The DOI matches its Crossref record.
Investigation of time-of-flight benefit for fully 3-DPET
Abstract
The purpose of this paper is to determine the benefit that can be achieved in image quality for a time-of-flight (TOF) fully three-dimensional (3-D) whole-body positron emission tomography (PET) scanner. We simulate a 3-D whole-body time-of-flight PET scanner with a complete modeling of spatial and energy resolutions. The scanner is based on LaBr3 Anger-logic detectors with which 300ps timing resolution has been achieved. Multiple simulations were performed for 70-cm long uniform cylinders with 27-cm and 35-cm diameters, containing hot spheres (22, 17, 13, and 10-mm diameter) in a central slice and 10-mm diameter hot spheres in a slice at 1/4 axial FOV. Image reconstruction was performed with a list-mode iterative TOF algorithm and data were analyzed after attenuation and scatter corrections for timing resolutions of 300, 600, 1000 ps and non-TOF for varying count levels. The results show that contrast recovery improves slightly with TOF (NEMA NU2-2001 analysis), and improved timing resolution leads to a faster convergence to the maximum contrast value. Detectability for 10-mm diameter hot spheres estimated using a nonprewhitening matched filter (NPW SNR) also improves nonlinearly with TOF. The gain in image quality using contrast and noise measures is proportional to the object diameter and inversely proportional to the timing resolution of the scanner. The gains in NPW SNR are smaller, but they also increase with increasing object diameter and improved timing resolution. The results show that scan times can be reduced in a TOF scanner to achieve images similar to those from a non-TOF scanner, or improved image quality achieved for same scan times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Self-citationState of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Recent developments in time-of-flight PET
Vandenberghe, S., Mikhaylova, E., D’Hoe, E., Mollet, P., & Karp, J. S. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0138-3 · Cited by 368
Recent developments in PET detector technology
Lewellen, T. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/r01 · Cited by 336
Update on time-of-flight PET imaging
Surti, S. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.145029 · Cited by 303
Self-citationImpact of Time-of-Flight on PET Tumor Detection
Kadrmas, D. J., Casey, M. E., Conti, M., Jakoby, B. W., Lois, C., & Townsend, D. W. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.063016 · Cited by 277
State of the art and challenges of time-of-flight PET
Conti, M. (2009) · Physica Medica · doi:10.1016/j.ejmp.2008.10.001 · Cited by 274
Akamatsu, G., Ishikawa, K., Mitsumoto, K., Taniguchi, T., Ohya, N., Baba, S., Abe, K., & Sasaki, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103861 · Cited by 206
Surti, S., Scheuermann, J., El Fakhri, G., Daube-Witherspoon, M. E., Lim, R., Abi-Hatem, N., Moussallem, E., Benard, F., Mankoff, D., & Karp, J. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.086678 · Cited by 104
Self-citation
Metadata
- Authors
- Surti, S., Karp, S., Popescu, L. M., Daube-Witherspoon, E., & Werner, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-05
- Volume
- 25
- Issue
- 5
- Pages
- 529-538
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2138047215
- Cited by
- 166
- References
- 0
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.