On the Design of Miniature Haptic Devices for Upper Extremity Prosthetics
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We have developed three different versions of a multifunction haptic device that can display touch, pressure, vibration, shear force, and temperature to the skin of an upper extremity amputee, especially the one who has undergone targeted nerve reinnervation (TR) surgery. In TR patients, sensation from the reinnervated skin is projected to the missing hand. This paper addresses the design of the mechanical display, the portion responsible for contact, pressure, vibration, and shear force. A variety of different overall design approaches satisfying the design specifications and the performance requirements are considered. The designs of the fully prototyped haptic devices are compared through open-loop frequency response, closed-loop force response, and tapping response in constrained motion. We emphasize the tradeoffs between key design factors, including force capability, workspace, size, bandwidth, weight, and mechanism complexity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“Modality-matched displays of grip pressure have also been developed [5]–[ 8 ].”
Background
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
“To investigate this idea we have created an artificial sense of touch for a prosthesis using a robotic tactile interface (G10 tactor) that is linked to the sensory nervous system through surgically redirected nerves that once served the missing hand (targeted reinnervation) (Kuiken et al., 2004, 2007a; Kim et al., 201…”
BackgroundMethodSelf-citationHaptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“[47] built a tactile device for amputees after targeted nerve reinnervation surgery (Fig.”
BackgroundMethodGonzalez, J., Soma, H., Sekine, M., & Yu, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-33 · Cited by 87
Schofield, J. S., Shell, C. E., Beckler, D. T., Thumser, Z. C., & Marasco, P. D. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00120 · Cited by 68
“We added touch feedback by placing robotic, fourbar haptic pushing devices (touch tactors) on the reinnervated skin at their touch sites (HDT Global, Fredericksburg, VA, United States) (Kim et al., 2010).”
Method
Metadata
- Authors
- Kim, K., Colgate, J. E., Santos-Munne, J. J., Makhlin, A., & Peshkin, M. A.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2010-02
- Volume
- 15
- Issue
- 1
- Pages
- 27-39
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2112656124
- Cited by
- 100
- References
- 4
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.