The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
Abstract
This paper presents an anthropomorphic prototype hand prosthesis that is intended for use with a multiple-channel myoelectric interface. The hand contains 16 joints, which are differentially driven by a set of five independent actuators. The hand prototype was designed with the minimum number of independent actuators required to provide a set of eight canonical hand postures. This paper describes the design of the prosthesis prototype, demonstrates the hand in the desired eight canonical postures, and experimentally characterizes the force and speed capability of the device. A video is included in the supplementary material that also illustrates the functionality and performance of the hand.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In these devices, cables in the forms of variable length tendons are embedded in soft or rigid skeletons to provide a controlled deformation.[482,483]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [482]
Citations
Cites
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Jones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Robust control of dynamically interacting systems
COLGATE, J. E., & HOGAN, N. (1988) · International Journal of Control · doi:10.1080/00207178808906161 · Cited by 589
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Zollo, L., Roccella, S., Guglielmelli, E., Carrozza, M. C., & Dario, P. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901936 · Cited by 335
The anatomy and mechanics of the human hand.
TAYLOR, C. L., & SCHWARZ, R. J. (1955) · PubMed · Cited by 311
Development of a lightweight and adaptable multiple-axis hand prosthesis
Light, C. M., & Chappell, P. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00017-0 · Cited by 178
Improved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series
Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., & Kuiken, T. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.911817 · Cited by 177
Myoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.
Silcox, D. H., Rooks, M. D., Vogel, R., & Fleming, L. L. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199312000-00007 · Cited by 144
Control of a Six Degree of Freedom Prosthetic Arm After Targeted Muscle Reinnervation Surgery
Miller, L. A., Lipschutz, R. D., Stubblefield, K. A., Lock, B. A., Huang, H., Williams, T. W., Weir, R. F. F., & Kuiken, T. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.05.016 · Cited by 133
Research works printed but not linked: 1
- weir, 2003, Standard Handbook of Biomedical Engineering & Design, 32 1
Cited by
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Piazza, C., Grioli, G., Catalano, M. G., & Bicchi, A. (2019) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105003 · Cited by 332
Additive manufacturing of custom orthoses and prostheses—A review
Chen, R. K., Jin, Y.-A., Wensman, J., & Shih, A. (2016) · Additive Manufacturing · doi:10.1016/j.addma.2016.04.002 · Cited by 292
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Metadata
- Authors
- Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M.
- Affiliations
- Vanderbilt University (US)
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2009-12
- Volume
- 14
- Issue
- 6
- Pages
- 699-706
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2054098571
- Semantic Scholar
- 1336d57e7bc711460d689d7076617eba703f41f7
- Cited by
- 204
- References
- 18
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 6 · 2022: 11 · 2021: 17 · 2020: 9 · 2019: 19 · 2018: 12 · 2017: 16 · 2016: 21 · 2015: 12 · 2014: 22 · 2013: 17 · 2012: 12
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- myoelectric control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation. https://app.cochat.ai/papers/10.1109/tmech.2009.2033113
- The paper
- Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M. (2009). Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2009.2033113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.