Optimal Experimental Design for Diffusion Kurtosis Imaging
Abstract
Diffusion kurtosis imaging (DKI) is a new magnetic resonance imaging (MRI) model that describes the non-Gaussian diffusion behavior in tissues. It has recently been shown that DKI parameters, such as the radial or axial kurtosis, are more sensitive to brain physiology changes than the well-known diffusion tensor imaging (DTI) parameters in several white and gray matter structures. In order to estimate either DTI or DKI parameters with maximum precision, the diffusion weighting gradient settings that are applied during the acquisition need to be optimized. Indeed, it has been shown previously that optimizing the set of diffusion weighting gradient settings can have a significant effect on the precision with which DTI parameters can be estimated. In this paper, we focus on the optimization of DKI gradients settings. Commonly, DKI data are acquired using a standard set of diffusion weighting gradients with fixed directions and with regularly spaced gradient strengths. In this paper, we show that such gradient settings are suboptimal with respect to the precision with which DKI parameters can be estimated. Furthermore, the gradient directions and the strengths of the diffusion-weighted MR images are optimized by minimizing the Cramér-Rao lower bound of DKI parameters. The impact of the optimized gradient settings is evaluated, both on simulated as well as experimentally recorded datasets. It is shown that the precision with which the kurtosis parameters can be estimated, increases substantially by optimizing the gradient settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lu, H., Jensen, J. H., Ramani, A., & Helpern, J. A. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1020 · Cited by 420
Cited by
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Self-citationJeurissen, B., Tournier, J.-D., Dhollander, T., Connelly, A., & Sijbers, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.061 · Cited by 1,454
Self-citationEstimation of tensors and tensor‐derived measures in diffusional kurtosis imaging
Tabesh, A., Jensen, J. H., Ardekani, B. A., & Helpern, J. A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22655 · Cited by 460
MR diffusion kurtosis imaging for neural tissue characterization
Wu, E. X., & Cheung, M. M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1506 · Cited by 346
Gliomas: diffusion kurtosis MR imaging in grading
Van Cauter, S., Veraart, J., Sijbers, J., Peeters, R. R., Himmelreich, U., De Keyzer, F., Van Gool, S. W., Van Calenbergh, F., De Vleeschouwer, S., Van Hecke, W., et al. (2012) · Radiology · doi:10.1148/radiol.12110927 · Cited by 340
Self-citation
Metadata
- Authors
- Poot, D. H. J., den Dekker, A. J., Achten, E., Verhoye, M., & Sijbers, J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-03
- Volume
- 29
- Issue
- 3
- Pages
- 819-829
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2163641775
- Cited by
- 208
- References
- 1
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Experimental Design for Diffusion Kurtosis Imaging. https://app.cochat.ai/papers/10.1109/tmi.2009.2037915
- The paper
- Poot, D. H. J., den Dekker, A. J., Achten, E., Verhoye, M., & Sijbers, J. (2010). Optimal Experimental Design for Diffusion Kurtosis Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2009.2037915
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.