Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record.

Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging

Zhisong Wang, Li, Jian, Renbiao Wu·2005·IEEE Transactions on Medical Imaging

Abstract

Currently, the nonadaptive delay-and-sum (DAS) beamformer is extensively used for ultrasound imaging, despite the fact that it has lower resolution and worse interference suppression capability than the adaptive standard Capon beamformer (SCB) if the steering vector corresponding to the signal of interest (SOI) is accurately known. The main problem which restricts the use of SCB, however, is that SCB lacks robustness against steering vector errors that are inevitable in practice. Whenever this happens, the performance of SCB may hecome worse than that of DAS. Therefore, a robust adaptive beamformer is desirable to maintain the robustness of DAS and adaptivity of SCB. In this paper we consider a recent promising robust Capon beamformer (RCB) for ultrasound imaging. We propose two ways of implementing RCB, one based on time delay and the other based on time reversal. RCB extends SCB by allowing the array steering vector to be within an uncertainty set. Hence, it restores the appeal of SCB including its high resolution and superb interference suppression capabilities, and also retains the attractiveness of DAS including its robustness against steering vector errors. The time-delay-based RCB can tolerate the misalignment of data samples and the time-reversal-based RCB can withstand the uncertainty of the Green's function. Both time-delay-based RCB and time-reversal-based RCB can be efficiently computed at a comparable cost to SCB. The excellent performances of the proposed robust adaptive beamforming approaches are demonstrated via a number of simulated and experimental examples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2005.857222

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
Wang, Z., Li, J., & Wu, R.
Venue
IEEE Transactions on Medical Imaging
Published
2005-10
Volume
24
Issue
10
Pages
1308-1322
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2164256114
Cited by
195
References
0
FWCI
8.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging. https://app.cochat.ai/papers/10.1109/tmi.2005.857222
The paper
Wang, Z., Li, J., & Wu, R. (2005). Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.857222

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.