The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Equilibrium Conformations of Concentric-tube Continuum Robots
Open accessAbstract
Robots consisting of several concentric, preshaped, elastic tubes can work dexterously in narrow, constrained, and/or winding spaces, as are commonly found in minimally invasive surgery. Previous models of these “active cannulas” assume piecewise constant precurvature of component tubes and neglect torsion in curved sections of the device. In this paper we develop a new coordinate-free energy formulation that accounts for general preshaping of an arbitrary number of component tubes, and which explicitly includes both bending and torsion throughout the device. We show that previously reported models are special cases of our formulation, and then explore in detail the implications of torsional flexibility for the special case of two tubes. Experiments demonstrate that this framework is more descriptive of physical prototype behavior than previous models1 it reduces model prediction error by 82% over the calibrated bending-only model, and 17% over the calibrated transmissional torsion model in a set of experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
Cited by
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Self-citationContinuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Self-citationSoft Robots Modeling: A Structured Overview
Armanini, C., Boyer, F., Mathew, A. T., Duriez, C., & Renda, F. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3231360 · Cited by 336
Continuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
A Telerobotic System for Transnasal Surgery
Burgner, J., Rucker, D. C., Gilbert, H. B., Swaney, P. J., Russell, P. T., Weaver, K. D., & Webster, R. J. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2265804 · Cited by 294
Self-citation
Metadata
- Authors
- Rucker, D. C., Webster, R. J., Chirikjian, G. S., & Cowan, N. J.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2010-04-01
- Volume
- 29
- Issue
- 10
- Pages
- 1263-1280
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2118997958
- Cited by
- 217
- References
- 1
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Equilibrium Conformations of Concentric-tube Continuum Robots. https://app.cochat.ai/papers/10.1177/0278364910367543
- The paper
- Rucker, D. C., Webster, R. J., Chirikjian, G. S., & Cowan, N. J. (2010). Equilibrium Conformations of Concentric-tube Continuum Robots. The International Journal of Robotics Research. https://doi.org/10.1177/0278364910367543
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.