Cited by 77Medical Image Segmentation TechniquesAdvanced Radiotherapy TechniquesArtificial Intelligence in Healthcare and Education

A review of deep learning-based three-dimensional medical image registration methods

Open access
Xiao, Haonan, Teng, Xinzhi, Liu, Chenyang, Li, Tian, Ren, Ge, Yang, Ruijie, Shen, Dinggang, Cai, Jing·2021·Quantitative Imaging in Medicine and Surgery

Abstract

Medical image registration is a vital component of many medical procedures, such as image-guided radiotherapy (IGRT), as it allows for more accurate dose-delivery and better management of side effects. Recently, the successful implementation of deep learning (DL) in various fields has prompted many research groups to apply DL to three-dimensional (3D) medical image registration. Several of these efforts have led to promising results. This review summarized the progress made in DL-based 3D image registration over the past 5 years and identify existing challenges and potential avenues for further research. The collected studies were statistically analyzed based on the region of interest (ROI), image modality, supervision method, and registration evaluation metrics. The studies were classified into three categories: deep iterative registration, supervised registration, and unsupervised registration. The studies are thoroughly reviewed and their unique contributions are highlighted. A summary is presented following a review of each category of study, discussing its advantages, challenges, and trends. Finally, the common challenges for all categories are discussed, and potential future research topics are identified.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/qims-21-175

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Previous reviews about deep learning-based medical image registration literature have been published.

    “Though previous reviews about deep learning-based medical image registration literature have been published (19–22), there are still some deficiencies.”
  • Previous reviews lack a summary of public datasets for benchmarking registration algorithms.

    “On one hand, these reviews lack a summary of the public dataset for benchmarking registration algorithms.”

    From A review of deep learning-based deformable medical image registration (2022) · cites this paper as [22]

    The Review Article section says few earlier reviews focused on 3D medical image registration, but does not say they lacked public-dataset summaries. The Statistical analysis section explains why public datasets are useful for fair benchmarking and says this review summarizes them in Table 1; neither passage establishes what earlier reviews omitted. (LLM, conf=0.72)

    Experimental — accuracy not yet measured
  • Some details of the selected literature were missing in previous reviews.

    “On the other hand, some details of the selected literature were missing.”

    From A review of deep learning-based deformable medical image registration (2022) · cites this paper as [22]

    The Review Article section says that few earlier reviews focused on 3D medical image registration, but it does not say they omitted details of their selected literature. Searches for missing or omitted details in previous reviews found no passage addressing that claim. No page number is available in our copy. (LLM, conf=0.72)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 88

  1. Mackie TR, Kapatoes J, Ruchala K, Lu W, Wu C, Olivera G, Forrest L, Tome W, Welsh J, Jeraj R, Harari P, Reckwerdt P, Paliwal B, Ritter M, Keller H, Fowler J, Mehta M. Image guidance for precise conformal radiotherapy. Int J Radiat Oncol Biol Phys 2003;56:89-105.
  2. Fallone BG, Murray B, Rathee S, Stanescu T, Steciw S, Vidakovic S, Blosser E, Tymofichuk D. First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system. Med Phys 2009;36:2084-8.
  3. Zhou Y, Wong OL, Cheung KY, Yu SK, Yuan J. A pilot study of highly accelerated 3D MRI in the head and neck position verification for MR-guided radiotherapy. Quant Imaging Med Surg 2019;9:1255-69.
  4. Yuan J, Wong OL, Zhou Y, Chueng KY, Yu SK. A fast volumetric 4D-MRI with sub-second frame rate for abdominal motion monitoring and characterization in MRI-guided radiotherapy. Quant Imaging Med Surg 2019;9:1303-14.
  5. Troccaz J, Menguy Y, Bolla M, Cinquin P, Vassal P, Laieb N, Desbat L, Dusserre A, Dal Soglio S. Conformal external radiotherapy of prostatic carcinoma: requirements and experimental results. Radiother Oncol 1993;29:176-83.
  6. Verellen D, De Ridder M, Linthout N, Tournel K, Soete G, Storme G. Innovations in image-guided radiotherapy. Nat Rev Cancer 2007;7:949-60.
  7. Dawson LA, Sharpe MB. Image-guided radiotherapy: rationale, benefits, and limitations. Lancet Oncol 2006;7:848-58.
  8. Liang X, Yin FF, Wang C, Cai J. A robust deformable image registration enhancement method based on radial basis function. Quant Imaging Med Surg 2019;9:1315-25.
  9. Christensen GE, Song JH, Lu W, El Naqa I, Low DA. Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry. Med Phys 2007;34:2155-63.
  10. Schreibmann E, Thorndyke B, Li T, Wang J, Xing L. Four-dimensional image registration for image-guided radiotherapy. Int J Radiat Oncol Biol Phys 2008;71:578-86.
  11. Zhang Y, Folkert MR, Huang X, Ren L, Meyer J, Tehrani JN, Reynolds R, Wang J. Enhancing liver tumor localization accuracy by prior-knowledge-guided motion modeling and a biomechanical model. Quant Imaging Med Surg 2019;9:1337-49.
  12. Reed VK, Woodward WA, Zhang L, Strom EA, Perkins GH, Tereffe W, Oh JL, Yu TK, Bedrosian I, Whitman GJ, Buchholz TA, Dong L. Automatic segmentation of whole breast using atlas approach and deformable image registration. Int J Radiat Oncol Biol Phys 2009;73:1493-500.
  13. Schwartz DL, Garden AS, Thomas J, Chen Y, Zhang Y, Lewin J, Chambers MS, Dong L. Adaptive radiotherapy for head-and-neck cancer: initial clinical outcomes from a prospective trial. Int J Radiat Oncol Biol Phys 2012;83:986-93.
  14. Yang D, Brame S, El Naqa I, Aditya A, Wu Y, Goddu SM, Mutic S, Deasy JO, Low DA. Technical note: DIRART- -A software suite for deformable image registration and adaptive radiotherapy research. Med Phys 2011;38:67-77.
  15. Fu Y, Lei Y, Wang T, Curran WJ, Liu T, Yang X. Deep learning in medical image registration: a review. Phys Med Biol 2020;65:20TR01.
  16. Xiao H, Ren G, Cai J. A review on 3D deformable image registration and its application in dose warping. Radiat Med Prot 2020;1:171-8.
  17. Litjens G, Kooi T, Bejnordi BE, Setio AAA, Ciompi F, Ghafoorian M, van der Laak JAWM, van Ginneken B, Sánchez CI. A survey on deep learning in medical image analysis. Med Image Anal 2017;42:60-88.
  18. Ker J, Wang L, Rao J, Lim T. Deep Learning Applications in Medical Image Analysis. IEEE Access 2018;6:9375-89.
  19. Shen D, Wu G, Suk HI. Deep Learning in Medical Image Analysis. Annu Rev Biomed Eng 2017;19:221-48.
  20. Liu Y, Chen X, Wang Z, Wang Z, Ward R, Wang X. Deep learning for pixel-level image fusion: Recent advances and future prospects. Inf Fusion 2018;42:158-73.
  21. Sahiner B, Pezeshk A, Hadjiiski LM, Wang X, Drukker K, Cha KH, Summers RM, Giger ML. Deep learning in medical imaging and radiation therapy. Med Phys 2019;46:e1-e36.
  22. Maier A, Syben C, Lasser T, Riess C. A gentle introduction to deep learning in medical image processing. Z Med Phys 2019;29:86-101.
  23. Guo Y, Liu Y, Oerlemans A, Lao S, Wu S, Lew MS. Deep learning for visual understanding: A review. Neurocomputing 2016;187:27-48.
  24. Jeong J, Wang L, Ji B, Lei Y, Ali A, Liu T, Curran WJ, Mao H, Yang X. Machine-learning based classification of glioblastoma using delta-radiomic features derived from dynamic susceptibility contrast enhanced magnetic resonance images: Introduction. Quant Imaging Med Surg 2019;9:1201-13.
  25. Liu Y, Shi H, Huang S, Chen X, Zhou H, Chang H, Xia Y, Wang G, Yang X. Early prediction of acute xerostomia during radiation therapy for nasopharyngeal cancer based on delta radiomics from CT images. Quant Imaging Med Surg 2019;9:1288-302.
  26. Liang X, Li N, Zhang Z, Yu S, Qin W, Li Y, Chen S, Zhang H, Xie Y. Shading correction for volumetric CT using deep convolutional neural network and adaptive filter. Quant Imaging Med Surg 2019;9:1242-54.
  27. Li W, Li Y, Qin W, Liang X, Xu J, Xiong J, Xie Y. Magnetic resonance image (MRI) synthesis from brain computed tomography (CT) images based on deep learning methods for magnetic resonance (MR)-guided radiotherapy. Quant Imaging Med Surg 2020;10:1223-36.
  28. Li W, Kazemifar S, Bai T, Nguyen D, Weng Y, Li Y, Xia J, Xiong J, Xie Y, Owrangi AM, Jiang SB. Synthesizing CT images from MR images with deep learning: model generalization for different datasets through transfer learning. Biomed Phys Eng Express 2021. [Epub ahead of print]. doi: 10.1088/2057-1976/abe3a7. · DOI
  29. Ren G, Lam SK, Zhang J, Xiao H, Cheung AL, Ho WY, Qin J, Cai J. Investigation of a Novel Deep Learning- Based Computed Tomography Perfusion Mapping Framework for Functional Lung Avoidance Radiotherapy. Front Oncol 2021;11:644703.
  30. Ren G, Zhang J, Li T, Xiao H, Cheung LY, Ho WY, Qin J, Cai J. Deep Learning-Based Computed Tomography Perfusion Mapping (DL-CTPM) for Pulmonary CT-to- Perfusion Translation. Int J Radiat Oncol Biol Phys 2021. [Epub ahead of print]. doi: 10.1016/j.ijrobp.2021.02.032. · DOI
  31. Çiçek Ö, Abdulkadir A, Lienkamp SS, Brox T, Ronneberger O. 3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation. In: Ourselin S, Joskowicz L, Sabuncu MR, Unal G, Wells W, editors. Medical Image Computing and Computer- Assisted Intervention -MICCAI 2016; Cham: Springer International Publishing; 2016:424-32.
  32. Goodfellow I, Pouget-Abadie J, Mirza M, Xu B, Warde-Farley D, Ozair S, Courville A, Bengio Y. Generative adversarial nets. Adv Neural Inf Process Syst 2014;27:2672-80.
  33. You C, Li G, Zhang Y, Zhang X, Shan H, Li M, Ju S, Zhao Z, Zhang Z, Cong W, Vannier MW, Saha PK, Hoffman EA, Wang G. CT Super-Resolution GAN Constrained by the Identical, Residual, and Cycle Learning Ensemble (GAN-CIRCLE). IEEE Trans Med Imaging 2020;39:188-203.
  34. Fu Y, Lei Y, Wang T, Higgins K, Bradley JD, Curran WJ, Liu T, Yang X. LungRegNet: An unsupervised deformable image registration method for 4D-CT lung. Med Phys 2020;47:1763-74.
  35. Fu Y, Lei Y, Zhou J, Wang T, Yu D, Beitler J, Curran W, Liu T, Yang X. Synthetic CT-aided MRI-CT image registration for head and neck radiotherapy. SPIE Medical Imaging 2020. doi: 10.1117/12.2549092. · DOI
  36. Marcus DS, Wang TH, Parker J, Csernansky JG, Morris JC, Buckner RL. Open Access Series of Imaging Studies (OASIS): cross-sectional MRI data in young, middle aged, nondemented, and demented older adults. J Cogn Neurosci 2007;19:1498-507.
  37. Klein A, Andersson J, Ardekani BA, Ashburner J, Avants B, Chiang MC, Christensen GE, Collins DL, Gee J, Hellier P, Song JH, Jenkinson M, Lepage C, Rueckert D, Thompson P, Vercauteren T, Woods RP, Mann JJ, Parsey RV. Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration. Neuroimage 2009;46:786-802.
  38. Klein A, Tourville J. 101 labeled brain images and a consistent human cortical labeling protocol. Front Neurosci 2012;6:171.
  39. Di Martino A, Yan CG, Li Q, Denio E, Castellanos FX, Alaerts K, et al. The autism brain imaging data exchange: towards a large-scale evaluation of the intrinsic brain architecture in autism. Mol Psychiatry 2014;19:659-67.
  40. HD-200 Consortium. The ADHD-200 Consortium: A Model to Advance the Translational Potential of Neuroimaging in Clinical Neuroscience. Front Syst Neurosci 2012;6:62.
  41. Gollub RL, Shoemaker JM, King MD, White T, Ehrlich S, Sponheim SR, et al. The MCIC collection: a shared repository of multi-modal, multi-site brain image data from a clinical investigation of schizophrenia. Neuroinformatics 2013;11:367-88.
  42. Parkinson Progression Marker Initiative. The Parkinson Progression Marker Initiative (PPMI). Prog Neurobiol 2011;95:629-35.
  43. Dagley A, LaPoint M, Huijbers W, Hedden T, McLaren DG, Chatwal JP, Papp KV, Amariglio RE, Blacker D, Rentz DM, Johnson KA, Sperling RA, Schultz AP. Harvard Aging Brain Study: Dataset and accessibility. Neuroimage 2017;144:255-8.
  44. Holmes AJ, Hollinshead MO, O'Keefe TM, Petrov VI, Fariello GR, Wald LL, Fischl B, Rosen BR, Mair RW, Roffman JL, Smoller JW, Buckner RL. Brain Genomics Superstruct Project initial data release with structural, functional, and behavioral measures. Sci Data 2015;2:150031.
  45. Fischl B. FreeSurfer. Neuroimage 2012;62:774-81.
  46. Bakas S, Reyes M, Jakab A, Bauer S, Rempfler M, Crimi A, et al. Identifying the best machine learning algorithms for brain tumor segmentation, progression assessment, and overall survival prediction in the BRATS challenge. arXiv 2018: 1811.02629v3.
  47. Gousias IS, Edwards AD, Rutherford MA, Counsell SJ, Hajnal JV, Rueckert D, Hammers A. Magnetic resonance imaging of the newborn brain: manual segmentation of labelled atlases in term-born and preterm infants. Neuroimage 2012;62:1499-509.
  48. Aubert-Broche B, Griffin M, Pike GB, Evans AC, Collins DL. Twenty new digital brain phantoms for creation of validation image data bases. IEEE Trans Med Imaging 2006;25:1410-6.
  49. Xiao Y, Fortin M, Unsgård G, Rivaz H, Reinertsen I. REtroSpective Evaluation of Cerebral Tumors (RESECT): A clinical database of pre-operative MRI and intra- operative ultrasound in low-grade glioma surgeries. Med Phys 2017;44:3875-82.
  50. Vandemeulebroucke J, Rit S, Kybic J, Clarysse P, Sarrut D. Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs. Med Phys 2011;38:166-78.
  51. Castillo R, Castillo E, Guerra R, Johnson VE, McPhail T, Garg AK, Guerrero T. A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets. Phys Med Biol 2009;54:1849-70.
  52. Castillo E, Castillo R, Martinez J, Shenoy M, Guerrero T. Four-dimensional deformable image registration using trajectory modeling. Phys Med Biol 2010;55:305-27.
  53. Castillo R, Castillo E, Fuentes D, Ahmad M, Wood AM, Ludwig MS, Guerrero T. A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive. Phys Med Biol 2013;58:2861-77.
  54. Jimenez-Del-Toro O, Muller H, Krenn M, Gruenberg K, Taha AA, Winterstein M, et al. Cloud-Based Evaluation of Anatomical Structure Segmentation and Landmark Detection Algorithms: VISCERAL Anatomy Benchmarks. IEEE Trans Med Imaging 2016;35:2459-75.
  55. Stolk J, Putter H, Bakker EM, Shaker SB, Parr DG, Piitulainen E, Russi EW, Grebski E, Dirksen A, Stockley RA, Reiber JH, Stoel BC. Progression parameters for emphysema: a clinical investigation. Respir Med 2007;101:1924-30.
  56. Shieh CC, Gonzalez Y, Li B, Jia X, Rit S, Mory C, Riblett M, Hugo G, Zhang Y, Jiang Z, Liu X, Ren L, Keall P. SPARE: Sparse-view reconstruction challenge for 4D cone-beam CT from a 1-min scan. Med Phys 2019;46:3799-811.
  57. Heller N, Sathianathen N, Kalapara A, Walczak E, Moore K, Kaluzniak H, Rosenberg J, Blake P, Rengel Z, Oestreich M, Dean J, Tradewell M, Shah A, Tejpaul R, Edgerton Z, Peterson M, Raza S, Regmi S, Papanikolopoulos N, Weight C. The KiTS19 Challenge Data: 300 Kidney Tumor Cases with Clinical Context, CT Semantic Segmentations, and Surgical Outcomes. arXiv 2019: 1904.00445.
  58. Simpson AL, Antonelli M, Bakas S, Bilello M, Farahani K, van Ginneken B, Kopp-Schneider A, Landman BA, Litjens G, Menze B, Ronneberger O, Summers RM, Bilic P, Christ PF, Do RKG, Gollub M, Golia-Pernicka J, Heckers SH, Jarnagin WR, McHugo MK, Napel S, Vorontsov E, Maier-Hein L, Cardoso MJ. A large annotated medical image dataset for the development and evaluation of segmentation algorithms. arXiv 2019: 1902.09063.
  59. Roth HR, Lu L, Farag A, Shin HC, Liu J, Turkbey EB, Summers RM. DeepOrgan: Multi-level Deep Convolutional Networks for Automated Pancreas Segmentation. In: Navab N, Hornegger J, Wells WM, Frangi A, editors. Medical Image Computing and Computer-Assisted Intervention --MICCAI 2015; Cham: Springer International Publishing; 2015:556-64.
  60. Yao J, Burns JE, Munoz H, Summers RM. Detection of vertebral body fractures based on cortical shell unwrapping. Med Image Comput Comput Assist Interv 2012;15:509-16.
  61. Madabhushi A, Feldman M. Fused Radiology-Pathology Prostate Dataset. The Cancer Imaging Archive 2016. doi: 10.7937/K9/TCIA.2016.TLPMR1AM. · DOI
  62. Litjens G, Futterer J, Huisman H. Data From Prostate- 3T. The cancer imaging archive. 2015. doi: 10.7937/K9/ TCIA.2015.QJTV5IL5. · DOI
  63. Horn BKP, Schunck BG. Determining Optical-Flow. Artif Intell 1981;17:185-203.
  64. Thirion JP. Image matching as a diffusion process: an analogy with Maxwell's demons. Med Image Anal 1998;2:243-60.
  65. Klein S, Staring M, Murphy K, Viergever MA, Pluim JP. Elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging 2010;29:196-205.
  66. Avants BB, Tustison NJ, Song G, Cook PA, Klein A, Gee JC. A reproducible evaluation of ANTs similarity metric performance in brain image registration. Neuroimage 2011;54:2033-44.
  67. Shen D, Davatzikos C. HAMMER: hierarchical attribute matching mechanism for elastic registration. IEEE Trans Med Imaging 2002;21:1421-39.
  68. Viola P, Wells WM 3rd. Alignment by maximization of mutual information. Int J Comput Vis 1997;24:137-54.
  69. Kim J, Fessler JA. Intensity-based image registration using robust correlation coefficients. IEEE Trans Med Imaging 2004;23:1430-44.
  70. Wu G, Kim M, Wang Q, Munsell BC, Shen D. Scalable High-Performance Image Registration Framework by Unsupervised Deep Feature Representations Learning. IEEE Trans Biomed Eng 2016;63:1505-16.
  71. Simonovsky M, Gutiérrez-Becker B, Mateus D, Navab N, Komodakis N. A deep metric for multimodal registration. In: Ourselin S, Joskowicz L, Sabuncu MR, Unal G, Wells W, editors. Medical Image Computing and Computer- Assisted Intervention -MICCAI 2016; Cham: Springer International Publishing; 2016:10-8.
  72. Sedghi A, O'Donnell LJ, Kapur T, Learned-Miller E, Mousavi P, Wells WM 3rd. Image registration: Maximum likelihood, minimum entropy and deep learning. Med Image Anal 2021;69:101939.
  73. Haskins G, Kruecker J, Kruger U, Xu S, Pinto PA, Wood BJ, Yan P. Learning deep similarity metric for 3D MR- TRUS image registration. Int J Comput Assist Radiol Surg 2019;14:417-25.
  74. Czolbe S, Krause O, Feragen A. DeepSim: Semantic similarity metrics for learned image registration. arXiv 2020: 2011.05735.
  75. Niethammer M, Kwitt R, Vialard FX. Metric Learning for Image Registration. Proc IEEE Comput Soc Conf Comput Vis Pattern Recognit 2019;2019:8455-64.
  76. Ma K, Wang J, Singh V, Tamersoy B, Chang YJ, Wimmer A, Chen T. Multimodal Image Registration with Deep Context Reinforcement Learning. In: Descoteaux M, Maier-Hein L, Franz A, Jannin P, Collins DL, Duchesne S, editors. Medical Image Computing and Computer Assisted Intervention -MICCAI 2017; Cham: Springer International Publishing; 2017:240-8.
  77. Krebs J, Mansi T, Delingette H, Zhang L, Ghesu FC, Miao S, Maier AK, Ayache N, Liao R, Kamen A. Robust non-rigid registration through agent-based action learning. In: Descoteaux M, Maier-Hein L, Franz A, Jannin P, Collins DL, Duchesne S, editors. International Conference on Medical Image Computing and Computer- Assisted Intervention; Cham: Springer International Publishing; 2017:344-52.
  78. Hu J, Luo Z, Wang X, Sun S, Yin Y, Cao K, Song Q, Lyu S, Wu X. End-to-end multimodal image registration via reinforcement learning. Med Image Anal 2021;68:101878.
  79. Cao X, Yang J, Zhang J, Nie D, Kim M, Wang Q, Shen D. Deformable image registration based on similarity-steered CNN regression. In: Descoteaux M, Maier-Hein L, Franz A, Jannin P, Collins DL, Duchesne S, editors. Medical Image Computing and Computer Assisted Intervention - MICCAI 2017; Cham: Springer International Publishing; 2017:300-8.
  80. Teng X, Chen Y, Zhang Y, Ren L. Respiratory deformation registration in 4D-CT/cone beam CT using deep learning. Quant Imaging Med Surg 2021;11:737-48.
  81. Wang J, Zhang M. Deep Learning for Regularization Prediction in Diffeomorphic Image Registration. arXiv 2020: 2011.14229.
  82. Sokooti H, Vos BD, Berendsen F, Ghafoorian M, Yousefi S, Lelieveldt B, Išgum I, Staring M. 3D Convolutional Neural Networks Image Registration Based on Efficient Supervised Learning from Artificial Deformations. arXiv 2019: 1908.10235.
  83. Sokooti H, De Vos B, Berendsen F, Lelieveldt BP, Išgum I, Staring M. Nonrigid image registration using multi- scale 3D convolutional neural networks. In: Descoteaux M, Maier-Hein L, Franz A, Jannin P, Collins DL, Duchesne S, editors. Medical Image Computing and Computer Assisted Intervention -MICCAI 2017; Cham: Springer International Publishing; 2017:232-9.
  84. Eppenhof KAJ, Pluim JPW. Pulmonary CT Registration Through Supervised Learning With Convolutional Neural Networks. IEEE Trans Med Imaging 2019;38:1097-105.
  85. Eppenhof KAJ, Lafarge MW, Moeskops P, Veta M, Pluim JPW. Deformable image registration using convolutional neural networks. Medical Imaging 2018 Image Processing. SPIE 2018. doi: 10.1117/12.2292443. · DOI
  86. Guo H, Kruger M, Xu S, Wood BJ, Yan P. Deep adaptive registration of multi-modal prostate images. Comput Med © Quantitative Imaging in Medicine and Surgery. All rights reserved. Quant Imaging Med Surg 2021;11(12):4895-4916 | https://dx.doi.org/10.21037/qims-21-175 Imaging Graph 2020;84:101769. · DOI
  87. Shen D, Liu T, Peters TM, Staib LH, Essert C, Zhou S, et al., editors. Medical Image Computing and Computer Assisted Intervention -MICCAI 2019; Cham: Springer International Publishing; 2019:645-53. 100. Xu Z, Niethammer M. DeepAtlas: Joint Semi-supervised Learning of Image Registration and Segmentation. In:
  88. Stergios C, Mihir S, Maria V, Guillaume C, Marie-Pierre R, Stavroula M, Nikos P. Linear and deformable image registration with 3d convolutional neural networks. In: Stoyanov D, Taylor Z, Kainz B, Maicas G, Beichel RR, Martel A, et al., editors. Image Analysis for Moving Organ, Breast, and Thoracic Images 2018;11040:13-22. 129. Sun L, Zhang S. Deformable mri-ultrasound registration using 3d convolutional neural network. In: Stoyanov D, Taylor Z, Aylward S, Tavares JMRS, Xiao Y, Simpson A, et al., editors. Simulation, Image Processing, and Ultrasound Systems for Assisted Diagnosis and Navigation; Cham: Springer International Publishing; 2018:152-8. 130. Zhao S, Lau T, Luo J, Chang EI, Xu Y. Unsupervised 3D End-to-End Medical Image Registration With Volume Tweening Network. IEEE J Biomed Health Inform 2020;24:1394-404. 131. Yu H, Zhou X, Jiang H, Kang H, Wang Z, Hara T, Fujita H. Learning 3D non-rigid deformation based on an unsupervised deep learning for PET/CT image registration. SPIE Medical Imaging 2019. doi: 10.1117/12.2512698. 132. Ghosal S, Ray N. Deep deformable registration: Enhancing accuracy by fully convolutional neural net. Pattern Recognit Lett 2017;94:81-6. 133. Sentker T, Madesta F, Werner R. GDL-FIRE4D: Deep Learning-Based Fast 4D CT Image Registration. In: Frangi AF, Schnabel JA, Davatzikos C, Alberola-López C, Fichtinger G, editors. Medical Image Computing and Computer Assisted Intervention -MICCAI 2018; Cham: © Quantitative Imaging in Medicine and Surgery. All rights reserved. Quant Imaging Med Surg 2021;11(12):4895-4916 | https://dx.doi.org/10.21037/qims-21-175 Springer International Publishing; 2018:765-73. 134. Guo Y, Wu X, Wang Z, Pei X, Xu XG. End-to-end unsupervised cycle-consistent fully convolutional network for 3D pelvic CT-MR deformable registration. J Appl Clin Med Phys 2020;21:193-200. 135. Vishnevskiy V, Gass T, Szekely G, Tanner C, Goksel O. Isotropic Total Variation Regularization of Displacements in Parametric Image Registration. IEEE Trans Med Imaging 2017;36:385-95. · DOI

Cited by

Sorted by citations

Authors
Xiao, H., Teng, X., Liu, C., Li, T., Ren, G., Yang, R., Shen, D., & Cai, J.
Affiliations
  • Hong Kong Polytechnic University (HK)
  • Peking University Third Hospital (CN)
  • Korea University (KR)
Corresponding author
Cai, Jing
Venue
Quantitative Imaging in Medicine and Surgery
Published
2021-12
Volume
11
Issue
12
Pages
4895-4916
ISSN
  • 2223-4292 (ISSN-L)
  • 2223-4306
OpenAlex
W3186742534
Cited by
77
References
14
Citations by year
2026: 9 · 2025: 18 · 2024: 13 · 2023: 25 · 2022: 10 · 2021: 2
FWCI
0.78
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Quantitative Imaging in Medicine and Surgery (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion, cc-by-nc-nd)
Funders
  • University Grants Committee
  • Food and Health Bureau
  • Health and Medical Research Fund (06173276, HMRF 06173276)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
medical image registration, three-dimensional image registration, deep learning, image-guided radiotherapy, unsupervised registration, imaging modalities, region of interest

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review