The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
A Telerobotic System for Transnasal Surgery
Open accessAbstract
Mechanics-based models of concentric tube continuum robots have recently achieved a level of sophistication that makes it possible to begin to apply these robots to a variety of real-world clinical scenarios. Endonasal skull base surgery is one such application, where their small diameter and tentacle like dexterity are particularly advantageous. In this paper we provide the medical motivation for an endonasal surgical robot featuring concentric tube manipulators, and describe our model-based design and teleoperation methods, as well as a complete system incorporating image-guidance. Experimental demonstrations using a laparoscopic training task, a cadaver reachability study, and a phantom tumor resection experiment illustrate that both novice and expert users can effectively teleoperate the system, and that skull base surgeons can use the robot to achieve their objectives in a realistic surgical scenario.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
The prevalence of pituitary adenomas: A systematic review
Ezzat, S., Asa, S. L., Couldwell, W. T., Barr, C. E., Dodge, W. E., Vance, M. L., & McCutcheon, I. E. (2004) · Cancer · doi:10.1002/cncr.20412 · Cited by 1,345
Wampler, C. (1986) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1986.289285 · Cited by 850 · cited 1×
“In our implementation, we adapted the generalized-damped least squares approach to the differential inverse kinematics problem as proposed by Wampler in [35].”
MethodKohler, B. A., Ward, E., McCarthy, B. J., Schymura, M. J., Ries, L. A. G., Eheman, C., Jemal, A., Anderson, R. N., Ajani, U. A., & Edwards, B. K. (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr077 · Cited by 713
Mechanics Modeling of Tendon-Driven Continuum Manipulators
Camarillo, D. B., Milne, C. F., Carlson, C. R., Zinn, M. R., & Salisbury, J. K. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2002311 · Cited by 655
Barker, F. G., Klibanski, A., & Swearingen, B. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030461 · Cited by 506
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
Self-citationEquilibrium Conformations of Concentric-tube Continuum Robots
Rucker, D. C., Webster, R. J., Chirikjian, G. S., & Cowan, N. J. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910367543 · Cited by 217
Self-citationThe Role of Registration in Accurate Surgical Guidance
Fitzpatrick, J. (2010) · Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine · doi:10.1243/09544119jeim589 · Cited by 123
Bajo, A., Goldman, R. E., Wang, L., Fowler, D. L., & Simaan, N. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6224986 · Cited by 106
Ma, B., & Ellis, R. E. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00133-0 · Cited by 97
A bimanual teleoperated system for endonasal skull base surgery
Burgner-Kahrs, J., Swaney, P. J., Rucker, D. C., Gilbert, H. B., Nill, S. T., Russell, P. T., Weaver, K. D., & Webster, R. J., III (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094722 · Cited by 90
Self-citationNavigation systems and platforms in natural orifice translumenal endoscopic surgery (NOTES)
Karimyan, V., Sodergren, M. H., Clark, J., Yang, G., & Darzi, A. W. (2009) · International Journal of Surgery · doi:10.1016/j.ijsu.2009.05.007 · Cited by 67
Planning active cannula configurations through tubular anatomy
Lyons, L. A., Webster, R. J., III, & Alterovitz, R. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509442 · Cited by 63
Waite, K. A., Cioffi, G., Kruchko, C., et al. (2022) · Neuro-Oncology Practice · doi:10.1093/nop/npac025 · Cited by 16
Cited by
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Self-citationA decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Continuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Metadata
- Authors
- Burgner, J., Rucker, D. C., Gilbert, H. B., Swaney, P. J., Russell, P. T., Weaver, K. D., & Webster, R. J.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2014-06
- Volume
- 19
- Issue
- 3
- Pages
- 996-1006
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2050268494
- Cited by
- 294
- References
- 15
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.