Design and Validation of a Torque-Controllable Knee Exoskeleton for Sit-to-Stand Assistance
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Individuals with poststroke hemiparesis often exhibit mobility deficits, particularly during tasks requiring high lower limb torques. The sit-to-stand transition is consistently marked by asymmetrical weight-bearing between the paretic and unaffected legs. One way to improve characteristics of stroke sit-to-stand may be to provide assistive knee extension torque with a powered exoskeleton. To perform research on the biomechanical effects of assisting sit-to-stand, a unilateral powered knee exoskeleton is required, which can accurately control torque. This paper introduces a novel series elastic actuator capable of producing the full torques and speeds required for sit-to-stand (80 Nm, 3 rad/s). It utilizes a unique transmission configuration with a series fiberglass beam spring that improves torque-control and reduces output impedance. The actuator is incorporated into a unilateral orthosis and a high-level sit-to-stand controller is implemented. A small validation study with three able-bodied subjects performing sit-to-stand is presented, demonstrating the ability to appropriately provide assistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596 · cited 1×
“THERE ARE millions of stroke survivors with chronic hemiparesis living in the United States [1], [2].”
Background
Cited by
Task-agnostic exoskeleton control via biological joint moment estimation
Molinaro, D. D., Scherpereel, K. L., Schonhaut, E. B., Evangelopoulos, G., Shepherd, M. K., & Young, A. J. (2024) · Nature · doi:10.1038/s41586-024-08157-7 · Cited by 107
Self-citationEMG and Joint Angle-Based Machine Learning to Predict Future Joint Angles at the Knee
Coker, J., Chen, H., Schall, M. C., Gallagher, S., & Zabala, M. (2021) · Sensors · doi:10.3390/s21113622 · Cited by 56
Metadata
- Authors
- Shepherd, M. K., & Rouse, E. J.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2017-08
- Volume
- 22
- Issue
- 4
- Pages
- 1695-1704
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2614919192
- Cited by
- 174
- References
- 1
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Validation of a Torque-Controllable Knee Exoskeleton for Sit-to-Stand Assistance. https://app.cochat.ai/papers/10.1109/tmech.2017.2704521
- The paper
- Shepherd, M. K., & Rouse, E. J. (2017). Design and Validation of a Torque-Controllable Knee Exoskeleton for Sit-to-Stand Assistance. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2017.2704521
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.