The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Advances in Giant Magnetoresistance Biosensors With Magnetic Nanoparticle Tags: Review and Outlook
Abstract
We present a review of giant magnetoresistance (GMR) spin valve sensors designed for detection of magnetic nanoparticles as biomolecular labels (nanotags) in magneto-nano biodetection technology. We discuss the intricacy of magneto-nano biosensor design and show that as few as approximately 14 monodisperse 16-nm superparamagnetic nanoparticles can be detected by submicron spin valve sensors at room temperature without resorting to lock-in (narrow band) detection. GMR biosensors and biochips have been successfully applied to the detection of biological events in the form of both protein and DNA assays with great speed, sensitivity, selectivity, and economy. The limit of molecular detection is well below 10 pM in concentration, and the protein or DNA assay time can be under two hours. The technology is highly scalable to deep multiplex detection of biomarkers in a complex disease, and amenable to integration of microfluidics and CMOS electronics for portable applications. On-chip CMOS circuitry makes a sensor density of 0.1-1 million sensors per square centimeter feasible and affordable. The theoretical and experimental results thus far suggest that magneto-nano biochip-based GMR sensor arrays and nanotags hold great promise in biomedicine, particularly for point-of-care molecular diagnostics of cancer, infectious diseases, radiation injury, cardiac diseases, and other diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giant Magnetoresistance of (001)Fe/(001)Cr Magnetic Superlattices
Baibich, M. N., Broto, J. M., Fert, A., Van Dau, F. N., Petroff, F., Etienne, P., Creuzet, G., Friederich, A., & Chazelas, J. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2472 · Cited by 9,415
Enhanced magnetoresistance in layered magnetic structures with antiferromagnetic interlayer exchange
Binasch, G., Grünberg, P., Saurenbach, F., & Zinn, W. (1989) · Physical Review B · doi:10.1103/physrevb.39.4828 · Cited by 4,347
Large Magnetoresistance at Room Temperature in Ferromagnetic Thin Film Tunnel Junctions
Moodera, J. S., Kinder, L. R., Wong, T. M., & Meservey, R. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3273 · Cited by 3,707
Monodisperse MFe2O4 (M = Fe, Co, Mn) Nanoparticles
Sun, S., Zeng, H., Robinson, D. B., Raoux, S., Rice, P. M., Wang, S. X., & Li, G. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0380852 · Cited by 3,441
Self-citationThermal Fluctuations of a Single-Domain Particle
Brown, W. F. (1963) · Physical Review · doi:10.1103/physrev.130.1677 · Cited by 3,374
Giant magnetic tunneling effect in Fe/Al2O3/Fe junction
Miyazaki, T., & Tezuka, N. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(95)90001-2 · Cited by 1,917
Giant magnetoresistive in soft ferromagnetic multilayers
Dieny, B., Speriosu, V. S., Parkin, S. S. P., Gurney, B. A., Wilhoit, D. R., & Mauri, D. (1991) · Physical Review B · doi:10.1103/physrevb.43.1297 · Cited by 1,885
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Kodama, R. H. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00347-9 · Cited by 1,676
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
Rothkamm, K., & Löbrich, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0830918100 · Cited by 1,645
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Nanomaterials for biosensing applications: a review
Holzinger, M., Le Goff, A., & Cosnier, S. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00063 · Cited by 1,066
Magnetic sensors-A review and recent technologies
Khan, M. A., Sun, J., Li, B., Przybysz, A., & Kosel, J. (2021) · Engineering Research Express · doi:10.1088/2631-8695/ac0838 · Cited by 315
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Self-citationYang, L., Patel, K. D., Rathnam, C., Thangam, R., Hou, Y., Kang, H., & Lee, K. (2022) · Small · doi:10.1002/smll.202104783 · Cited by 81
Metadata
- Authors
- Wang, S. X., & Li, G.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2008-07
- Volume
- 44
- Issue
- 7
- Pages
- 1687-1702
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2162698868
- Cited by
- 340
- References
- 28
- FWCI
- 15.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in Giant Magnetoresistance Biosensors With Magnetic Nanoparticle Tags: Review and Outlook. https://app.cochat.ai/papers/10.1109/tmag.2008.920962
- The paper
- Wang, S. X., & Li, G. (2008). Advances in Giant Magnetoresistance Biosensors With Magnetic Nanoparticle Tags: Review and Outlook. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2008.920962
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.