The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A study of the motion and deformation of the heart due to respiration
Abstract
This paper describes a quantitative assessment of respiratory motion of the heart and the construction of a model of respiratory motion. Three-dimensional magnetic resonance scans were acquired on eight normal volunteers and ten patients. The volunteers were imaged at multiple positions in the breathing cycle between full exhalation and full inhalation while holding their breath. The exhalation volume was segmented and used as a template to which the other volumes were registered using an intensity-based rigid registration algorithm followed by nonrigid registration. The patients were imaged at inhale and exhale only. The registration results were validated by visual assessment and consistency measurements indicating subvoxel registration accuracy. For all subjects, we assessed the nonrigid motion of the heart at the right coronary artery, right atrium, and left ventricle. We show that the rigid-body motion of the heart is primarily in the craniocaudal direction with smaller displacements in the right-left and anterior-posterior directions; this is in agreement with previous studies. Deformation was greatest for the free wall of the right atrium and the left ventricle; typical deformations were 3-4 mm with deformations of up to 7 mm observed in some subjects. Using the registration results, landmarks on the template surface were mapped to their correct positions through the breathing cycle. Principal component analysis produced a statistical model of the motion and deformation of the heart. We discuss how this model could be used to assist motion correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationThe Visualization Toolkit: An Object-Oriented Approach to 3-D Graphics
Schroeder, W. J., & Lorenson, B. (1997) · Cited by 1,882
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
SCHROEDER, W. J., & MARTIN, K. M. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50032-0 · Cited by 1,355
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Wang, Y., Riederer, S. J., & Ehman, R. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330517 · Cited by 491
Magnetic resonance imaging with respiratory gating: techniques and advantages
Ehman, R., McNamara, M., Pallack, M., Hricak, H., & Higgins, C. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.6.1175 · Cited by 299
Atkinson, D., Hill, D. L. G., Stoyle, P. N. R., Summers, P. E., & Keevil, S. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650886 · Cited by 282
Self-citationVoxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Self-citationVoxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Self-citationRespiration‐synchronous fluctuations in stroke volume, heart rate and arterial pressure in humans.
Toska, K., & Eriksen, M. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019958 · Cited by 212
Spherical navigator echoes for full 3D rigid body motion measurement in MRI
Welch, E. B., Manduca, A., Grimm, R. C., Ward, H. A., & Jack Jr., C. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10012 · Cited by 212
Freeborough, P. A., Woods, R. P., & Fox, N. C. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199611000-00030 · Cited by 158
Consistent Linear-Elastic Transformations for Image Matching
Christensen, G. E. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_17 · Cited by 138
Sensitivity Encoded Cardiac MRI
Pruessmann, K. P., Weiger, M., & Boesiger, P. (2001) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-100000143 · Cited by 121
Quantification of left ventricular function with magnetic resonance images acquired in real time
Setser, R. M., Fischer, S., & Lorenz, C. H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200009)12:3<430::aid-jmri8>3.0.co;2-v · Cited by 115
Automatic 3D ASM Construction via Atlas-Based Landmarking and Volumetric Elastic Registration
Frangi, A. F., Niessen, W. J., Rueckert, D., & Schnabel, J. A. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45729-1_7 · Cited by 72
Detecting Failure, Assessing Success
Fitzpatrick, J. M. (2001) · Biomedical engineering series · doi:10.1201/9781420042474.ch6 · Cited by 44
Detecting Failure, Assessing Success
Hajnal, J. V., & Hill, D. (2001) · doi:10.1201/9781420042474-9 · Cited by 4
Self-citation
Cited by
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Self-citationAn Approach to Multimodal Biomedical Image Registration Utilizing Particle Swarm Optimization
Wachowiak, M. P., Smolikova, R., Zheng, Y., Zurada, J. M., & Elmaghraby, A. S. (2004) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2004.826068 · Cited by 389
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
Medical imaging at Guy's Hospital, King's College London
Hawkes, D. J., & Hill, D. L. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815866 · Cited by 260
Self-citationMedrano-Gracia, P., Cowan, B. R., Ambale-Venkatesh, B., Bluemke, D. A., Eng, J., Finn, J. P., Fonseca, C. G., Lima, J. A., Suinesiaputra, A., & Young, A. A. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0056-2 · Cited by 98
Metadata
- Authors
- McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-09
- Volume
- 21
- Issue
- 9
- Pages
- 1142-1150
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2127317088
- Cited by
- 281
- References
- 23
- FWCI
- 13.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.