Design and Validation of a Torque-Controllable Knee Exoskeleton for Sit-to-Stand Assistance
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Individuals with poststroke hemiparesis often exhibit mobility deficits, particularly during tasks requiring high lower limb torques. The sit-to-stand transition is consistently marked by asymmetrical weight-bearing between the paretic and unaffected legs. One way to improve characteristics of stroke sit-to-stand may be to provide assistive knee extension torque with a powered exoskeleton. To perform research on the biomechanical effects of assisting sit-to-stand, a unilateral powered knee exoskeleton is required, which can accurately control torque. This paper introduces a novel series elastic actuator capable of producing the full torques and speeds required for sit-to-stand (80 Nm, 3 rad/s). It utilizes a unique transmission configuration with a series fiberglass beam spring that improves torque-control and reduces output impedance. The actuator is incorporated into a unilateral orthosis and a high-level sit-to-stand controller is implemented. A small validation study with three able-bodied subjects performing sit-to-stand is presented, demonstrating the ability to appropriately provide assistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596 · cited 1×
“THERE ARE millions of stroke survivors with chronic hemiparesis living in the United States [1], [2].”
BackgroundBiomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
The influence of gender and age on disability following ischemic stroke: the Framingham study
Kelly-Hayes, M., Beiser, A., Kase, C. S., Scaramucci, A., D’Agostino, R. B., & Wolf, P. A. (2003) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/s1052-3057(03)00042-9 · Cited by 731 · cited 1×
“THERE ARE millions of stroke survivors with chronic hemiparesis living in the United States [1], [2].”
BackgroundThe RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567 · cited 1×
“The RoboKnee [16] is a torque-controllable knee exoskeleton designed to assist stair ascent and knee-bends while carrying a load, but is not able to be used in the sitting position due to geometric constraints.”
BackgroundCompliant actuation of rehabilitation robots
Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 448 · cited 1×
“Many use a series elastic actuator (SEA) configuration to improve torque-controllability and reduce output impedance [12]–[15].”
BackgroundA Human--Exoskeleton Interface Utilizing Electromyography
Fleischer, C., & Hommel, G. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.926860 · Cited by 412 · cited 1×
“Another approach is to control torque as a function of knee extensor and flexor EMG, acting as an amplifier of the individual muscles [17], [33].”
BackgroundDesign and Control Considerations for High-Performance Series Elastic Actuators
Paine, N., Oh, S., & Sentis, L. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2270435 · Cited by 405
Design and Control of the MINDWALKER Exoskeleton
Wang, S., Wang, L., Meijneke, C., van Asseldonk, E., Hoellinger, T., Cheron, G., Ivanenko, Y., La Scaleia, V., Sylos-Labini, F., Molinari, M., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2365697 · Cited by 380 · cited 1×
“The linkage provides several advantages over a more traditional ball screw approach, in which the nut or screw is directly attached to the output [26], [27].”
BackgroundAn Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376 · cited 1×
“Despite a rich history in powered lower-limb exoskeletons [8]–[10], there are no suitable devices on the market to perform the proposed research.”
BackgroundSeries elastic actuators for high fidelity force control
Pratt, J., Krupp, B., & Morse, C. (2002) · Industrial Robot: An International Journal · doi:10.1108/01439910210425522 · Cited by 343 · cited 1×
“The actuator uses a series spring between the transmission and output [12], [13].”
BackgroundBiomechanics and muscular activity during sit-to-stand transfer
Roebroeck, M. E., Doorenbosch, C. A. M., Harlaar, J., Jacobs, R., & Lankhorst, G. J. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90004-3 · Cited by 299
Symmetrical body-weight distribution training in stroke patients and its effect on fall prevention
Cheng, P.-T., Wu, S.-H., Liaw, M.-Y., Wong, A. M. K., & Tang, F.-T. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26256 · Cited by 287 · cited 2×
“This asymmetry has been linked to an increased risk of falls [3].”
BackgroundClutchable series-elastic actuator: Implications for prosthetic knee design
Rouse, E. J., Mooney, L. M., & Herr, H. M. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914545673 · Cited by 235
Self-citationBiomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217 · cited 1×
“Despite a rich history in powered lower-limb exoskeletons [8]–[10], there are no suitable devices on the market to perform the proposed research.”
BackgroundBiomechanical analysis of sit-to-stand movement in normal and obese subjects
Sibella, F., Galli, M., Romei, M., Montesano, A., & Crivellini, M. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(03)00144-x · Cited by 201
Joint torques during sit-to-stand in healthy subjects and people with Parkinson’s disease
Mak, M. K. Y., Levin, O., Mizrahi, J., & Hui-Chan, C. W. Y. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(02)00191-2 · Cited by 187 · cited 2×
“8 Nm/kg [20]–[23].”
BackgroundA Universal Ankle–Foot Prosthesis Emulator for Human Locomotion Experiments
Caputo, J. M., & Collins, S. H. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4026225 · Cited by 159
Autonomous exoskeleton reduces metabolic cost of human walking
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-151 · Cited by 145
Self-citationTele-impedance based assistive control for a compliant knee exoskeleton
Karavas, N. C., Ajoudani, A., Tsagarakis, N. G., Saglia, J. A., Bicchi, A., & Caldwell, D. G. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.027 · Cited by 139 · cited 2×
“Another approach is to control torque as a function of knee extensor and flexor EMG, acting as an amplifier of the individual muscles [17], [33].”
BackgroundMethodA Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke
Sulzer, J., Roiz, R. A., Peshkin, M., & Patton, J. (2009) · IEEE Transactions on robotics · doi:10.1109/tro.2009.2019788 · Cited by 128 · cited 1×
“SERKA, a flexion-assistance knee exoskeleton with low output impedance, was used with stroke subjects to mitigate stiff-knee gait [18].”
MethodRoy, G., Nadeau, S. M., Gravel, D., Piotte, F., Malouin, F., & McFadyen, B. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.03.007 · Cited by 113 · cited 1×
“2704521 of the torque required for more normative sit-to-stand [5].”
BackgroundKnee extension strength and body weight determine sit-to-stand independence after stroke
Bohannon, R. W. (2007) · Physiotherapy Theory and Practice · doi:10.1080/09593980701209428 · Cited by 89
Power and work produced in different leg muscle groups when rising from a chair
Wretenberg, P. F., & Arborelius, U. P. (1994) · European Journal of Applied Physiology · doi:10.1007/bf00843738 · Cited by 81
A wearable robotic knee orthosis for gait training: a case-series of hemiparetic stroke survivors
Wong, C. K., Bishop, L., & Stein, J. M. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611428235 · Cited by 63 · cited 1×
“The AlterG Bionic Leg [11] is a knee exoskeleton capable of the torques required to aid sit-tostand, but suffers from poor torque controllability, limited speed capability, and substantial mass.”
BackgroundDesign of a series elastic humanoid for the DARPA Robotics Challenge
Knabe, C. S., Seminatore, J., Webb, J., Hopkins, M. A., Furukawa, T., Leonessa, A., & Lattimer, B. Y. (2015) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2015.7363452 · Cited by 47 · cited 1×
“[28].”
Lee, M.-T., Wong, M., Tang, F., Cheng, P.-T., & Lin, P.-S. (1997) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199709000-00011 · Cited by 46 · cited 1×
“In particular, sit-to-stand is commonlymarked by increased postural sway and weight-bearing asymmetry between the paretic and unaffected legs [3], [4].”
BackgroundTorque Control in Legged Locomotion
Zhang, J., Cheah, C., & Collins, S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803766-9.00007-5 · Cited by 42 · cited 1×
“Torque accuracy and torque tracking performance are particularly important; this is a research device, and we must be able to accurately report assistive torques [24].”
BackgroundBiomechanics of sit-to-stand transition after muscle damage
Spyropoulos, G., Tsatalas, T., Tsaopoulos, D. E., Sideris, V., & Giakas, G. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.10.013 · Cited by 38 · cited 1×
“0 rad/s [6], [21].”
Exoskeleton design for functional rehabilitation in patients with neurological disorders and stroke
Zabaleta, H., Bureau, M., Eizmendi, G., Olaiz, E., Medina-Casanovas, J., & Perez, M. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428415 · Cited by 18 · cited 1×
“[32], could be destabilizing, and it was not guaranteed whether it would add or remove energy—that is, aid or resist the movement.”
Background
Cited by
Task-agnostic exoskeleton control via biological joint moment estimation
Molinaro, D. D., Scherpereel, K. L., Schonhaut, E. B., Evangelopoulos, G., Shepherd, M. K., & Young, A. J. (2024) · Nature · doi:10.1038/s41586-024-08157-7 · Cited by 107
Self-citationEMG and Joint Angle-Based Machine Learning to Predict Future Joint Angles at the Knee
Coker, J., Chen, H., Schall, M. C., Gallagher, S., & Zabala, M. (2021) · Sensors · doi:10.3390/s21113622 · Cited by 56
“High- and mid-level controllers can infer user intent and track device states using various sensors including inertial measurement units [20–23], rotary encoders [24], and electromyography (EMG) [9,25].”
Background
Metadata
- Authors
- Shepherd, M. K., & Rouse, E. J.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2017-08
- Volume
- 22
- Issue
- 4
- Pages
- 1695-1704
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2614919192
- Cited by
- 174
- References
- 30
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.