The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Deformation-based mapping of volume change from serial brain MRI in the presence of local tissue contrast change
Abstract
This paper is motivated by the analysis of serial structural magnetic resonance imaging (MRI) data of the brain to map patterns of local tissue volume loss or gain over time, using registration-based deformation tensor morphometry. Specifically, we address the important confound of local tissue contrast changes which can be induced by neurodegenerative or neurodevelopmental processes. These not only modify apparent tissue volume, but also modify tissue integrity and its resulting MRI contrast parameters. In order to address this confound we derive an approach to the voxel-wise optimization of regional mutual information (RMI) and use this to drive a viscous fluid deformation model between images in a symmetric registration process. A quantitative evaluation of the method when compared to earlier approaches is included using both synthetic data and clinical imaging data. Results show a significant reduction in errors when tissue contrast changes locally between acquisitions. Finally, examples of applying the technique to map different patterns of atrophy rate in different neurodegenerative conditions is included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
Growth patterns in the developing brain detected by using continuum mechanical tensor maps
Thompson, P. M., Giedd, J. N., Woods, R. P., MacDonald, D., Evans, A. C., & Toga, A. W. (2000) · Nature · doi:10.1038/35004593 · Cited by 850
Fox, N. C., Crum, W. R., Scahill, R. I., Stevens, J. M., Janssen, J. C., & Rossor, M. N. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05408-3 · Cited by 455
Variational Methods for Multimodal Image Matching
Hermosillo, G., Chefd'Hotel, C., & Faugeras, O. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020830525823 · Cited by 388
Cited by
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[347] investigated the use of RegionalMutual Information (RMI).”
MethodMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Metadata
- Authors
- Studholme, C., Drapaca, C., Iordanova, B., & Cardenas, V.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-05
- Volume
- 25
- Issue
- 5
- Pages
- 626-639
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2171272565
- Cited by
- 164
- References
- 5
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.