The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Compliant actuation of rehabilitation robots
Abstract
This article discusses the pros and cons of compliant actuation for rehabilitation robots on the example of LOPES, focusing on the cons. After illustrating the bandwidth limitations, a new result has been derived: if stability in terms of passivity of the haptic device is desired, the renderable stiffness is bounded by the stiffness of the SEA's elastic component. In practical experiments with the VMC, the aforementioned limitations affected the control performance. Desired gait modifications were not tracked exactly, because the subjects were able to deviate from the prescribed pattern even in the stiffest possible configuration. Despite the limitations, the practical experiments also demonstrated the general effectiveness of the realization. Manipulation of selected gait parameters is possible, whereby other parameters are left unaffected. This high selectivity is made possible by the low level of undesired interaction torques, which is achieved by elastic decoupling of motor mass and a lightweight exoskeleton. The discrepancy between theoretical bounds and rendered stiffness indicated that healthy subjects might represent a stabilizing component of the coupled system, which could be different for patients. In light of the theoretical stability analysis and with the focus on patients, the LOPES actuation was slightly modified. The robot was equipped with stiffer springs to obtain sufficient stiffness and to ensure stability without relying on stabilizing effects of the human. For this application, the disadvantages of compliant actuation can thus be tolerated or dealt with, and they are small compared with the advantages. Given that a rehabilitation robot, in the first place, is supposed to imitate therapist action, the limitations of bandwidth and stiffness do not pose severe problems. In contrast, safety and backdrivability are highly relevant, and they can be ensured easier with a compliant actuator. Therefore, we conclude that compliant actuation and a lightweight exoskeleton provide effective means to accomplish the desired AAN behavior of a rehabilitation robot. The next step is to evaluate the robot behavior, control performance, and therapeutic effectiveness in patient studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to robotics: Mechanics and control
Merat, F. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087086 · Cited by 2,398
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Self-citationTreadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Effects of Intensity of Rehabilitation After Stroke: A Research Synthesis
Kwakkel, G., Wagenaar, R. C., Koelman, T. W., Lankhorst, G. J., & Koetsier, J. C. (1997) · Stroke · doi:10.1161/01.str.28.8.1550 · Cited by 589
Virtual Model Control: An Intuitive Approach for Bipedal Locomotion
Pratt, J., Chew, C.-M., Torres, A., Dilworth, P., & Pratt, G. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067309 · Cited by 548
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 2×
“The concept, construction, and functionality of these joints are described extensively in [9].”
BackgroundMethodHusemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374
Cai, L. L., Fong, A. J., Otoshi, C. K., Liang, Y., Burdick, J. W., Roy, R. R., & Edgerton, V. R. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.2266-06.2006 · Cited by 344
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“…user intent or invalid sensor inputs [24,67,116,118,121, 136,176,214,239], unstable interactions with the user and environment [60,107,138,181,184,202], actuation failures due to overloading/saturating the actuator [136,170,214], failure of an underactuated system to achieve its desired state,…”
InfluentialSelf-citationAdaptive Command-Filtered Backstepping Control of Robot Arms With Compliant Actuators
Pan, Y., Wang, H., Li, X., & Yu, H. (2018) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2017.2695600 · Cited by 210
Human–Robot Synchrony: Flexible Assistance Using Adaptive Oscillators
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Carrozza, M. C., & Ijspeert, A. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089629 · Cited by 158
Oscillator-based walking assistance: A model-free approach
Ronsse, R., Koopman, B., Vitiello, N., Lenzi, T., De Rossi, S. M. M., van den Kieboom, J., van Asseldonk, E., Carrozza, M. C., van der Kooij, H., & Ijspeert, A. J. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975352 · Cited by 50
Metadata
- Authors
- Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H.
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2008-09
- Volume
- 15
- Issue
- 3
- Pages
- 60-69
- ISSN
- 1070-9932 (ISSN-L)
- OpenAlex
- W2116767351
- Cited by
- 448
- References
- 26
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compliant actuation of rehabilitation robots. https://app.cochat.ai/papers/10.1109/mra.2008.927689
- The paper
- Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008). Compliant actuation of rehabilitation robots. IEEE Robotics & Automation Magazine. https://doi.org/10.1109/mra.2008.927689
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.