A Fast Wavelet-Based Reconstruction Method for Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In this work, we exploit the fact that wavelets can represent magnetic resonance images well, with relatively few coefficients. We use this property to improve magnetic resonance imaging (MRI) reconstructions from undersampled data with arbitrary k-space trajectories. Reconstruction is posed as an optimization problem that could be solved with the iterative shrinkage/thresholding algorithm (ISTA) which, unfortunately, converges slowly. To make the approach more practical, we propose a variant that combines recent improvements in convex optimization and that can be tuned to a given specific k-space trajectory. We present a mathematical analysis that explains the performance of the algorithms. Using simulated and in vivo data, we show that our nonlinear method is fast, as it accelerates ISTA by almost two orders of magnitude. We also show that it remains competitive with TV regularization in terms of image quality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952 · cited 1×
“In accordance with Constraint (i), C′ can take the generic quadratically augmented form C′(w,wn) = C(w) + ‖w −wn‖2Λ−MHM , (14) with the constraint that (Λ−MHM) is positive definite, where the weighting matrix Λ plays the role of a tuning parameter.”
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citationAn iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
A New TwIST: Two-Step Iterative Shrinkage/Thresholding Algorithms for Image Restoration
Bioucas-Dias, J. M., & Figueiredo, M. A. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909319 · Cited by 2,064 · cited 1×
“• generic multistep methods that exploit the result of past iterations to speed up convergence, among them: two-step iterative shrinkage/thresholding [14] (TwIST), Nesterov schemes [15], [16], [17], fast ISTA [18] (FISTA), and monotonic FISTA [19] (MFISTA); • methods that optimize wavelet-subband-dependent parameters…”
MethodBeck, A., & Teboulle, M. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028250 · Cited by 2,004 · cited 1×
“• generic multistep methods that exploit the result of past iterations to speed up convergence, among them: two-step iterative shrinkage/thresholding [14] (TwIST), Nesterov schemes [15], [16], [17], fast ISTA [18] (FISTA), and monotonic FISTA [19] (MFISTA); • methods that optimize wavelet-subband-dependent parameters…”
MethodNonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337 · cited 1×
“For these Fourier precomputations, we used the NUFFT algorithm [30] that is made available at http://www.”
MethodAn EM algorithm for wavelet-based image restoration
Figueiredo, M. A. T., & Nowak, R. D. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.814255 · Cited by 1,219 · cited 4×
“The iterative shrinkage/thresholding algorithm (ISTA) [ 2 ], [13], also known as thresholded Landweber (TL), generates a sequence of estimates that converges to the minimizer of (11) when it is unique.”
MethodInfluentialGradient methods for minimizing composite objective functionPreprint
Nesterov, Y. E. (2007) · RePEc: Research Papers in Economics · Cited by 1,096
Research works printed but not linked: 3
- weiss, 2008, Algorithmes rapides d'optimisation convexe application la restauration d'images et la dtection de changements
- wajer, 2001, Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories, Proc ISMRM, 625
- delattre, 2009, Spline-based variational reconstruction of variable density spiral k-space data with automatic parameter adjustment, Proc ISMRM, 2066
Cited by
Items 101–157 of 157
MRI reconstruction based on Bayesian piecewise sparsity constraint and adaptive 3D transform
Liu, S., Cao, J., Liu, H., & Zhang, K. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107475 · Cited by 6
On Compressive orthonormal Sensing
Zhou, Y., Zhang, H., & Liang, Y. (2016) · Allerton Conference on Communication, Control, and Computing · doi:10.1109/allerton.2016.7852244 · Cited by 5
“However, the first inequality in Theorem 2 implies that our sample complexity is in fact lower than that in [11], although they are on the same order.”
BackgroundYang, G., Lv, J., Chen, Y., Huang, J., & Zhu, J. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2105.01800 · Cited by 5
Model-based deep learning framework for accelerated optical projection tomography
Obando, M., Bassi, A. L., Ducros, N., Mato, G., & Correia, T. (2023) · Scientific Reports · doi:10.1038/s41598-023-47650-3 · Cited by 4
“While typical choices for regularisation are based on total variation 12 and wavelets 13 , the usage of a CNN estimator of aliasing in the image reconstruction has been proposed as a novel way to regularise linear inverse problems.”
MethodLugauer, F., Wetzl, J., Forman, C., Schneider, M., Kiefer, B., Joachim Hornegger, A., Nickel, D. M., & Maier, A. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-017-0670-8 · Cited by 4
“Consequently, the solution of the proximal operator for wavelet regularization is a shrinkage of wavelet coefficients [32].”
BackgroundMillard, C., Hess, A. T., Mailhé, B., & Tanner, J. (2020) · IEEE Open Journal of Signal Processing · doi:10.1109/ojsp.2020.3025228 · Cited by 4
“In [46], which uses different sampling schemes to that employed here, it was found that S-FISTA performed slightly better than FISTA, suggesting that S-FISTA’s relative performance may be particularly dependent on the sampling scheme employed.”
From Nano to Macro: An overview of the IEEE Bio Image and Signal Processing Technical Committee
Aviyente, S., Frangi, A. F., Meijering, E. H. W., Muñoz‐Barrutia, A., Liebling, M., Ville, D. V. D., Olivo‐Marín, J., Kovačević, J., & Unser, M. A. (2023) · IEEE Signal Processing Magazine · doi:10.1109/msp.2023.3242833 · Cited by 8
“The more significant revolution in imaging came with compressed sensing (CS) with theorists [17], [18] and then experimentalists [19], [20] showing the feasibility of image reconstruction from a reduced set of measurements.”
BackgroundSelf-citationComparison of reconstruction algorithm for compressive sensing magnetic resonance imaging
Kong, F. (2017) · Multimedia Tools and Applications · doi:10.1007/s11042-017-4985-2 · Cited by 4
“(d) EWTISTA [24] (e) EWISTARS [26] (a) ISTA [19]”
BackgroundCompressed Sensing in Imaging and Reconstruction - An Insight Review
Sreekala, K., & Kumar, E. K. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-16660-1_76 · Cited by 6
Non-uniform Recovery Guarantees for Binary Measurements and Infinite-Dimensional Compressed Sensing
Thesing, L., & Hansen, A. C. (2021) · Journal of Fourier Analysis and Applications · doi:10.1007/s00041-021-09813-6 · Cited by 4
Gueddari, L. E., Radhakrishna, C. G., Chouzenoux, É., & Ciuciu, P. (2021) · Journal of Imaging · doi:10.3390/jimaging7030058 · Cited by 8
“, the image gradient or a wavelet transform) [16,17].”
BackgroundCompressive sampling in fast wavelet-encoded MRI
Liu, Z., Nutter, B. S., & Mitra, S. D. (2012) · IEEE Southwest Symposium on Image Analysis and Interpretation (SSIAI) · doi:10.1109/ssiai.2012.6202472 · Cited by 4
A review of image reconstruction algorithms in electrical capacitance tomography
Li, K., & Cong, S. (2018) · International Conference on Advanced Computational Intelligence (ICACI) · doi:10.1109/icaci.2018.8377593 · Cited by 4
“5) Other Algorithms: Except for the algorithms introduced above, there are lots of other iterative algorithms, such as iterative Tikhonov methods (ITM) [23], [24], algebraic reconstruction technique (ART) [25], algorithm based on neural network [26], nonquadratic regularizers algorithms include wavelet representations…”
MethodAnalyzing the structure of multidimensional compressed sensing problems through coherencePreprint
Jones, A. D., Adcock, B., & Hansen, A. C. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1610.07497 · Cited by 4
“This image is intended is model a resolution phantom8 which is often used to calibrate MRI devices [16].”
BackgroundInfluentialClosed-Form Approximation of the Total Variation Proximal Operator
Chandler, E. P., Shoushtari, S., Wohlberg, B. E., & Kamilov, U. S. (2025) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2025.3603689 · Cited by 3
“…is another closely related concept originally introduced for de-noising [33], later refined [34], and applied in various imaging inverse problems, including image restoration, MRI reconstruction, 3D CT reconstruction, and computed tomography [35], [36], [37], [38], [39], [40], [41], [42], [43].”
A new parallel MRI image reconstruction model with elastic net regularization
Qiu, B., Chen, W.-S., Chen, B., & Pan, B. (2016) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2016.7727638 · Cited by 3
“For example, wavelet-based reconstruction method [11] [12] [13], vectorial non-local total variation regularization method [14] [15] [16] [17], and augmented lagrangian with variable splitting method [18] [19] [20] was presented.”
MethodRobust online video super-resolution using an efficient alternating projections scheme
Borsoi, R. A. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107575 · Cited by 3
“This technique adds redundancy to W by making it shift invariant while also being strongly related to the TV regularization for image denoising [65], and is now largely used to improve the quality of these kind of methods [66], [32], [67].”
MethodIslam, R. (2020) · International Conference on Sustainable Technologies for Industry 5.0 (STI) · doi:10.1109/sti50764.2020.9350519 · Cited by 3
“For example, sub-band adaptive iterative shrinkage/thresholding algorithm (SISTA), fast iterative shrinkage/thresholding algorithm (FISTA) were developed and applied in CS MRI applications [15] for improved performance.”
MethodCORE ‐ PI : Non‐iterative convolution‐based reconstruction for parallel MRI in the wavelet domain
Shimron, E., WEBB, A. G., & Azhari, H. (2018) · Medical Physics · doi:10.1002/mp.13260 · Cited by 3
Lang, J., Gang, K., & Zhang, C. (2021) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2021.11.013 · Cited by 3
Improved Image Reconstruction Based on Block Compressed Sensing
Wu, Q., Ni, L., & Delong, H. (2012) · Spring Congress on Engineering and Technology · doi:10.1109/scet.2012.6342118 · Cited by 3
“The CS theory has been widely used in signal processing, medical imaging[2-4]etc.”
MethodParallel magnetic resonance imaging acceleration with a hybrid sensing approach
Tran, A. Q., Nguyen, T. A., Doan, P. T., Tran, D.-N., & Tran, D. (2021) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2021116 · Cited by 5
Learning Priors in High-frequency Domain for Inverse Imaging ReconstructionPreprint
He, Z., Zhou, J., Liang, D., Wang, Y., & Liu, Q. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.11148 · Cited by 3
“There are many important applications in medical imaging [1-10], such as magnetic resonance imaging (MRI) and X-ray computed tomography (CT).”
BackgroundSparsity-Driven Statistical Inference for Inverse Problems
Kamilov, U. S. (2015) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-6545 · Cited by 3
Sparse recovery of complex phase-encoded velocity images using iterative thresholding
Roberts, T., Kingsbury, N., & Holland, D. J. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738072 · Cited by 2
“[4] M. Lustig, D. Donoho, and J.M. Pauly, “Sparse MRI: The application of compressed sensing for rapid MR imaging,” Magnetic Resonance in Medicine, vol. 58, no. 6, pp. 1182–1195, 2007.”
BackgroundInfluentialWavelet image decomposition based variable density compressive sampling in MRI
Pejoski, S., & Kafedziski, V. (2011) · Telecommunications Forum (TELFOR) · doi:10.1109/telfor.2011.6143628 · Cited by 2
Statistical Inference of Peroxisome Dynamics
Galitzine, C., Beltran, P. M. J., Cristea, I. M., & Vitek, O. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-89929-9_4 · Cited by 2
Liu, Y., Zhan, Z., Jian-feng Cai, A., Guo, D., Chen, Z., & Qu, X. (2015) · arXiv (Cornell University) · Cited by 2
Li, K., & Holland, D. J. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1603.00816 · Cited by 2
“. People have shown that the same statements would hold true for any positive weighting matrix under certain conditions [19], and the weighted l1 norm approach has been widely implemented [19], [23], [25]. In order to solve the weighted l1 problem, we modify the ISTA by adding a fixed weighting term W inside the l1 nor…”
BackgroundMethodInfluentialfRAKI: k-space deep learning with offline data-universal and online scan-specific priors
Pan, J., Liu, X., Liu, Y., Sun, X., & Pang, Y. (2025) · Neurocomputing · doi:10.1016/j.neucom.2025.130663 · Cited by 1
Using Randomized Nyström Preconditioners to Accelerate Variational Image Reconstruction
Hong, T., Xu, Z., Hu, J., & Fessler, J. A. (2025) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2025.3622903 · Cited by 2
“While deep learning methods often outperform variational methods in many applications, variational image reconstruction[16], [17], [18], [19] offers significant advantages interms of interpretability, theoretical guarantees, and robustness to noise or distribution shifts.”
Adaptive regularization weight selection for compressed sensing MRI reconstruction
Lian, Y., Jiang, Y., & Guo, H. (2025) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2025.110579 · Cited by 1
Hong, T., Villa, U., & Fessler, J. A. (2026) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2026.3655489 · Cited by 2
“Traditional hand-crafted regularizers include wavelets [8], total variation (TV) [7], [9], combinations of wavelets and TV [2], [10], dictionary learning [11], [12], and low-rank models [13], to name a few.”
Under-Sampled Reconstruction Techniques for Accelerated Magnetic Resonance Imaging
Kayvanrad, M. H. (2013) · Scholarship@Western (Western University) · Cited by 1
Stable nonuniform sampling with weighted Fourier frames and recovery in arbitrary spaces
Adcock, B., Gatarić, M., & Hansen, A. C. (2015) · International Conference on Sampling Theory and Applications · doi:10.1109/sampta.2015.7148860 · Cited by 1
“NUGS is closest to the efficient algorithm from the recent work of Guerquin–Kern, Häberlin, Pruessmann and Unser [12] where the equivalent model is considered for wavelet reconstruction spaces.”
MethodMathew, R. S., & Paul, J. S. (2017) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2017.2707979 · Cited by 1
“Additional improvements can be obtained with sparsity enforcing regularization such as adaptive thresholding in wavelet domain [24], [25], or spatially dependent TV based regularization in finite difference domain [26].”
He, W., & Zhao, L. (2022) · International Journal of Biomedical Imaging · doi:10.1155/2022/7251674 · Cited by 1
WNN in Image Restoration for Industrial Applications
Jose, A., & Subramaniam, K. (2016) · International Journal of Computer Applications · doi:10.5120/ijca2016912238 · Cited by 1
“To make the approach more practical, Guerquin-Kern et al [5] proposed a variant that combines recent improvements in convex optimization and that can be tuned to a given specific k-space trajectory presented a mathematical analysis that explains the performance of the algorithms.”
MethodMR image reconstruction from undersampled measurements using union-of-subspaces
Wang, Y., Zhao, D., Ma, S., & Du, H. (2017) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei.2017.8302025 · Cited by 1
“Compressed sensing (CS) [1], [2], [3], [17] based MRI reconstruction methods exploit the sparsity of the MR image to obtain high quality reconstruction image from d [4], [5], [6].”
MethodContinuous Compressed Sensing of Inelastic and Quasielastic Helium Atom Scattering SpectraPreprint
Jones, A., Tamtögl, A., Calvo‐Almazán, I., & Hansen, A. C. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1510.00555 · Cited by 1
“[6, 7] has long been associated with Nuclear Magnetic Resonance (NMR) based applications such as Magnetic Resonance Imaging [8, 9] and NMR Spectroscopy [10].”
BackgroundSparsity promoting optimization in quantum mechanical signal processing
Compton, R. (2012) · eScholarship (California Digital Library)
A complex-valued majorize-minimize memory gradient method with application to parallel MRI
Florescu, A., Chouzenoux, É., Pesquet, J.-C., Ciuciu, P., & Ciochină, S. (2013) · HAL
MRI using field dynamics for position sensing and motion correction
Haeberlin, M. (2014) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-010398263
Splitting methods and primal-dual formulations for higher order imaging models
Calatroni, L. (2013)
Two-level Bregman method for MRI reconstruction with graph regularized sparse coding
Liu, Q., Lu, H., & Zhang, M. (2016) · Transactions of Tianjin University · doi:10.1007/s12209-016-2581-4
Joy, A., & Paul, J. S. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-981-32-9088-4_5
Recovering Wavelet Coefficients from Binary Samples Using Fast Transforms
Antun, V. (2022) · SIAM Journal on Scientific Computing · doi:10.1137/21m1427188
Hierarchical prior based sparse representation for compressed sensing MRI
Cao, J., Liu, S., & Zhang, K. (2021) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin52536.2021.9566016
On Seismicity Driven Chaotic Model by DWT
Wang, F.-T., Chen, C., Lee, J. C.-Y., Chang, S., Lin, C., Tin, H.-W., & Kao, W.-J. (2014) · Springer proceedings in physics · doi:10.1007/978-3-319-03749-3_27
Shahalinejad, S., Bahador, A., & Niapour, A. (2022) · Alborz University Medical Journal · doi:10.61186/aums.12.1.60
Theoretical Guarantees of Recovery Algorithms for Ternary Sparse Signals
Liu, H., & Li, C. (2025) · Numerical Mathematics Theory Methods and Applications · doi:10.4208/nmtma.oa-2025-0014
Compressed Sensing in MRI : optimization-based design of k-space filling curves for accelerated MRI
Lazarus, C. (2018) · theses.fr (ABES) · doi:10.70675/0a2c3fdcze241z40d9zbef5z8f3a99ed9776 · Cited by 7
Reuzé, S. (2018) · theses.fr (ABES) · doi:10.70675/283aded3z5687z40c8z93bfzaea2941d657c · Cited by 4
Multi-nuclear RMN in Spectroscopy and Imagery at very high magnetic fields
Stout, J. A. (2019) · theses.fr (ABES) · doi:10.70675/e54ad71az8f87z4c42z9f45z1ddc59f3aac1
CoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout
Song, T., Li, Z., Li, Z., Zhong, W., Liao, C., Yang, Y., Guo, H., Wu, W., & Tian, Q. (2026) · Medical Image Analysis · doi:10.1016/j.media.2026.104337
URG-MRI: Unpaired reference guided MRI reconstruction
Chen, X. M., Gu, J., Jia, F., Ying, S., & Ma, L. (2026) · Expert Systems with Applications · doi:10.1016/j.eswa.2026.133698
Metadata
- Authors
- Guerquin-Kern, M., Haberlin, M., Pruessmann, K. P., & Unser, M.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- ETH Zurich (CH)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-09
- Volume
- 30
- Issue
- 9
- Pages
- 1649-1660
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2107882641
- Cited by
- 157
- References
- 35
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 6 · 2022: 8 · 2021: 13 · 2020: 5 · 2019: 9 · 2018: 16 · 2017: 13 · 2016: 15 · 2015: 15 · 2014: 18 · 2013: 16 · 2012: 9
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion)
- HAL (submittedVersion, other-oa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- MRI reconstruction, k-space undersampling, ISTA, convex optimization, nonlinear reconstruction, total variation regularization
- MeSH terms
- Algorithms, Brain, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Sensitivity and Specificity, Reproducibility of Results, Nonlinear Dynamics, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.