A Fast Wavelet-Based Reconstruction Method for Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In this work, we exploit the fact that wavelets can represent magnetic resonance images well, with relatively few coefficients. We use this property to improve magnetic resonance imaging (MRI) reconstructions from undersampled data with arbitrary k-space trajectories. Reconstruction is posed as an optimization problem that could be solved with the iterative shrinkage/thresholding algorithm (ISTA) which, unfortunately, converges slowly. To make the approach more practical, we propose a variant that combines recent improvements in convex optimization and that can be tuned to a given specific k-space trajectory. We present a mathematical analysis that explains the performance of the algorithms. Using simulated and in vivo data, we show that our nonlinear method is fast, as it accelerates ISTA by almost two orders of magnitude. We also show that it remains competitive with TV regularization in terms of image quality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952 · cited 1×
“In accordance with Constraint (i), C′ can take the generic quadratically augmented form C′(w,wn) = C(w) + ‖w −wn‖2Λ−MHM , (14) with the constraint that (Λ−MHM) is positive definite, where the weighting matrix Λ plays the role of a tuning parameter.”
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citationAn iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
A New TwIST: Two-Step Iterative Shrinkage/Thresholding Algorithms for Image Restoration
Bioucas-Dias, J. M., & Figueiredo, M. A. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909319 · Cited by 2,064 · cited 1×
“• generic multistep methods that exploit the result of past iterations to speed up convergence, among them: two-step iterative shrinkage/thresholding [14] (TwIST), Nesterov schemes [15], [16], [17], fast ISTA [18] (FISTA), and monotonic FISTA [19] (MFISTA); • methods that optimize wavelet-subband-dependent parameters…”
MethodBeck, A., & Teboulle, M. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028250 · Cited by 2,004 · cited 1×
“• generic multistep methods that exploit the result of past iterations to speed up convergence, among them: two-step iterative shrinkage/thresholding [14] (TwIST), Nesterov schemes [15], [16], [17], fast ISTA [18] (FISTA), and monotonic FISTA [19] (MFISTA); • methods that optimize wavelet-subband-dependent parameters…”
MethodNonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337 · cited 1×
“For these Fourier precomputations, we used the NUFFT algorithm [30] that is made available at http://www.”
MethodAn EM algorithm for wavelet-based image restoration
Figueiredo, M. A. T., & Nowak, R. D. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.814255 · Cited by 1,219 · cited 4×
“The iterative shrinkage/thresholding algorithm (ISTA) [ 2 ], [13], also known as thresholded Landweber (TL), generates a sequence of estimates that converges to the minimizer of (11) when it is unique.”
MethodInfluentialGradient methods for minimizing composite objective functionPreprint
Nesterov, Y. E. (2007) · RePEc: Research Papers in Economics · Cited by 1,096
Research works printed but not linked: 3
- weiss, 2008, Algorithmes rapides d'optimisation convexe application la restauration d'images et la dtection de changements
- wajer, 2001, Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories, Proc ISMRM, 625
- delattre, 2009, Spline-based variational reconstruction of variable density spiral k-space data with automatic parameter adjustment, Proc ISMRM, 2066
Cited by
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
“in magnetic resonance imaging (MRI) [9]–[11] and X-ray”
BackgroundSelf-citationFISTA-Net: Learning a Fast Iterative Shrinkage Thresholding Network for Inverse Problems in Imaging
Xiang, J., Dong, Y., & Yang, Y. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3054167 · Cited by 320
“Sparse representation, lying on the fact that most natural images could be well described by fewer basis coefficients in certain transform domains, is an important tool in imaging [38].”
BackgroundBREAKING THE COHERENCE BARRIER: A NEW THEORY FOR COMPRESSED SENSING
ADCOCK, B., HANSEN, A. C., POON, C., & ROMAN, B. (2017) · Forum of Mathematics, Sigma · doi:10.1017/fms.2016.32 · Cited by 256
“Note that this infinite-dimensional CS model has also been advocated for and implemented in MRI by Guerquin–Kern, H¨aberlin, Pruessmann & Unser [33].”
P‐LORAKS: Low‐rank modeling of local k‐space neighborhoods with parallel imaging data
Haldar, J. P., & Zhuo, J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25717 · Cited by 198
An Introduction to Sparse Stochastic Processes
Unser, M., & Tafti, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107415805 · Cited by 184
Self-citationGeneralized Sampling and Infinite-Dimensional Compressed Sensing
Adcock, B., & Hansen, A. C. (2016) · Foundations of Computational Mathematics · doi:10.1007/s10208-015-9276-6 · Cited by 178
“[38,39] (for earlier work, see Fessler et al.”
MethodLiu, Y., Zhan, Z., Cai, J.-F., Guo, D., Chen, Z., & Qu, X. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2550080 · Cited by 177
MR Image Reconstruction Using Deep Density Priors
Tezcan, K. C., Baumgartner, C. F., Luechinger, R., Pruessmann, K. P., & Konukoglu, E. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2887072 · Cited by 167
“The random undersam-pling approach was primarily motivated by the compressed sensing framework [3], [4], [5], [6], [7], where the incoherence between k-space sampling and some sparsifying transform was exploited.”
MethodSelf-citationYang, F., Dogan, N., Stoyanova, R., & Ford, J. C. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.05.017 · Cited by 112
Zhang, Y., Dong, Z., Phillips, P., Wang, S., Ji, G., & Yang, J. (2015) · Information Sciences · doi:10.1016/j.ins.2015.06.017 · Cited by 110
Epigraphical projection and proximal tools for solving constrained convex optimization problems
Chierchia, G., Pustelnik, N., Pesquet, J.-C., & Pesquet‐Popescu, B. (2014) · Signal Image and Video Processing · doi:10.1007/s11760-014-0664-1 · Cited by 117
Spread Spectrum Magnetic Resonance Imaging
Puy, G., Marques, J. P., Gruetter, R., Thiran, J., Ville, D. V. D., Vandergheynst, P., & Wiaux, Y. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2173698 · Cited by 103
On the Generation of Sampling Schemes for Magnetic Resonance Imaging
Boyer, C., Chauffert, N., Ciuciu, P., Kahn, J., & Weiss, P. O. (2016) · SIAM Journal on Imaging Sciences · doi:10.1137/16m1059205 · Cited by 105
“Lately, techniques based on `1-regularization of wavelet, frame, or learned dictionary coefficients were proven more efficient for large undersampling ratios [37, 24, 6, 50].”
MethodAdcock, B., Hansen, A. C., & Poon, C. (2013) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2013.07.001 · Cited by 76
Adcock, B., Hansen, A. C., & Roman, B. (2015) · Applied and numerical harmonic analysis · doi:10.1007/978-3-319-16042-9_5 · Cited by 76
Rapid compressed sensing reconstruction of 3D non‐Cartesian MRI
Baron, C. A., Dwork, N., Pauly, J. M., & Nishimura, D. G. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26928 · Cited by 85
Zhang, Y., Wang, S., Ji, G., & Dong, Z. (2014) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.22059 · Cited by 75
Continuous Compressed Sensing for Surface Dynamical Processes with Helium Atom Scattering
Jones, A., Tamtögl, A., Calvo‐Almazán, I., & Hansen, A. C. (2016) · Scientific Reports · doi:10.1038/srep27776 · Cited by 71
Ning, B., Qu, X., Guo, D., Hu, C., & Chen, Z. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.07.010 · Cited by 72
“In addition, redundancy in SIDWT further improves the reconstruction quality [18,22,38-40].”
BackgroundMethodOn Stable Reconstructions from Nonuniform Fourier Measurements
Adcock, B., Gatarić, M., & Hansen, A. C. (2014) · SIAM Journal on Imaging Sciences · doi:10.1137/130943431 · Cited by 67
“Furthermore, nonuniform sampling patterns—in particular, spiral trajectories (see [12, 24, 38, 45, 55] and references therein)—have become increasingly popular in MRI applications in the last several decades.”
Bastounis, A., & Hansen, A. C. (2017) · SIAM Journal on Imaging Sciences · doi:10.1137/15m1043972 · Cited by 87
“CS recovery (x̃1) Flip in levels recovery Subsampling pattern College 1 12% samples DFT·DWT−13 MRI, Spectroscopy, Radio- interferometry College 2 97% samples DFT·DWT−14 MRI, Spectroscopy, Radio- interferometry Rocks 12% samples HAD·DWT−12 Comp. imag., Hadamard spectroscopy, Fluorescence microscopy Figure 6.”
BackgroundInfluentialNC-PDNet: A Density-Compensated Unrolled Network for 2D and 3D Non-Cartesian MRI Reconstruction
Ramzi, Z., Radhakrishna, C. G., Starck, J., & Ciuciu, P. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3144619 · Cited by 91
“In the latter framework, a hand-crafted decomposition basis is used to express the sparsity of the image to be reconstructed in a transform domain [5], [6].”
MethodBenning, M., Gladden, L. F., Holland, D. J., Schönlieb, C., & Valkonen, T. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.10.003 · Cited by 69
“[34]).”
A Parallel Proximal Algorithm for Anisotropic Total Variation Minimization
Kamilov, U. S. (2016) · IEEE Transactions on Image Processing · doi:10.1109/tip.2016.2629449 · Cited by 67
Breaking the coherence barrier: A new theory for compressed sensingPreprint
Adcock, B., Hansen, A. C., Poon, C., & Roman, B. (2013) · arXiv (Cornell University) · doi:10.48550/arxiv.1302.0561 · Cited by 62
3D image‐based navigators for coronary MR angiography
Addy, N. O., Ingle, R. R., Luo, J., Baron, C. A., Yang, P. C.-M., Hu, B. S., & Nishimura, D. G. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26269 · Cited by 59
One-Dimensional Deep Low-Rank and Sparse Network for Accelerated MRI
Wang, Z., Qian, C., Guo, D., Sun, H., Li, R., Zhao, B., & Qu, X. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3203312 · Cited by 74
“insightful sparse[2, 7-14], low-rank[5, 15-17] priors or both of them[18-20] have been used to regularize the image or k-space for improved reconstructions.”
Adcock, B., Gatarić, M., & Hansen, A. C. (2015) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2015.09.006 · Cited by 56
“We also remark that our analog recovery model is the same as that used with great success in the recent work of Guerquin-Kern, Haberlin, Pruessmann and Unser [32] on iterative, wavelet-based reconstructions for MRI.”
A Practical Guide to the Recovery of Wavelet Coefficients from Fourier Measurements
Gatarić, M., & Poon, C. (2016) · SIAM Journal on Scientific Computing · doi:10.1137/15m1018630 · Cited by 55
“Weremark that although the efficient recovery of wavelet coefficients from Fourier samples was already considered in [24], that work did not provide a comprehensive explanation of the implementation using boundary-corrected wavelets and various types of Fourier sampling.”
BackgroundTwo-level ℓ1 minimization for compressed sensing
Huang, X., Liu, Y., Shi, L., Huffel, S. V., & Suykens, J. A. K. (2014) · Signal Processing · doi:10.1016/j.sigpro.2014.09.028 · Cited by 64
On the stable sampling rate for binary measurements and wavelet reconstruction
Thesing, L., & Hansen, A. C. (2018) · Apollo (University of Cambridge) · doi:10.17863/cam.30213 · Cited by 50
On the stable sampling rate for binary measurements and wavelet reconstruction
Hansen, A. C., & Thesing, L. (2018) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2018.08.004 · Cited by 51
“The key issue is that the mi cannot be chosen freely, but are dictated by the modality of the sampling device, say an Magnetic Resonance Imaging (MRI) scanner providing Fourier samples or a fluorescence microscope giving binary measurements.”
BackgroundInfluentialZhang, X., Lu, H., Guo, D., Bao, L., Huang, F., Xu, Q., & Qu, X. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101987 · Cited by 50
A Majorize-Minimize Memory Gradient method for complex-valued inverse problems
Florescu, A., Chouzenoux, É., Pesquet, J.-C., Ciuciu, P., & Ciochină, S. (2013) · Signal Processing · doi:10.1016/j.sigpro.2013.09.026 · Cited by 46
Energy Preserved Sampling for Compressed Sensing MRI
Zhang, Y., Peterson, B. S., Ji, G., & Dong, Z. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/546814 · Cited by 61
“FWISTA combines the advantages of generic step method, wavelet-subband-dependent methods, and random shifting technique [24].”
MethodWavelet Shrinkage With Consistent Cycle Spinning Generalizes Total Variation Denoising
Kamilov, U. S., Bostan, E., & Unser, M. A. (2012) · IEEE Signal Processing Letters · doi:10.1109/lsp.2012.2185929 · Cited by 45
“The performance of the method can be further improved, at little computational cost, by using the technique known as cycle spinning [2]–[4].”
BackgroundMethodSelf-citationRapacchi, S., Han, F., Natsuaki, Y., Kroeker, R. M., Plotnik, A. N., Lehrman, E. D., Sayre, J. W., Laub, G. A., Finn, J. P., & Hu, P. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24842 · Cited by 44
Balanced Sparse Model for Tight Frames in Compressed Sensing Magnetic Resonance Imaging
Liu, Y., Cai, J., Zhan, Z., Guo, D., Ye, J., Chen, Z., & Qu, X. (2015) · PLoS ONE · doi:10.1371/journal.pone.0119584 · Cited by 51
“On the contrary, redundant wavelets, such as X-let [18 – 24] and others [25 – 31], can significantly improve the image quality [14 – 17].”
3D Steerable Wavelets in Practice
Chenouard, N., & Unser, M. A. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2206044 · Cited by 43
“In particular, wavelet-based techniques have been developed for MRI reconstruction [1], 3D deconvolution microscopy [2], and medical image coding [3].”
MethodSelf-citationSelf-Supervised Deep Active Accelerated MRIPreprint
Jin, K. H., Unser, M. A., & Yi, K. M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1901.04547 · Cited by 66
“This problem, often referred to as accelerated MRI, is traditionally tackled by exploiting the fact that MRI images, even when sampled fully, are sparse in nature once transformed into, for example, wavelets [1], [4], and by considering the statistics of the target data [5].”
BackgroundSelf-citationHigh‐resolution variable‐density 3D cones coronary MRA
Addy, N. O., Ingle, R. R., Wu, H. H., Hu, B. S., & Nishimura, D. G. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25803 · Cited by 43
Breaking the coherence barrier: asymptotic incoherence and asymptotic sparsity in compressed sensingPreprint
Adcock, B., Hansen, A. C., Poon, C., & Roman, B. (2013) · arXiv (Cornell University) · Cited by 40
Stationary wavelet transform for under-sampled MRI reconstruction
Kayvanrad, M. H., McLeod, A. J., Baxter, J. S. H., McKenzie, C. A., & Peters, T. M. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.08.004 · Cited by 33
Chaâri, L., Ciuciu, P., Mériaux, S., & Pesquet, J.-C. (2014) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-014-0436-5 · Cited by 35
“The minimization of this criterion relies on the Parallel ProXimal Algorithm (PPXA) [47] which can address a broader scope of optimization problems than the forward-backward and Douglas-Rachford methods employed in [37], or even FISTA as used in [48].”
Li, K., Chandrasekera, T. C., Li, Y., & Holland, D. J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2827318 · Cited by 34
“It can be shown that the same statements would hold true for any positive weighting matrix under certain conditions [14], and the weighted l1 norm approach has been widely implemented [14], [18], [20].”
BackgroundPySAP: Python Sparse Data Analysis Package for multidisciplinary image processing
Farrens, S., Grigis, A., Gueddari, L. E., Ramzi, Z., Radhakrishna, C. G., Starck, S., Sarthou, B., Cherkaoui, H., Ciuciu, P., & Starck, J. (2020) · Astronomy and Computing · doi:10.1016/j.ascom.2020.100402 · Cited by 30
Zhang, Y., Yang, J., Yang, J., Liu, A., & Sun, P. (2016) · International Journal of Biomedical Imaging · doi:10.1155/2016/9416435 · Cited by 28
“[39] proposed a variant of ISTA, which is the combination of recent improvements in convex optimization.”
BackgroundA Consistent and Stable Approach to Generalized Sampling
Poon, C. (2014) · Journal of Fourier Analysis and Applications · doi:10.1007/s00041-014-9342-5 · Cited by 28
Adcock, B., Hansen, A. C., Roman, B., & Teschke, G. (2013) · arXiv (Cornell University) · doi:10.48550/arxiv.1310.1141 · Cited by 27
“For an infinite-dimensional implementation of compressed sensing in MRI see (Guerquin-Kern et al. 2011).”
BackgroundSpatiotemporal Flexible Sparse Reconstruction for Rapid Dynamic Contrast-Enhanced MRI
Hu, Y., Zhang, X., Chen, D., Yan, Z., Shen, X., Yan, G., Ou-yang, L., Lin, J., Dong, J., & Qu, X. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3091881 · Cited by 26
Adcock, B., Hansen, A. C., Roman, B., & Teschke, G. (2014) · Advances in imaging and electron physics · doi:10.1016/b978-0-12-800146-2.00004-7 · Cited by 27
Zhang, Y., Dong, Z., Ji, G., & Wang, S. (2014) · Journal of Electromagnetic Waves and Applications · doi:10.1080/09205071.2014.967365 · Cited by 24
“Λ is the weighting matrix that acts as a tuning parameter [ 26].”
BackgroundAutomated Classification of Brain MR Images Using Wavelet-Energy and Support Vector Machines
Zhang, G., Wang, Q., Feng, C.-M., Lee, E., Ji, G., Wang, S., Zhang, Y., & Yan, J. (2015) · International Conference on Mechatronics, Electronic, Industrial and Control Engineering (MEIC) · doi:10.2991/meic-15.2015.155 · Cited by 24
“Scholars tend to use wavelets energy as inputs to a support vector machine to determine whether a MRI of the human brain is normal or abnormal [8-11].”
BackgroundSaucedo, A., Lefkimmiatis, S., Rangwala, N., & Sung, K. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2659742 · Cited by 23
“We use the ISTA formalism [25], [26] to solve (11), since the regularization functional is convex but non-smooth [24].”
MethodYang, X., Luo, Y., Chen, S., Zhen, X., Yu, Q., & Liu, K. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.10.025 · Cited by 22
A Faithful Deep Sensitivity Estimation for Accelerated Magnetic Resonance Imaging
Wang, Z., Fang, H., Qian, C., Shi, B., Bao, L., Zhu, L., Zhou, J., Wei, W., Lin, J., Guo, D., et al. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3360128 · Cited by 23
“The former typically pre-acquires [3] or pre-estimates (e.g., using ESPIRiT [6]) the sensitivity maps from the autocalibration signal (ACS), and further applies sparse regularizations [2], [7], [8], [9], [10], [11] to coil-combined images to reduce the reconstruction error.”
MethodPotential of compressed sensing in quantitative MR imaging of cancer
Smith, D. S., Li, X., Abramson, R. G., Quarles, C. C., Yankeelov, T. E., & Welch, E. B. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0041 · Cited by 21
“[27] Guerquin-Kern M, Haberlin M, Pruessmann KP, Unser M.”
BackgroundGueddari, L. E., Lazarus, C., Carrie, H., Vignaud, A., & Ciuciu, P. (2018) · IEEE Sensor Array and Multichannel Signal Processing Workshop (SAM) · doi:10.1109/sam.2018.8448776 · Cited by 21
“For MR image reconstruction, many nonlinear iterative algorithms have been proposed in the CS framework for the last decade, either promoting sparsity in an appropriate domain (total variation, wavelets, data-driven dictionary) or low-rank reconstruction as regularizing constraints [14–17].”
MethodAthavale, P., Xu, R., Radau, P. E., Nachman, A., & Wright, G. A. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.04.013 · Cited by 19
Provable Preconditioned Plug-and-Play Approach for Compressed Sensing MRI Reconstruction
Hong, T., Xu, X., Hu, J., & Fessler, J. A. (2024) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2024.3477329 · Cited by 22
“Classical choices for ϕ ( · ) that have shown to be useful for MRI reconstruction include total variation (TV) [4, 6, 7], wavelets [8, 9], dictionary learning [10, 11], and low-rank [12], to name a few.”
BackgroundNon-Cartesian MRI Reconstruction With Automatic Regularization Via Monte-Carlo SURE
Ramani, S., Weller, D. S., Nielsen, J., & Fessler, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2257829 · Cited by 20
On the absence of the RIP in real-world applications of compressed sensing and the RIP in levelsPreprint
Bastounis, A., & Hansen, A. C. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1411.4449 · Cited by 18
“simplified example does. Note also that changing from the finite-dimensional model (which is far from optimal for infinitedimensional problems such as MRI) to the infinite-dimensional model described in [3,4,9,32,33,41] will not fix the problem. 2.3 The weighted RIP Consideration of a different explanation for the success…”
InfluentialSignal and Image Reconstruction with Tight Frames via Unconstrained ℓ1−αℓ2 -Analysis Minimizations
Li, P., Ge, H., & Geng, P. (2022) · Signal Processing · doi:10.1016/j.sigpro.2022.108755 · Cited by 17
Hu, K., Cheng, Q., Li, B., & Gao, X. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.08.014 · Cited by 16
Non-uniform Recovery Guarantees for Binary Measurements and Infinite-Dimensional Compressed Sensing
Thesing, L., & Hansen, A. C. (2019) · Apollo (University of Cambridge) · doi:10.17863/cam.65588 · Cited by 15
Lu, B., Fu, L., Pan, Y., & Dong, Y. (2024) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2024.102345 · Cited by 15
Variational Justification of Cycle Spinning for Wavelet-Based Solutions of Inverse Problems
Kamilov, U. S., Bostan, E., & Unser, M. A. (2014) · IEEE Signal Processing Letters · doi:10.1109/lsp.2014.2334306 · Cited by 13
Self-citationCherkaoui, H., Gueddari, L. E., Lazarus, C., Grigis, A., Poupon, F., Vignaud, A., Farrens, S., Starck, J., & Ciuciu, P. (2018) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco.2018.8553476 · Cited by 12
Ramani, S., & Fessler, J. A. (2012) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2012.6235728 · Cited by 11
“While OWT is appealing from the standpoint of memory, its shiftvariant nature can lead to block-artifacts in the reconstruction [5, 6].”
BackgroundMethodA Complex Quasi-Newton Proximal Method for Image Reconstruction in Compressed Sensing MRI
Hong, T., Hernández-García, L., & Fessler, J. A. (2024) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2024.3369404 · Cited by 22
“In general, MR images are not sparse but they can be sparsely represented under some transforms, e.g., total variation (TV) [1], wavelets [2], and transform-learning [3] etc. Recently, more advanced priors or frameworks were introduced for CS MRI reconstruction, such as low-rank [4], plug and play…”
BackgroundDeep Neural Network Structured Sparse Coding for Online Processing
Zhao, H., Ding, S., Xiang, L., & Huang, H. (2018) · IEEE Access · doi:10.1109/access.2018.2882531 · Cited by 11
“Subband Adaptive Iterative Shrinkage Thresholding Algorithm (SISTA) [12], [13], a modified version of ISTA, can accelerate the convergence via processing of ISTA in subbands.”
MethodWavelet-domain TI Wiener-like filtering for complex MR data denoising
Hu, K., Cheng, Q., & Gao, X. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.05.011 · Cited by 11
“While most of them consider the incorporated noise as additive Gaussian noise, they do not realize the Rician distribution of magnitude MR images [9–16].”
BackgroundYang, G., Lv, J., Chen, Y., Huang, J., & Zhu, J. (2022) · Intelligent systems reference library · doi:10.1007/978-3-030-91390-8_13 · Cited by 23
MRI reconstruction based on Bayesian group sparse representation
Cao, J., Liu, S., Liu, H., & Zhang, K. (2021) · Signal Processing · doi:10.1016/j.sigpro.2021.108151 · Cited by 10
Wu, G., & Luo, S. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.12.009 · Cited by 10
“In CS-based MR image reconstruction, almost all exist ing algorithms for solving (1) employ iterative schemes [4,5,8,9,13,14], which make slow processes to find the final solution.”
MethodChierchia, G., Pustelnik, N., Pesquet, J.-C., & Pesquet‐Popescu, B. (2012) · arXiv (Cornell University) · doi:10.48550/arxiv.1210.5844 · Cited by 20
“The efficiency of these methods in the solution of inverse problems has been widely studied in the recent signal and image processing literature (see for instance [4,5,6,7,8,9] and references therein).”
Qu, B., Zhang, Z., Chen, Y., Qian, C., Kang, T., Lin, J., Chen, L., Wu, Z., Wang, J., Zheng, G., et al. (2023) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2023.107425 · Cited by 9
MRI reconstruction using a joint constraint in patch-based total variational framework
Liu, S., Cao, J., Liu, H., Shen, X., Zhang, K., & Wang, P. (2017) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2017.03.017 · Cited by 9
True constructive interference in the steady state (trueCISS)
Hilbert, T., Nguyen, D., Thiran, J., Krüger, G., Kober, T., & Bieri, O. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26836 · Cited by 9
Multi-wavelet level comparison on compressive sensing for MRI image reconstruction
Irawati, I. D., Hadiyoso, S., & Hariyani, Y. S. (2020) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/eei.v9i4.2347 · Cited by 9
“[17] combined sampling method with arbitrary k-space trajectories using wavelet and iterative shrinkage/thresholding algorithm (ISTA) to accelerate MRI reconstruction.”
BackgroundMethodDeep frequency-recurrent priors for inverse imaging reconstruction
He, Z., Hong, K., Zhou, J., Liang, D., Wang, Y., & Liu, Q. (2021) · Signal Processing · doi:10.1016/j.sigpro.2021.108320 · Cited by 14
On Asymptotic Incoherence and Its Implications for Compressed Sensing of Inverse Problems
Jones, A. D., Adcock, B., & Hansen, A. C. (2015) · IEEE Transactions on Information Theory · doi:10.1109/tit.2015.2508562 · Cited by 9
Generalized total variation denoising via augmented Lagrangian cycle spinning with Haar wavelets
Kamilov, U. S., Bostan, E., & Unser, M. A. (2012) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2012.6288032 · Cited by 10
“Wavelet regularization with cycle spinning is often used in denoising and inverse problems and consistently improves performance at no extra cost [6] [7].”
Self-citationFast compressive beamforming with a modified fast iterative shrinkage-thresholding algorithm
Wang, S., Chi, C., Jin, S., Wang, P., Liu, J., & Huang, H. (2021) · The Journal of the Acoustical Society of America · doi:10.1121/10.0004997 · Cited by 8
Qiao, X., Huang, Y., & Li, W. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29575 · Cited by 9
“In CS-MRI, regularizers such as L 1 penalty on images, 36 discrete wavelet transform, 37 wavelet, 38 and total variation 39,40 etc . are commonly used.”
MethodLinear Reconstructions and the Analysis of the Stable Sampling Rate
Thesing, L., & Hansen, A. C. (2018) · Sampling Theory in Signal and Image Processing · doi:10.1007/bf03549616 · Cited by 8
Group-Sparsity-Based Super-Resolution Dipole Orientation Mapping
Chen, L., Wang, M., Zhang, X., Zhang, M., Hu, Y., Shi, Z., Xi, P., & Gao, J. T. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2910221 · Cited by 7
“We apply fast iterative shrinkage thresholding algorithm (FISTA) to solve g(r, t) of GS-SDOM [30]–[32].”
MethodMultidimensional Wavelet-based Regularized Reconstruction for Parallel Acquisition in NeuroimagingPreprint
Chaâri, L., Mériaux, S., Badillo, S., Pesquet, J.-C., & Ciuciu, P. (2012) · arXiv (Cornell University) · Cited by 8
Jiang, B., Yue, T., & Hu, X. (2023) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn54540.2023.10191156 · Cited by 7
“Some researchers regarded the thermal noise in MR images as Gaussian noise [32-40]; however, it has been emphasized that thermal noise in MR images obeys Rician distribution whose properties are greatly different from Gaussian noise.”
BackgroundCS-MRI reconstruction via group-based eigenvalue decomposition and estimation
Liu, S., Cao, J., Wu, G., Liu, H., Tan, X., & Zhou, X. (2017) · Neurocomputing · doi:10.1016/j.neucom.2017.12.038 · Cited by 7
Recent advances in highly accelerated 3D MRI
Zhou, Y., Wang, H., Liu, C., Liao, B., Li, Y., Zhu, Y., Hu, Z., Liao, J., & Liang, D. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/acc0cd · Cited by 10
Improved regularisation constraints for compressed sensing of multi-slice MRI
Islam, R., Lambert, A. J., Pickering, M. R., Scarvell, J. M., & Smith, P. N. (2014) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2014.925304 · Cited by 7
“…¼ Wj xðnÞ þ tF*u y2 FuxðnÞ ; ð7Þ where zðnÞj are the Landweber coefficients of iteration n, Wj is the forward wavelet transform operation for subband j and t is the step size which can be selected based on the eigenvalues of F*uFu, as in Fessler et al. (2005) and Guerquin-Kern et al. (2011).”
MethodInfluentialSparsity Promoting Adaptive Regularization for Compressed Sensing Parallel MRI
Mathew, R. S., & Paul, J. S. (2017) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2017.2787911 · Cited by 7
“Methods to accelerate ISTA either use information from past iterations such as the two-step iterative thresholding (TwIST) [14] and fast ISTA (FISTA) [15], optimize the wavelet parameters such as multi-level TL (MLTL) [16], [17] and Subband Adaptive ISTA (SISTA) [18] or use a combination of the two types as in Fast We…”
MethodBorisch, E. A., Froemming, A. T., Grimm, R. C., Kawashima, A., Trzasko, J. D., & Riederer, S. J. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29447 · Cited by 6
Online MR image reconstruction for compressed sensing acquisition in T2* imaging
Gueddari, L. E., Chouzenoux, É., Vignaud, A., Pesquet, J.-C., & Ciuciu, P. (2019) · Wavelets and Sparsity · doi:10.1117/12.2527881 · Cited by 6
Subband-dependent compressed sensing in local CT reconstruction
Hashemi, S., Beheshti, S., Cobbold, R. S. C., & Paul, N. S. (2015) · Signal Image and Video Processing · doi:10.1007/s11760-015-0852-7 · Cited by 6
“…been proposed to accelerate the convergence: (1) combining the result of past iterations to speed up convergence, such as two-step iterative shrinkage/thresholding (TwIST) [12] and fast ISTA (FISTA) [16]; (2) use of wavelet subband-dependent CS methods like subband adaptive ISTA (SISTA) [13,14].”
MethodHybrid regularization for MRI reconstruction with static field inhomogeneity correction
Compton, R., Osher, S., & Bouchard, L. (2013) · Inverse Problems and Imaging · doi:10.3934/ipi.2013.7.1215 · Cited by 5
Chierchia, G., Pustelnik, N., & Pesquet‐Popescu, B. (2014) · Cited by 5
On stable reconstructions from univariate nonuniform Fourier measurements
Adcock, B., Gatarić, M., & Hansen, A. C. (2013) · Cited by 5
Lazarus, C., Weiss, P. O., Vignaud, A., & Ciuciu, P. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2018.07.006 · Cited by 5
“tion [1, 19, 20, 21, 22] sides, the question on the actual limitations to the acceleration rate in CS for a given experimental setup has been hardly addressed.”
Background
Metadata
- Authors
- Guerquin-Kern, M., Haberlin, M., Pruessmann, K. P., & Unser, M.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- ETH Zurich (CH)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-09
- Volume
- 30
- Issue
- 9
- Pages
- 1649-1660
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2107882641
- Cited by
- 157
- References
- 35
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 6 · 2022: 8 · 2021: 13 · 2020: 5 · 2019: 9 · 2018: 16 · 2017: 13 · 2016: 15 · 2015: 15 · 2014: 18 · 2013: 16 · 2012: 9
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion)
- HAL (submittedVersion, other-oa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- MRI reconstruction, k-space undersampling, ISTA, convex optimization, nonlinear reconstruction, total variation regularization
- MeSH terms
- Algorithms, Brain, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Sensitivity and Specificity, Reproducibility of Results, Nonlinear Dynamics, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.