General Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Detecting blood vessels in retinal images with the presence of bright and dark lesions is a challenging unsolved problem. In this paper, a novel multiconcavity modeling approach is proposed to handle both healthy and unhealthy retinas simultaneously. The differentiable concavity measure is proposed to handle bright lesions in a perceptive space. The line-shape concavity measure is proposed to remove dark lesions which have an intensity structure different from the line-shaped vessels in a retina. The locally normalized concavity measure is designed to deal with unevenly distributed noise due to the spherical intensity variation in a retinal image. These concavity measures are combined together according to their statistical distributions to detect vessels in general retinal images. Very encouraging experimental results demonstrate that the proposed method consistently yields the best performance over existing state-of-the-art methods on the abnormal retinas and its accuracy outperforms the human observer, which has not been achieved by any of the state-of-the-art benchmark methods. Most importantly, unlike existing methods, the proposed method shows very attractive performances not only on healthy retinas but also on a mixture of healthy and pathological retinas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattern Recognition with Fuzzy Objective Function Algorithms
Bezdek, J. C. (1981) · doi:10.1007/978-1-4757-0450-1 · Cited by 9,881
Kittler, J., Hatef, M., Duin, R. P. W., & Matas, J. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.667881 · Cited by 5,290
Optimal approximations by piecewise smooth functions and associated variational problems
Mumford, D., & Shah, J. (1989) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160420503 · Cited by 5,208
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Prevalence of Age-Related Macular Degeneration in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.564 · Cited by 2,736
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Bronshtein, I. N., Semendyayev, K. A., Musiol, G., & Muehlig, H. (2004) · Springer eBooks · doi:10.1007/978-3-662-05382-9 · Cited by 1,239
The Prevalence of Diabetic Retinopathy Among Adults in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.552 · Cited by 1,148
Cited by
An Ensemble Classification-Based Approach Applied to Retinal Blood Vessel Segmentation
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2205687 · Cited by 1,031
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Trainable COSFIRE filters for vessel delineation with application to retinal images
Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.08.002 · Cited by 713
A Cross-Modality Learning Approach for Vessel Segmentation in Retinal Images
Li, Q., Feng, B., Xie, L., Liang, P., Zhang, H., & Wang, T. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2457891 · Cited by 571
Transforms and Operators for Directional Bioimage Analysis: A Survey
Püspöki, Z., Storath, M., Sage, D., & Unser, M. (2016) · Advances in Anatomy, Embryology and Cell Biology · doi:10.1007/978-3-319-28549-8_3 · Cited by 522
An effective retinal blood vessel segmentation method using multi-scale line detection
Nguyen, U. T. V., Bhuiyan, A., Park, L. A. F., & Ramamohanarao, K. (2013) · Pattern Recognition · doi:10.1016/j.patcog.2012.08.009 · Cited by 479
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Computer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
Joint Segment-Level and Pixel-Wise Losses for Deep Learning Based Retinal Vessel Segmentation
Yan, Z., Yang, X., & Cheng, K.-T. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2828137 · Cited by 428
Robust Retinal Vessel Segmentation via Locally Adaptive Derivative Frames in Orientation Scores
Zhang, J., Dashtbozorg, B., Bekkers, E., Pluim, J. P. W., Duits, R., & ter Haar Romeny, B. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2587062 · Cited by 417
Hierarchical retinal blood vessel segmentation based on feature and ensemble learning
Wang, S., Yin, Y., Cao, G., Wei, B., Zheng, Y., & Yang, G. (2015) · Neurocomputing · doi:10.1016/j.neucom.2014.07.059 · Cited by 390
A Three-Stage Deep Learning Model for Accurate Retinal Vessel Segmentation
Yan, Z., Yang, X., & Cheng, K.-T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2872813 · Cited by 341
An approach to localize the retinal blood vessels using bit planes and centerline detection
Fraz, M. M., Barman, S. A., Remagnino, P., Hoppe, A., Basit, A., Uyyanonvara, B., Rudnicka, A. R., & Owen, C. G. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.08.009 · Cited by 340
Blood Vessel Segmentation of Fundus Images by Major Vessel Extraction and Sub-Image Classification
Roychowdhury, S., Koozekanani, D., & Parhi, K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2335617 · Cited by 336
Retinal vessel segmentation based on Fully Convolutional Neural Networks
Oliveira, A., Pereira, S., & Silva, C. A. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.06.034 · Cited by 299
Iterative Vessel Segmentation of Fundus Images
Roychowdhury, S., Koozekanani, D. D., & Parhi, K. K. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2403295 · Cited by 282
SCS-Net: A Scale and Context Sensitive Network for Retinal Vessel Segmentation
Wu, H., Wang, W., Zhong, J., Lei, B., Wen, Z., & Qin, J. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102025 · Cited by 259
Gihedan, A. (2021) · Scientific Journal for the Faculty of Science-Sirte University · doi:10.37375/sjfssu.v1i1.74
Metadata
- Authors
- Lam, B. S. Y., Gao, Y., & Liew, A. W.-C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-07
- Volume
- 29
- Issue
- 7
- Pages
- 1369-1381
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2084559491
- Cited by
- 275
- References
- 41
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.