Use of a superconducting instrumentation for biomagnetic measurements performed in a hospital
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A superconducting instrumentation has been set up to perform biomagnetic measurements for screening analysis in one of Rome hospitals. The magnetic detector is a 2nd derivative gradiometer, which can be balanced against both spatially uniform fields and field gradients. The overall noise level is\sim 4 \times 10^{-14}T.Hz-½ in the frequency range 0.5 ÷ 3000Hz. Main efforts are devoted to the recording of magnetocardio-graphic maps of normal and abnormal subjects while a detailed analysis of some segments of the heart cycle is carried on in subjects previously investigated by means of other techniques. Magnetomyograms of normal and abnormal subjects are detected and studied in the frequency domain. Magnetoencephalographic power spectra of various subjects have been mapped as well. Most remarkable results so far collected are presented. Some of the measurements have been performed in the hospital and some in the laboratory, always without the aid of any shielding.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
An introduction to electromyography
Buchthal, F. (1957) · Gyldendal eBooks · Cited by 276
The human magnetoencephalogram: some EEG and related correlations
Reite, M. L., Zimmerman, J. E., EDRICH, J., & Zimmerman, J. T. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90179-6 · Cited by 82
Relationship of the magnetoencephalogram to the electroencephalogram. Normal wake and sleep activity
Hughes, J. R., Hendrix, D. E., Cohen, J., Duffy, F. H., Mayman, C. I., Scholl, M. L., & Cuffin, B. N. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90150-4 · Cited by 62
The Effects of Filtering the His-Purkinje System Electrocardiogram
Berbari, E. J., Lazzara, R., & Scherlag, B. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326513 · Cited by 28
Barbanera, S., Carelli, P., Modean, I., & Romani, G. L. (1978) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/11/4/005 · Cited by 9
Self-citationSuperconducting instrumentation for biomagnetism
Romani, G. L. (1979) · International Journal of Refrigeration · doi:10.1016/0140-7007(79)90086-0 · Cited by 4
Self-citation
Research works printed but not linked: 8
- farrell, 1980, Proc 3rd Int Work shop on Biomag
- tripp, 1980, Proc 3rd Workshop Biomagn
- kramer, 1972, Electromyogr, 12, 19
- hess, 80, Proc 3rd Workshop Biomagn
- barbanera, 1960, Biomag. Measur.etc., Proc 3rd Workshop Biomagn
- karp, 0, Proc 3rd Workshop on Biomag Berlin'80
- barbanera, 1980, Magnetocard. study etc, Proc 3rd Workshop Biomagn
- farrell, 1978, Proc SPIE, 167, 173
Cited by
The Co-Cr (Cobalt-Chromium) system
Ishida, K., & Nishizawa, T. (1990) · Bulletin of Alloy Phase Diagrams · doi:10.1007/bf02843315 · Cited by 130
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
“Although a preliminary magnetic measurement of the PR interval’s MF had been reported in 1978 (116), high-resolution (HR) MCG recordings of the PR segment were carried out independently both with unshielded MCG and in MSR since the early 1980s (27, 33, 117, 118).”
BackgroundMethodSelf-citationBiomagnetic measurements of spontaneous brain activity in epileptic patients
Modena, I., Ricci, G., Barbanera, S., Leoni, R., Romani, G. L., & Carelli, P. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90116-x · Cited by 74
Self-citationA second derivative gradiometer integrated with a dc superconducting interferometer
Carelli, P., & Foglietti, V. (1983) · Journal of Applied Physics · doi:10.1063/1.331757 · Cited by 37
Self-citationApplication of SQUID sensors to the investigation of neural activity in the human brain
Williamson, S. J., & Kaufman, L. (1983) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1983.1062555 · Cited by 38
Localization of biological sources with arrays of superconducting gradiometers
Carelli, P., & Leoni, R. (1986) · Journal of Applied Physics · doi:10.1063/1.336625 · Cited by 27
Self-citationClinical magnetocardiography: 10 Years experience at the catholic university
Fenici, R. R., Melillo, G., & Masselli, M. (1991) · The International Journal of Cardiac Imaging · doi:10.1007/bf01797748 · Cited by 23
“), it was decided to introduce biomagnetometry in a hospital setting [2, 3] in order to investigate whether magnetocardiography could really provide new information of potential diagnostic use [3, 4].”
BackgroundMethodSelf-citationClinical magnetoencephalography
Ricci, G. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455951 · Cited by 22
Magnetic study of the spontaneous brain activity of normal subjects
Carelli, P., Foglietti, V., Modena, I., & Romani, G. L. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455952 · Cited by 21
Self-citationDiscrete spatial filtering with SQUID gradiometers in biomagnetism
Bruno, A. C., Ribeiro, P. C., von der Weid, J. P., & Symko, O. G. (1986) · Journal of Applied Physics · doi:10.1063/1.337008 · Cited by 20
Biomagnetism: An application of squid sensors to medicine and physiology
Romani, G. L. (1984) · Physica B+C · doi:10.1016/0378-4363(84)90147-5 · Cited by 23
Self-citationDigital filter design approach for SQUID gradiometers
Bruno, A. C., & Ribeiro, P. C. (1988) · Journal of Applied Physics · doi:10.1063/1.340983 · Cited by 15
First-gradient balancing of higher-order gradiometers
Vrba, J., & McCubbin, J. A. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455918 · Cited by 13
Optical Atomic Magnetometry for Ultra-Low-Field NMR Detection
Bevilacqua, G., Biancalana, V., Dancheva, Y. V., & Moi, L. (2013) · Annual reports on NMR spectroscopy · doi:10.1016/b978-0-12-404716-7.00003-1 · Cited by 13
Beat to beat surface recording and averaging of his-purkinje activity in man
Erne, S. N., Fenici, R., Hahlbohm, H.-D., Lehmann, H. P., & Trontelj, Z. (1983) · Journal of Electrocardiology · doi:10.1016/s0022-0736(83)80085-5 · Cited by 12
Self-citationHigh-resolution magnetic measurements of human cardiac electrophysiological events
Fenici, R., Romani, G. L., & Erne, S. N. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455927 · Cited by 11
Self-citationNeuromagnetic measurements at hospital: Instrumentation and preliminary tests
Nicolas, P., Duret, D., Teszner, D., & Tuomisto, M. T. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455922 · Cited by 11
A symmetric third order gradiometer without external balancing or magnetocardiography
Bruno, A. C., & Ribeiro, P. C. (1983) · Cryogenics · doi:10.1016/0011-2275(83)90163-7 · Cited by 10
Clinical value of magnetocardiography
Fenici, R., Masselli, M., Lopez, L., & Melillo, G. (1989) · Developments in cardiovascular medicine · doi:10.1007/978-94-009-1081-2_19 · Cited by 10
Self-citationMagnetocardiographically‐Guided Catheter Ablation
FENICI, R. R., COVINO, M., CELLERINO, C., DI LILLO, M., DE FILIPPO, M. C., & MELILLO, G. (1995) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.1995.tb00936.x · Cited by 9
Self-citationMagnetic measurements and modelling for the investigation of the human-heart conduction system
Fenici, R. R., Romani, G. L., & Leoni, R. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455931 · Cited by 8
Self-citationBrisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Self-citationHigh-resolution recordings of thePR segment in magnetocardiography
Erne, S. N., Fenici, R., Hahlbohm, H.-D., Masselli, M., Lehmann, H. P., & Trontelj, Z. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455928 · Cited by 5
Self-citationComputer simulation of magnetic-field patterns from the human cardiac conduction system
Leoni, R., & Romani, G. L. (1982) · Il Nuovo Cimento D · doi:10.1007/bf02451066 · Cited by 4
Self-citationAtrial activity during thePR segment of the MCG
Leifer, M. C., Capos, N., Griffin, J. C., & Wikswo, J. P. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455930 · Cited by 3
Localization of epileptic foci by means of biomagnetic measurements
Barbanera, S., Ricci, G., & Modena, I. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455953 · Cited by 3
Self-citationHigh-resolution recordings of the magnetic activity of the His-Bundle in man
Erne, S. N., Fenici, R., Hahlbohm, H.-D., Lehmann, H. P., & Trontelj, Z. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02457146 · Cited by 3
Self-citationIntroduction to superconducting quantum interference device
Ponselvan, D. Y. S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00013-9 · Cited by 2
Cryogenic Requirements for Medical Instrumentation
Sarwinski, R. E. (1988) · Advances in cryogenic engineering · doi:10.1007/978-1-4613-9874-5_11
Metadata
- Authors
- Barbanera, S., Carelli, P., Fenici, R., Leoni, R., Modena, I., & Romani, G.
- Affiliations
- National Research Council (IT)
- Università Cattolica del Sacro Cuore (IT)
- Venue
- IEEE Transactions on Magnetics
- Published
- 1981-01
- Volume
- 17
- Issue
- 1
- Pages
- 849-852
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2123098875
- Cited by
- 29
- References
- 7
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2013: 1
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- biomagnetic measurement, magnetocardiography, magnetomyography, magnetoencephalography, power spectrum, noise level, hospital screening
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.