The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Comparison and validation of tissue modelization and statistical classification methods in T1-weighted MR brain images
Open accessAbstract
This paper presents a validation study on statistical nonsupervised brain tissue classification techniques in magnetic resonance (MR) images. Several image models assuming different hypotheses regarding the intensity distribution model, the spatial model and the number of classes are assessed. The methods are tested on simulated data for which the classification ground truth is known. Different noise and intensity nonuniformities are added to simulate real imaging conditions. No enhancement of the image quality is considered either before or during the classification process. This way, the accuracy of the methods and their robustness against image artifacts are tested. Classification is also performed on real data where a quantitative validation compares the methods' results with an estimated ground truth from manual segmentations by experts. Validity of the various classification methods in the labeling of the image as well as in the tissue volume is estimated with different local and global measures. Results demonstrate that methods relying on both intensity and spatial information are more robust to noise and field inhomogeneities. We also demonstrate that partial volume is not perfectly modeled, even though methods that account for mixture classes outperform methods that only consider pure Gaussian classes. Finally, we show that simulated data results can also be extended to real data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.
Geman, S., & Geman, D. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767596 · Cited by 17,949
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Spatial Interaction and the Statistical Analysis of Lattice Systems
Besag, J. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00999.x · Cited by 6,067
The EM Algorithm and Extensions
Kushary, D. (1998) · Technometrics · doi:10.1080/00401706.1998.10485534 · Cited by 5,417
On the Statistical Analysis of Dirty Pictures
Besag, J. (1986) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1986.tb01412.x · Cited by 4,191
A review on image segmentation techniques
Pal, N. R., & Pal, S. K. (1993) · Pattern Recognition · doi:10.1016/0031-3203(93)90135-j · Cited by 3,708
Pattern Classification and Scene Analysis.
Clarke, M. R. B., Duda, R. O., & Hart, P. E. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344977 · Cited by 3,222
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Cited by
Generalized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776
Automated medical image segmentation techniques
Sharma, N., & Aggarwal, L. (2010) · Journal of Medical Physics · doi:10.4103/0971-6203.58777 · Cited by 754
Cortical thickness and central surface estimation
Dahnke, R., Yotter, R. A., & Gaser, C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.050 · Cited by 709
Machine learning framework for early MRI-based Alzheimer's conversion prediction in MCI subjects
Moradi, E., Pepe, A., Gaser, C., Huttunen, H., & Tohka, J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.002 · Cited by 708
An Open Source Multivariate Framework for n-Tissue Segmentation with Evaluation on Public Data
Avants, B. B., Tustison, N. J., Wu, J., Cook, P. A., & Gee, J. C. (2011) · Neuroinformatics · doi:10.1007/s12021-011-9109-y · Cited by 576
Metadata
- Authors
- Cuadra, M. B., Cammoun, L., Butz, T., Cuisenaire, O., & Thiran, J.-P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-12
- Volume
- 24
- Issue
- 12
- Pages
- 1548-1565
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2105947467
- Cited by
- 365
- References
- 47
- FWCI
- 16.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison and validation of tissue modelization and statistical classification methods in T1-weighted MR brain images. https://app.cochat.ai/papers/10.1109/tmi.2005.857652
- The paper
- Cuadra, M. B., Cammoun, L., Butz, T., Cuisenaire, O., & Thiran, J.-P. (2005). Comparison and validation of tissue modelization and statistical classification methods in T1-weighted MR brain images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.857652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.