788 · Cited by 300
Automatic Removal of Ocular Artifacts in the EEG without an EOG Reference Channel
Gomez-Herrero, G., De Clercq, W., Anwar, H., Kara, O., Egiazarian, K., Van Huffel, S., & Van Paesschen, W. (2006) · Proceedings of the 7th Nordic Signal Processing Symposium - NORSIG 2006 · doi:10.1109/norsig.2006.275210 · Cited by 241
Functional near-infrared spectroscopy
Gajera, J., & Campos, A. (2020) · Radiopaedia.org · doi:10.53347/rid-82780 · Cited by 237
Functional Optical Brain Imaging Using Near-Infrared During Cognitive Tasks
Izzetoglu, K., Bunce, S., Onaral, B., Pourrezaei, K., & Chance, B. (2004) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1702_6 · Cited by 231
Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI
Bonmassar, G. (2002) · NeuroImage · doi:10.1006/nimg.2002.1125 · Cited by 216
Motion Artifact Cancellation in NIR Spectroscopy Using Wiener Filtering
Izzetoglu, M., Devaraj, A., Bunce, S., & Onaral, B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845243 · Cited by 173
Using a low-cost electroencephalograph for task classification in HCI research
Lee, J. C., & Tan, D. S. (2006) · Proceedings of the 19th annual ACM symposium on User interface software and technology · doi:10.1145/1166253.1166268 · Cited by 165
Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering
İzzetoğlu, M., Chitrapu, P. R., Bunce, S. C., & Onaral, B. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-16 · Cited by 164
Electrocardiogram (ECG) Signal Processing
Sörnmo, L., & Laguna, P. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs1482 · Cited by 160
Hint for squint: a computer reliant diagnostic aid for strabismus
Gieszl, L. R., Morris, J. V., & Guyton, D. L. (2005) · Symposium on Computer Applications in Medical Care (SCAMC) · doi:10.1109/scamc.1983.764787 · Cited by 157
Hemodynamics for Brain-Computer Interfaces
Matthews, F., Pearlmutter, B. A., Ward, T. E., Soraghan, C. J., & Markham, C. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408445 · Cited by 154
Self-citationNew horizons in ambulatory electroencephalography
Waterhouse, E. J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213629 · Cited by 129
Gao, J., Zheng, C., & Wang, P. (2010) · Clinical EEG and Neuroscience · doi:10.1177/155005941004100111 · Cited by 126
Adaptive filtering for ECG rejection from surface EMG recordings
Marque, C. K., Bisch, C., Dantas, R., Elayoubi, S., Brosse, V., & Pérot, C. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.10.001 · Cited by 123
Adaptive reduction of motion artifact in the electrocardiogram
Tong, D. A., Bartels, K. A., & Honeyager, K. S. (2002) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1106451 · Cited by 122
Kumar, P. S., Arumuganathan, R., Sivakumar, K., & Vimal, C. (2008) · Cited by 120
Resting energy expenditure and oxygen cost of breathing in patients with cystic fibrosis.
Bell, S. C., Saunders, M. J., Elborn, J. S., & Shale, D. J. (1996) · Thorax · doi:10.1136/thx.51.2.126 · Cited by 109
Fault feature separation using wavelet-ICA filter
Lin, J., & Zhang, A. (2004) · NDT & E International · doi:10.1016/j.ndteint.2004.11.005 · Cited by 105
What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?
Shelley, K. H., Jablonka, D. H., Alian, A. A., Stout, R. G., Rezkanna, H., & Silverman, D. G. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000222477.67637.17 · Cited by 100
Adaptive noise cancelling of motion artifact in stress ECG signals using accelerometer
Raya, M. A. D., & Sison, L. G. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1106637 · Cited by 100
Comparison of methods for adaptive removal of motion artifact
Hamilton, P. S., Curley, M., Aimi, R., & Sae-Hau, C. (2002) · Computers in cardiology · doi:10.1109/cic.2000.898537 · Cited by 93
Extracting multisource brain activity from a single electromagnetic channel
James, C. J., & Lowe, D. (2003) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(03)00037-x · Cited by 92
Indicators of Sleepiness in an ambulatory EEG study of night driving
Papadelis, C. L., Kourtidou‐Papadeli, C., Bamidis, P. D., Chouvarda, I., Koufogiannis, D., Bekiaris, E. D., & Maglaveras, N. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259614 · Cited by 91
Milanesi, M., Martini, N., Vanello, N., Positano, V., Santarelli, M. F., & Landini, L. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0293-8 · Cited by 87
Comparative Review of Techniques for Recording Respiratory Events at Rest and during Deglutition
Tarrant, S. C., Ellis, R. E., Flack, F. C., & Selley, W. G. (1997) · Dysphagia · doi:10.1007/pl00009515 · Cited by 71
Automatic removal of high-amplitude artefacts from single-channel electroencephalograms
Teixeira, A. R., Tomé, A. M., Lang, E. W., Gruber, P., & da Silva, A. M. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.06.003 · Cited by 62
Kalman Filter Based Adaptive Reduction Of Motion Artifact From Photoplethysmographic Signal
Seyedtabaii, S., & Seyedtabaii, L. (2008) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1333655 · Cited by 59
Blinking Artifact Removal in Cognitive EEG Data Using ICA
Li, R., & Príncipe, J. C. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260605 · Cited by 54
Cerebrovascular reactivity and hypercapnic respiratory drive in diabetic autonomic neuropathy
Tantucci, C., Bottini, P., Fiorani, C., Dottorini, M. L., Santeusanio, F., Provinciali, L., Sorbini, C. A., & Casucci, G. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.3.889 · Cited by 54
Application of Kalman Filter to Remove TMS-Induced Artifacts from EEG Recordings
Morbidi, F., Garulli, A., Prattichizzo, D., Rizzo, C., & Rossi, S. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2008.921814 · Cited by 49
Multichannel Techniques for Motion Artifacts Removal from Electrocardiographic Signals
Milanesi, M., Martini, N., Vanello, N., Positano, V., Santarelli, M. F., Paradiso, R., Rossi, D. D., & Landini, L. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260464 · Cited by 46
Fanfulla, F., Mortara, A., Maestri, R., Pinna, G. D., Bruschi, C., Cobelli, F., & Rampulla, C. (1998) · CHEST Journal · doi:10.1378/chest.114.4.1083 · Cited by 44
Artifact removal in EEG using Morphological Component Analysis
Yong, X., Ward, R. K., & Birch, G. E. (2009) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2009.4959591 · Cited by 37
Ambulatory Electrocardiographic Recording
Kowey, P. R., & Kocovic, D. Z. (2003) · Circulation · doi:10.1161/01.cir.0000082930.04238.8c · Cited by 35
New Insights into the RLS Algorithm
Benesty, J., & Gänsler, T. (2004) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/s1110865704310188 · Cited by 30
Berka, C., Levendowski, D. J., Westbrook, P. R., Davis, G., Lumicao, M. N., Olmstead, R. E., Popovic, M. V., Zivkovic, V. T., & Ramsey, C. K. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.597503 · Cited by 26
Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel
Phillips, J. P., Kyriacou, P. A., Jones, D. P., Shelley, K. H., & Langford, R. M. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e328317794d · Cited by 23
Comtois, G., & Mendelson, Y. (2007) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2007.4413301 · Cited by 17
Integrating EEG Models of Cognitive Load with Machine Learning Models of Scientific Problem Solving
Stevens, R., Galloway, T. L., & Berka, C. (2013) · Cited by 17
Intelligent artifact classification for ambulatory physiological signals
Sweeney, K. T., Leamy, D. J., Ward, T. E., & McLoone, S. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627285 · Cited by 16
Self-citation
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
Metadata
- Authors
- Sweeney, K. T., Ward, T. E., & McLoone, S. F.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 488-500
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2145444715
- Cited by
- 361
- References
- 80
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.