The DOI matches its Crossref record.
Implementation of the Three-Phase Switched Reluctance Machine System for Motors and Generators
Abstract
This paper presents two three-phase switched reluctance machine systems. One is the dual motors drive for the electric locomotive traction; the other is the variable-speed generator system for wind power applications. The principles of the switched reluctance machine system operated at four quadrants, the scheme of the symmetrical traction at quadrant I and quadrant III, and the scheme of the symmetrical regenerative braking control at quadrant II and quadrant IV, are given. The transient phase current analysis and the energy analysis of the switched reluctance machine system at the operational state of braking or generating are evaluated, and the rotor position and the peak value of the phase current at three different conditions are given. The closed-loop rotor speed control of the main motor, synchronization of the rotor speed, and balance distribution of loads between the main motor and the subordinate motor have been implemented by the fuzzy logic algorithm. The closed-loop output power control of the switched reluctance wind power generator system implemented by regulating the turn-on angle of the main switches with fuzzy logic algorithm and fixed turn-off angle of the main switches is also presented. The major components of the two prototypes are explained in detail. The experimental results of the dual 7.5-kW three-phase 6/4 structure switched reluctance motors (SRMs) parallel drive system prototype are included. It is shown that the maximum difference in the output torque of the two motors at the same given rotor speeds is within 10.00% and the maximum difference in the practical rotor speed of the two motors is within 5.00%. The tested results of three-phase 12/8 structure switched reluctance variable-speed wind power generator system show that the error of the closed-loop output power control is within 2.2%, while the rotor speed range is close to the ratio of 1:3 with the low rotor speed 405 r/min. The average dc line current of the power converter can be utilized as a feedback signal for the actual output torque of SRM drive or a feedback signal for the actual output power of switched reluctance generator system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical Motor Drivelines in Commercial All-Electric Vehicles: A Review
de Santiago, J., Bernhoff, H., Ekergård, B., Eriksson, S., Ferhatovic, S., Waters, R., & Leijon, M. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2011.2177873 · Cited by 669
Gan, C., Wu, J., Sun, Q., Kong, W., Li, H., & Hu, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2837111 · Cited by 286
MMC-Based SRM Drives With Decentralized Battery Energy Storage System for Hybrid Electric Vehicles
Gan, C., Sun, Q., Wu, J., Kong, W., Shi, C., & Hu, Y. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2846622 · Cited by 147
Metadata
- Authors
- Chen, H., & Gu, J. J.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2010-06
- Volume
- 15
- Issue
- 3
- Pages
- 421-432
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2123658044
- Cited by
- 186
- References
- 0
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of the Three-Phase Switched Reluctance Machine System for Motors and Generators. https://app.cochat.ai/papers/10.1109/tmech.2009.2027901
- The paper
- Chen, H., & Gu, J. J. (2010). Implementation of the Three-Phase Switched Reluctance Machine System for Motors and Generators. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2009.2027901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.