The DOI matches its Crossref record.
Volumetric breast density estimation from full-field digital mammograms
Open accessAbstract
A method is presented for estimation of dense breast tissue volume from mammograms obtained with full-field digital mammography (FFDM). The thickness of dense tissue mapping to a pixel is determined by using a physical model of image acquisition. This model is based on the assumption that the breast is composed of two types of tissue, fat and parenchyma. Effective linear attenuation coefficients of these tissues are derived from empirical data as a function of tube voltage (kVp), anode material, filtration, and compressed breast thickness. By employing these, tissue composition at a given pixel is computed after performing breast thickness compensation, using a reference value for fatty tissue determined by the maximum pixel value in the breast tissue projection. Validation has been performed using 22 FFDM cases acquired with a GE Senographe 2000D by comparing the volume estimates with volumes obtained by semi-automatic segmentation of breast magnetic resonance imaging (MRI) data. The correlation between MRI and mammography volumes was 0.94 on a per image basis and 0.97 on a per patient basis. Using the dense tissue volumes from MRI data as the gold standard, the average relative error of the volume estimates was 13.6%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Supplemental MRI Screening for Women with Extremely Dense Breast Tissue
Bakker, M. F., de Lange, S. V., Pijnappel, R. M., Mann, R. M., Peeters, P. H. M., Monninkhof, E. M., Emaus, M. J., Loo, C. E., Bisschops, R. H. C., Lobbes, M. B. I., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1903986 · Cited by 702
Self-citationGiger (2018) · doi:10.1016/j.jacr.2017.12.028 · Cited by 634
Unsupervised Deep Learning Applied to Breast Density Segmentation and Mammographic Risk Scoring
Kallenberg, M., Petersen, K., Nielsen, M., Ng, A. Y., Diao, P., Igel, C., Vachon, C. M., Holland, K., Winkel, R. R., Karssemeijer, N., et al. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2532122 · Cited by 439
Self-citationMammographic density, breast cancer risk and risk prediction
Vachon, C. M., van Gils, C. H., Sellers, T. A., Ghosh, K., Pruthi, S., Brandt, K. R., & Pankratz, V. S. (2007) · Breast Cancer Research · doi:10.1186/bcr1829 · Cited by 346
Metadata
- Authors
- van Engeland, S., Snoeren, P. R., Huisman, H., Boetes, C., & Karssemeijer, N.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-03
- Volume
- 25
- Issue
- 3
- Pages
- 273-282
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2145872944
- Cited by
- 238
- References
- 0
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetric breast density estimation from full-field digital mammograms. https://app.cochat.ai/papers/10.1109/tmi.2005.862741
- The paper
- van Engeland, S., Snoeren, P. R., Huisman, H., Boetes, C., & Karssemeijer, N. (2006). Volumetric breast density estimation from full-field digital mammograms. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.862741
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.