The Rutgers Master II-new design force-feedback glove
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The Rutgers Master II-ND glove is a haptic interface designed for dextrous interactions with virtual environments. The glove provides force feedback up to 16 N each to the thumb, index, middle, and ring fingertips. It uses custom pneumatic actuators arranged in a direct-drive configuration in the palm. Unlike commercial haptic gloves, the direct-drive actuators make unnecessary cables and pulleys, resulting in a more compact and lighter structure. The force-feedback structure also serves as position measuring exoskeleton, by integrating noncontact Hall-effect and infrared sensors. The glove is connected to a haptic-control interface that reads its sensors and servos its actuators. The interface has pneumatic servovalves, signal conditioning electronics, A/D/A boards, power supply and an imbedded Pentium PC. This distributed computing assures much faster control bandwidth than would otherwise be possible. Communication with the host PC is done over an RS232 line. Comparative data with the CyberGrasp commercial haptic glove is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Burdea, G., & Coiffet, P. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322955950 · Cited by 2,315
Self-citationThe PHANToM Haptic Interface: A Device for Probing Virtual Objects
Massie, T. H., & Salisbury, J. K. (1994) · Dynamic Systems and Control: Volume 1 — Control Theory/Methodology; Robust Control; Applied Nonlinear Control Systems; QFT Designs in Industrial, Government, Academic Settings; Robot Control; Impedance Planning for Robotics; Haptic Interfaces for Virtual Environment/Teleoperator Systems; Intelligent Control Systems; Intelligent Process Control; Neural Networks · doi:10.1115/imece1994-0452 · Cited by 1,372
Force and Touch Feedback for Virtual Reality
Burdea, G. (1996) · Cited by 1,019
Self-citationBurdea, G. (1993) · Cited by 379
Self-citationA virtual-reality-based telerehabilitation system with force feedback
Popescu, V. G., Burdea, G. C., Bouzit, M., & Hentz, V. R. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.826858 · Cited by 244
Self-citationA Stewart Platform-Based System for Ankle Telerehabilitation
Girone, M., Burdea, G., Bouzit, M., Popescu, V., & Deutsch, J. E. (2001) · Autonomous Robots · doi:10.1023/a:1008938121020 · Cited by 236
Self-citationA Portable Dextrous Master with Force Feedback
Burdea, G., Zhuang, J., Roskos, E., Silver, D., & Langrana, N. (1992) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1992.1.1.18 · Cited by 138
Self-citationThe Rutgers Master II-ND force feedback glove
Bouzit, M., Popescu, G. V., Burdea, G., & Boian, R. (2003) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptic.2002.998952 · Cited by 119
Self-citationA Virtual Assembly Design Environment
Jayaram, S., Wang, Y., Jayaram, U., Lyons, K. W., & Hart, P. (2003) · IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr.1999.756948 · Cited by 105
Maximum Finger Force Prediction Using a Planar Simulation of the Middle Finger
Lee, J. W., & Rim, K. (1990) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1990_204_251_02 · Cited by 62
Integration of the Rutgers Master II in a virtual reality simulation
Gómez, D., Burdea, G., & Langrana, N. A. (2002) · IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vrais.1995.512496 · Cited by 52
Self-citation
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Virtual Environments for Motor Rehabilitation: Review
Holden, M. K. (2005) · CyberPsychology & Behavior · doi:10.1089/cpb.2005.8.187 · Cited by 1,154
Lee, L.-H., Braud, T., Zhou, P., Wang, L., Xu, D., Lin, Z., Kumar, A., Bermejo, C., & Hui, P. (2021) · arXiv · doi:10.48550/arxiv.2110.05352 · Cited by 1,088
“The existing works demonstrate various form factors exoskeletons [149], [150], gloves [151], [152], finger addendum [153], [154], smart wristbands [155], by considering numerous mechanisms including air-jets [156], ultrasounds [157]–[159], and laser [160], [161].”
BackgroundWearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
“Pneumatic actuators were also used by Bouzit et al. [154] for the well-known Rutgers Master II, which can provide kinesthetic force up to 16 N to the thumb, index, middle, and ring fingers.”
A Survey of Glove-Based Systems and Their Applications
Dipietro, L., Sabatini, A. M., & Dario, P. (2008) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2008.923862 · Cited by 691
Metadata
- Authors
- Bouzit, M., Burdea, G., Popescu, G., & Boian, R.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2002-06
- Volume
- 7
- Issue
- 2
- Pages
- 256-263
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2150606742
- Cited by
- 570
- References
- 11
- FWCI
- 31.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.