Intensity-Based Image Registration Using Robust Correlation Coefficients
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can lead to biased registrations. This paper describes an intensity-based image registration technique that uses a robust correlation coefficient as a similarity measure. Relative to the ordinary sample correlation coefficient, the proposed similarity measure reduces the influence of outliers. We also compared the performance of the proposed method with the mutual information-based method. The robust correlation-based method should be useful for image registration in radiotherapy (KeV to MeV X-ray images) and image-guided surgery applications. We have investigated the properties of the proposed method by theoretical analysis, computer simulations, a phantom experiment, and with functional magnetic resonance imaging data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 4×
“In previous investigations, the bias of the sample correlation method for intramodality image registration and that of the MI method for multimodality registration have been studied extensively empirically6 [1], [4], [5], [8], [9].”
MethodInfluentialLehmann, E. L. (1983) · Springer eBooks · doi:10.1007/978-1-4757-2769-2 · Cited by 1,356
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“In a more sophisticated setting when a linear relation is assumed between the signal intensities, the optimal criterion is Cross Correlation (CCor) and Correlation Coe cient (CCoef) [21,80,246].”
BackgroundA review of deep learning-based three-dimensional medical image registration methods
Xiao, H., Teng, X., Liu, C., Li, T., Ren, G., Yang, R., Shen, D., & Cai, J. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-175 · Cited by 77
Metadata
- Authors
- Kim, J., & Fessler, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-11
- Volume
- 23
- Issue
- 11
- Pages
- 1430-1444
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2042436171
- Cited by
- 158
- References
- 3
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intensity-Based Image Registration Using Robust Correlation Coefficients. https://app.cochat.ai/papers/10.1109/tmi.2004.835313
- The paper
- Kim, J., & Fessler, J. A. (2004). Intensity-Based Image Registration Using Robust Correlation Coefficients. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2004.835313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.