A Brain–Computer Interface-Based Vehicle Destination Selection System Using P300 and SSVEP Signals
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this paper, we propose a novel driver-vehicle interface for individuals with severe neuromuscular disabilities to use intelligent vehicles by using P300 and steady-state visual evoked potential (SSVEP) brain-computer interfaces (BCIs) to select a destination and test its performance in the laboratory and real driving conditions. The proposed interface consists of two components: the selection component based on a P300 BCI and the confirmation component based on an SSVEP BCI. Furthermore, the accuracy and selection time models of the interface are built to help analyze the performance of the entire system. Experimental results from 16 participants collected in the laboratory and real driving scenarios show that the average accuracy of the system in the real driving conditions is about 99% with an average selection time of about 26 s. More importantly, the proposed system improves the accuracy of destination selection compared with a single P300 BCI-based selection system, particularly for those participants with relatively low level of accuracy in using the P300 BCI. This study not only provides individuals with severe motor disabilities with an interface to use intelligent vehicles and thus improve their mobility, but also facilitates the research on driver-vehicle interface, multimodal interaction, and intelligent vehicles. Furthermore, it opens an avenue on how cognitive neuroscience may be applied to intelligent vehicles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 1×
“mental arithmetic, or mental rotation [11].”
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“deflection at centroparietal sites at roughly 300 ms after the occurrence of an infrequent target stimulus among frequent nontarget stimuli [9].”
BackgroundControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
Cited by
Noor-A-Rahim, M., Liu, Z., Lee, H., Khyam, M. O., He, J., Pesch, D., Moessner, K., Saad, W., & Poor, H. V. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3173031 · Cited by 737
Feature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces
Hong, K.-S., Khan, M. J., & Hong, M. J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00246 · Cited by 283
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Xu, M., Han, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975614 · Cited by 165
“Previous studies on the hybrid P300-SSVEP BCIs have demonstrated the advantages of such combination [17]–[19], [30], [31].”
BackgroundMondada, L., Karim, M. E., & Mondada, F. (2016) · Swarm Intelligence · doi:10.1007/s11721-016-0127-0 · Cited by 16
Metadata
- Authors
- Fan, X.-A., Bi, L., Teng, T., Ding, H., & Liu, Y.
- Venue
- IEEE Transactions on Intelligent Transportation Systems
- Published
- 2015-02
- Volume
- 16
- Issue
- 1
- Pages
- 274-283
- ISSN
- 1524-9050 (ISSN-L)
- 1558-0016
- OpenAlex
- W2032262437
- Cited by
- 86
- References
- 5
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.