Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 335

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Biomechatronic Design and Control of an Anthropomorphic Artificial Hand for Prosthetic and Robotic Applications

Zollo, Loredana, Roccella, Stefano, Guglielmelli, Eugenio, Carrozza, M. Chiara, Dario, Paolo·2007·IEEE/ASME Transactions on Mechatronics

Abstract

This paper proposes a biomechatronic approach to the design of an anthropomorphic artificial hand able to mimic the natural motion of the human fingers. The hand is conceived to be applied to prosthetics as well as to humanoid and personal robotics; hence, anthropomorphism is a fundamental requirement to be addressed both in the physical aspect and in the functional behavior. In this paper, a biomechatronic approach is addressed to harmonize the mechanical design of the anthropomorphic artificial hand with the design of the hand control system. More in detail, this paper focuses on the control system of the hand and on the optimization of the hand design in order to obtain a human-like kinematics and dynamics. By evaluating the simulated hand performance, the mechanical design is iteratively refined. The mechanical structure and the ratio between number of actuators and number of degrees of freedom (DOFs) have been optimized in order to cope with the strict size and weight constraints that are typical of application of artificial hands to prosthetics and humanoid robotics. The proposed hand has a kinematic structure similar to the natural hand featuring three articulated fingers (thumb, index, and middle finger with 3 DOF for each finger and 1 DOF for the abduction/adduction of the thumb) driven by four dc motors. A special underactuated transmission has been designed that allows keeping the number of motors as low as possible while achieving a self-adaptive grasp, as a result of the passive compliance of the distal DOF of the fingers. A proper hand control scheme has been designed and implemented for the study and optimization of hand motor performance in order to achieve a human-like motor behavior. To this aim, available data on motion of the human fingers are collected from the neuroscience literature in order to derive a reference input for the control. Simulation trials and computer-aided design (CAD) mechanical tools are used to obtain a finger model including its dynamics. Also the closed-loop control system is simulated in order to study the effect of iterative mechanical redesign and to define the final set of mechanical parameters for the hand optimization. Results of the experimental tests carried out for validating the model of the robotic finger, and details on the process of integrated refinement and optimization of the mechanical structure and of the hand motor control scheme are extensively reported in the paper.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmech.2007.901936

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 335

Metadata

Authors
Zollo, L., Roccella, S., Guglielmelli, E., Carrozza, M. C., & Dario, P.
Venue
IEEE/ASME Transactions on Mechatronics
Published
2007-08
Volume
12
Issue
4
Pages
418-429
ISSN
1083-4435 (ISSN-L)
OpenAlex
W2082723833
Cited by
335
References
28
FWCI
13.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biomechatronic Design and Control of an Anthropomorphic Artificial Hand for Prosthetic and Robotic Applications. https://app.cochat.ai/papers/10.1109/tmech.2007.901936
The paper
Zollo, L., Roccella, S., Guglielmelli, E., Carrozza, M. C., & Dario, P. (2007). Biomechatronic Design and Control of an Anthropomorphic Artificial Hand for Prosthetic and Robotic Applications. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2007.901936

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.