Symmetric Data Attachment Terms for Large Deformation Image Registration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Nonrigid medical image registration between images that are linked by an invertible transformation is an inherently symmetric problem. The transformation that registers the image pair should ideally be the inverse of the transformation that registers the pair with the order of images interchanged. This property is referred to as symmetry in registration or inverse consistent registration. However, in practical estimation, the available registration algorithms have tended to produce inverse inconsistent transformations when the template and target images are interchanged. In this paper, we propose two novel cost functions in the large deformation diffeomorphic framework that are inverse consistent. These cost functions have symmetric data-attachment terms; in the first, the matching error is measured at all points along the flow between template and target, and in the second, matching is enforced only at the midpoint of the flow between the template and target. We have implemented these cost functions and present experimental results to validate their inverse consistent property and registration accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variational problems on flows of diffeomorphisms for image matching
Dupuis, P., Grenander, U., & Miller, M. I. (1998) · Quarterly of Applied Mathematics · doi:10.1090/qam/1632326 · Cited by 447
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Beg and Khan [77] focused on providing symmetric data terms.”
BackgroundHighly accurate inverse consistent registration: A robust approach
Reuter, M., Rosas, H. D., & Fischl, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.020 · Cited by 1,388
The optimal template effect in hippocampus studies of diseased populations
Avants, B. B., Yushkevich, P., Pluta, J., Minkoff, D., Korczykowski, M., Detre, J., & Gee, J. C. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.062 · Cited by 640
Avoiding asymmetry-induced bias in longitudinal image processing
Reuter, M., & Fischl, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.076 · Cited by 474
Symmetric diffeomorphic modeling of longitudinal structural MRI
Ashburner, J. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00197 · Cited by 304
Neuroanatomy of Apathy and Disinhibition in Frontotemporal Lobar Degeneration
Massimo, L., Powers, C., Moore, P., Vesely, L., Avants, B., Gee, J., Libon, D. J., & Grossman, M. (2009) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000194658 · Cited by 156
“Disinhibition was only mildly related to caregiver distress, and apathy was not significantly related to distress. These results may have differed from ours because the investigators examined clusters of behavior rather than specific behaviors individually.Our study used a novel, symmetric diffeomorphism method of ima…”
ResultNeurocognitive contributions to verbal fluency deficits in frontotemporal lobar degeneration
Libon, D. J., McMillan, C., Gunawardena, D., Powers, C., Massimo, L., Khan, A., Morgan, B., Farag, C., Richmond, L., Weinstein, J., et al. (2009) · Neurology · doi:10.1212/wnl.0b013e3181b2a4f5 · Cited by 122
Self-citationA ready-to-use machine learning tool for symmetric multi-modality registration of brain MRI
Iglesias, J. E. (2023) · Scientific Reports · doi:10.1038/s41598-023-33781-0 · Cited by 64
Adhikari, B. M., Jahanshad, N., Shukla, D., Turner, J., Grotegerd, D., Dannlowski, U., Kugel, H., Engelen, J., Dietsche, B., Krug, A., et al. (2019) · Brain Imaging and Behavior · doi:10.1007/s11682-018-9941-x · Cited by 53
Metadata
- Authors
- Beg, M. F., & Khan, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2007-09
- Volume
- 26
- Issue
- 9
- Pages
- 1179-1189
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2045219179
- Cited by
- 69
- References
- 1
- FWCI
- 12.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.