The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Fast Semi-Analytical Model-Based Acoustic Inversion for Quantitative Optoacoustic Tomography
Abstract
We present a fast model-based inversion algorithm for quantitative 2-D and 3-D optoacoustic tomography. The algorithm is based on an accurate and efficient forward model, which eliminates the need for regularization in the inversion process while providing modeling flexibility essential for quantitative image formation. The resulting image-reconstruction method eliminates stability problems encountered in previously published model-based techniques and, thus, enables performing image reconstruction in real time. Our model-based framework offers a generalization of the forward solution to more comprehensive optoacoustic propagation models, such as including detector frequency response, without changing the inversion procedure. The reconstruction speed and other algorithmic performances are demonstrated using numerical simulation studies and experimentally on tissue-mimicking optically heterogeneous phantoms and small animals. In the experimental examples, the model-based reconstructions manifested correctly the effect of light attenuation through the objects and did not suffer from the artifacts which usually afflict the commonly used filtered backprojection algorithms, such as negative absorption values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LSQR: An Algorithm for Sparse Linear Equations and Sparse Least Squares
Paige, C. C., & Saunders, M. A. (1982) · ACM Transactions on Mathematical Software · doi:10.1145/355984.355989 · Cited by 4,387
The Numerical Solution of Integral Equations of the Second Kind
ATKINSON, K. E. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9780511626340 · Cited by 1,991
The Radon Transform and Some of Its Applications
Deans, S. R. (1983) · Cited by 1,801
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Multispectral opto-acoustic tomography of deep-seated fluorescent proteins in vivo
Razansky, D., Distel, M., Vinegoni, C., Ma, R., Perrimon, N., Köster, R. W., & Ntziachristos, V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.98 · Cited by 644
Self-citationPhotoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Laufer, J., Delpy, D., Elwell, C., & Beard, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/1/010 · Cited by 319
Discrete-Time Signal Processing
Ream, N. (1977) · Electronics and Power · doi:10.1049/ep.1977.0078 · Cited by 312
The Application of Compressed Sensing for Photo-Acoustic Tomography
Provost, J., & Lesage, F. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2007825 · Cited by 311
Cited by
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Self-citationVolumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309
Self-citation
Metadata
- Authors
- Rosenthal, A., Razansky, D., & Ntziachristos, V.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-06
- Volume
- 29
- Issue
- 6
- Pages
- 1275-1285
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2162418751
- Cited by
- 285
- References
- 16
- FWCI
- 10.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast Semi-Analytical Model-Based Acoustic Inversion for Quantitative Optoacoustic Tomography. https://app.cochat.ai/papers/10.1109/tmi.2010.2044584
- The paper
- Rosenthal, A., Razansky, D., & Ntziachristos, V. (2010). Fast Semi-Analytical Model-Based Acoustic Inversion for Quantitative Optoacoustic Tomography. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2044584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.