The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Estimation of 3-D left ventricular deformation from medical images using biomechanical models
Abstract
The quantitative estimation of regional cardiac deformation from three-dimensional (3-D) image sequences has important clinical implications for the assessment of viability in the heart wall. We present here a generic methodology for estimating soft tissue deformation which integrates image-derived information with biomechanical models, and apply it to the problem of cardiac deformation estimation. The method is image modality independent. The images are segmented interactively and then initial correspondence is established using a shape-tracking approach. A dense motion field is then estimated using a transversely isotropic, linear-elastic model, which accounts for the muscle fiber directions in the left ventricle. The dense motion field is in turn used to calculate the deformation of the heart wall in terms of strain in cardiac specific directions. The strains obtained using this approach in open-chest dogs before and after coronary occlusion, exhibit a high correlation with strains produced in the same animals using implanted markers. Further, they show good agreement with previously published results in the literature. This proposed method provides quantitative regional 3-D estimates of heart deformation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Regional differences in function within noninfarcted myocardium during left ventricular remodeling
Kramer, C. M., Lima, J. A., Reichek, N., Ferrari, V. A., Llaneras, M. R., Palmon, L. C., Yeh, I. T., Tallant, B., & Axel, L. (1993) · Circulation · doi:10.1161/01.cir.88.3.1279 · Cited by 254
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Nonetheless, let us note that they have been applied in the estimation of: cardiac movement [221]–[226], brain shift during surgical operations [227] and lung movement [228], [229].”
BackgroundA review of segmentation methods in short axis cardiac MR images
Petitjean, C., & Dacher, J.-N. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.004 · Cited by 737
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Efficient and generalizable statistical models of shape and appearance for analysis of cardiac MRI
Andreopoulos, A., & Tsotsos, J. K. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.12.003 · Cited by 360
BioImage Suite: An integrated medical image analysis suite: An update
Papademetris, X., Jackowski, M., Rajeevan, N., DiStasio, M., Okuda, H., Constable, R. T., & Staib, L. (2006) · The Insight Journal · doi:10.54294/2g80r4 · Cited by 298
Self-citation
Metadata
- Authors
- Papademetris, X., Sinusas, A. J., Dione, D. P., Constable, R. T., & Duncan, J. S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-07
- Volume
- 21
- Issue
- 7
- Pages
- 786-800
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2159617609
- Cited by
- 212
- References
- 2
- FWCI
- 13.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of 3-D left ventricular deformation from medical images using biomechanical models. https://app.cochat.ai/papers/10.1109/tmi.2002.801163
- The paper
- Papademetris, X., Sinusas, A. J., Dione, D. P., Constable, R. T., & Duncan, J. S. (2002). Estimation of 3-D left ventricular deformation from medical images using biomechanical models. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.801163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.