Mechanisms of the Anatomically Correct Testbed Hand
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We have built an anatomically correct testbed (ACT) hand with the purpose of understanding the intrinsic biomechanical and control features in human hands that are critical for achieving robust, versatile, and dexterous movements, as well as rich object and world exploration. By mimicking the underlying mechanics and controls of the human hand in a hardware platform, our goal is to achieve previously unmatched grasping and manipulation skills. In this paper, the novel constituting mechanisms, unique muscle to joint relationships, and movement demonstrations of the thumb, index finger, middle finger, and wrist of the ACT Hand are presented. The grasping and manipulation abilities of the ACT Hand are also illustrated. The fully functional ACT Hand platform allows for the possibility to design and experiment with novel control algorithms leading to a deeper understanding of human dexterity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2033113 · Cited by 204
Cited by
Optoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Piazza, C., Grioli, G., Catalano, M. G., & Bicchi, A. (2019) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105003 · Cited by 332
Index Finger of a Human-Like Robotic Hand Using Thin Soft Muscles
Mohd Faudzi, A. A., Ooga, J., Goto, T., Takeichi, M., & Suzumori, K. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2732059 · Cited by 82
Metadata
- Authors
- Deshpande, A. D., Xu, Z., Weghe, M. J. V., Brown, B. H., Ko, J., Chang, L. Y., Wilkinson, D. D., Bidic, S. M., & Matsuoka, Y.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2013-02
- Volume
- 18
- Issue
- 1
- Pages
- 238-250
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2082641899
- Cited by
- 170
- References
- 3
- FWCI
- 15.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.