We present a new algorithm to register 3-D preoperative magnetic resonance (MR) images to intraoperative MR images of the brain which have undergone brain shift. This algorithm relies on a robust estimation of the deformation from a sparse noisy set of measured displacements. We propose a new framework to compute the displacement field in an iterative process, allowing the solution to gradually move from an approximation formulation (minimizing the sum of a regularization term and a data error term) to an interpolation formulation (least square minimization of the data error term). An outlier rejection step is introduced in this gradual registration process using a weighted least trimmed squares approach, aiming at improving the robustness of the algorithm. We use a patient-specific model discretized with the finite element method in order to ensure a realistic mechanical behavior of the brain tissue. To meet the clinical time constraint, we parallelized the slowest step of the algorithm so that we can perform a full 3-D image registration in 35 s (including the image update time) on a heterogeneous cluster of 15 personal computers. The algorithm has been tested on six cases of brain tumor resection, presenting a brain shift of up to 14 mm. The results show a good ability to recover large displacements, and a limited decrease of accuracy near the tumor resection cavity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
A survey of MRI-based medical image analysis for brain tumor studies
Bauer, S., Wiest, R., Nolte, L.-P., & Reyes, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/r97 · Cited by 1,036
Brain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
Maier-Hein, L., Mountney, P., Bartoli, A., Elhawary, H., Elson, D., Groch, A., Kolb, A., Rodrigues, M., Sorger, J., Speidel, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.04.003 · Cited by 280
GPU-accelerated elastic 3D image registration for intra-surgical applications
Ruijters, D., ter Haar Romeny, B. M., & Suetens, P. (2011) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.08.014 · Cited by 24
Albi, A., Meola, A., Zhang, F., Kahali, P., Rigolo, L., Tax, C. M. W., Ciris, P. A., Essayed, W. I., Unadkat, P., Norton, I., et al. (2018) · Journal of Neuroimaging · doi:10.1111/jon.12485 · Cited by 19
Self-citation
Metadata
- Authors
- Clatz, O., Delingette, H., Talos, I.-F., Golby, A. J., Kikinis, R., Jolesz, F. A., Ayache, N., & Warfield, S. K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-11
- Volume
- 24
- Issue
- 11
- Pages
- 1417-1427
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2105518334
- Cited by
- 234
- References
- 1
- FWCI
- 21.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust nonrigid registration to capture brain shift from intraoperative MRI. https://app.cochat.ai/papers/10.1109/tmi.2005.856734
- The paper
- Clatz, O., Delingette, H., Talos, I.-F., Golby, A. J., Kikinis, R., Jolesz, F. A., Ayache, N., & Warfield, S. K. (2005). Robust nonrigid registration to capture brain shift from intraoperative MRI. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.856734
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.