A Fast Wavelet-Based Reconstruction Method for Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In this work, we exploit the fact that wavelets can represent magnetic resonance images well, with relatively few coefficients. We use this property to improve magnetic resonance imaging (MRI) reconstructions from undersampled data with arbitrary k-space trajectories. Reconstruction is posed as an optimization problem that could be solved with the iterative shrinkage/thresholding algorithm (ISTA) which, unfortunately, converges slowly. To make the approach more practical, we propose a variant that combines recent improvements in convex optimization and that can be tuned to a given specific k-space trajectory. We present a mathematical analysis that explains the performance of the algorithms. Using simulated and in vivo data, we show that our nonlinear method is fast, as it accelerates ISTA by almost two orders of magnitude. We also show that it remains competitive with TV regularization in terms of image quality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952 · cited 1×
“In accordance with Constraint (i), C′ can take the generic quadratically augmented form C′(w,wn) = C(w) + ‖w −wn‖2Λ−MHM , (14) with the constraint that (Λ−MHM) is positive definite, where the weighting matrix Λ plays the role of a tuning parameter.”
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citationAn iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
A New TwIST: Two-Step Iterative Shrinkage/Thresholding Algorithms for Image Restoration
Bioucas-Dias, J. M., & Figueiredo, M. A. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909319 · Cited by 2,064 · cited 1×
“• generic multistep methods that exploit the result of past iterations to speed up convergence, among them: two-step iterative shrinkage/thresholding [14] (TwIST), Nesterov schemes [15], [16], [17], fast ISTA [18] (FISTA), and monotonic FISTA [19] (MFISTA); • methods that optimize wavelet-subband-dependent parameters…”
MethodBeck, A., & Teboulle, M. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028250 · Cited by 2,004 · cited 1×
“• generic multistep methods that exploit the result of past iterations to speed up convergence, among them: two-step iterative shrinkage/thresholding [14] (TwIST), Nesterov schemes [15], [16], [17], fast ISTA [18] (FISTA), and monotonic FISTA [19] (MFISTA); • methods that optimize wavelet-subband-dependent parameters…”
MethodNonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337 · cited 1×
“For these Fourier precomputations, we used the NUFFT algorithm [30] that is made available at http://www.”
MethodAn EM algorithm for wavelet-based image restoration
Figueiredo, M. A. T., & Nowak, R. D. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.814255 · Cited by 1,219 · cited 4×
“The iterative shrinkage/thresholding algorithm (ISTA) [ 2 ], [13], also known as thresholded Landweber (TL), generates a sequence of estimates that converges to the minimizer of (11) when it is unique.”
MethodInfluentialGradient methods for minimizing composite objective functionPreprint
Nesterov, Y. E. (2007) · RePEc: Research Papers in Economics · Cited by 1,096
Nonlinear image recovery with half-quadratic regularization
Geman, D., & Yang, C. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.392335 · Cited by 1,000 · cited 1×
“For TV regularizations, we considered the iteratively reweighted least-squares algorithm (IRLS), which corresponds to the additive form of half-quadratic minimization [31], [32].”
MethodNESTA: A Fast and Accurate First-Order Method for Sparse Recovery
Becker, S., Bobin, J., & Candès, E. J. (2009) · Cited by 897
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
Chambolle, A., De Vore, R. A., Lee, N.-Y., & Lucier, B. J. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661182 · Cited by 751
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<849::aid-mrm4>3.0.co;2-z · Cited by 576
Self-citationCompressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397
Simple analytic spiral K-space algorithm
Glover, G. H. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199908)42:2<412::aid-mrm25>3.0.co;2-u · Cited by 242 · cited 1×
“Spiral acquisition schemes are attractive because of their versatility and the fact that they can be implemented with smooth gradient switching [34], [35].”
BackgroundA Fast Thresholded Landweber Algorithm for Wavelet-Regularized Multidimensional Deconvolution
Vonesch, C., & Unser, M. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.917103 · Cited by 203
Self-citationA l 1-Unified Variational Framework for Image Restoration
Bect, J., Blanc‐Féraud, L., Aubert, G., & Chambolle, A. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-24673-2_1 · Cited by 199 · cited 1×
“Instead, the iterative shrinkage/thresholding algorithm [2], [ 12 ], [13] (ISTA) is an elegant and nonparametric method that is mathematically proven to converge.”
MethodUnser, M., & Blu, T. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807000 · Cited by 169
Self-citation3D z-shim method for reduction of susceptibility effects in BOLD fMRI
Glover, G. H. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199908)42:2<290::aid-mrm11>3.0.co;2-n · Cited by 160
Fessler, J. A., Lee, S., Olafsson, V. T., Shi, H. R., & Noll, D. C. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853152 · Cited by 153 · cited 1×
“Matrixto-vector multiplication with A = MM , specifically, EE, have an efficient implementation thanks to the convolution structure of the problem [28], [29].”
MethodRegularization in Image Restoration and Reconstruction
Karl, W. C. (2005) · Elsevier eBooks · doi:10.1016/b978-012119792-6/50075-9 · Cited by 127 · cited 1×
“For practical situations where the ground-truth reference is not available, it is possible to adjust by considering well-established techniques such as the discrepancy principle, generalized cross validation, or L-curve method [ 33 ].”
MethodSimple analytic variable density spiral design
Kim, D., Elfar Adalsteinsson, A., & Spielman, D. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10493 · Cited by 117 · cited 1×
“Spiral acquisition schemes are attractive because of their versatility and the fact that they can be implemented with smooth gradient switching [34], [35].”
BackgroundRegularized sensitivity encoding (SENSE) reconstruction using bregman iterations
Лю, Б., King, K., Steckner, M., Xie, J., Sheng, J., & Ying, L. L. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21799 · Cited by 103
A transmit/receive system for magnetic field monitoring of in vivo MRI
Barmet, C., Zanche, N. D., Wilm, B. J., & Pruessmann, K. P. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21996 · Cited by 101 · cited 1×
“A field camera with 12 probes was used to monitor the actual k-space trajectory [36].”
MethodSelf-citationA Fast Multilevel Algorithm for Wavelet-Regularized Image Restoration
Vonesch, C., & Unser, M. A. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2008073 · Cited by 91 · cited 2×
“ Methods that optimize wavelet-subband-dependent parameters with respect to the reconstruction problem: multilevel thresholded Landweber (MLTL) [20], [ 21 ] and subband adaptive ISTA (SISTA) [22].”
MethodSelf-citationFaster Imaging with Randomly Perturbed, Undersampled Spirals and |L|_1 Reconstruction
Lustig, M. S., Lee, J. H., Donoho, D. L., & Pauly, J. M. (2004) · Cited by 56
A Connection Between Half-Quadratic Criteria and EM Algorithms
Champagnat, F., & Idier, J. (2004) · IEEE Signal Processing Letters · doi:10.1109/lsp.2004.833511 · Cited by 50 · cited 1×
“For TV regularizations, we considered the iteratively reweighted least-squares algorithm (IRLS), which corresponds to the additive form of half-quadratic minimization [31], [32].”
MethodA statistical approach to SENSE regularization with arbitrary k ‐space trajectories
Ying, L. L., Liu, B., Steckner, M., Wu, G., Wu, M., & Li, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21665 · Cited by 49
A Subband Adaptive Iterative Shrinkage/Thresholding Algorithm
Bayram, İ., & Selesnick, I. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2036064 · Cited by 37
Wavelet-regularized reconstruction for rapid MRI
Guerquin-Kern, M., Ville, D. V. D., Vonesch, C., Baritaux, J.-C., Pruessmann, K. P., & Unser, M. A. (2009) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2009.5193016 · Cited by 35
Self-citationAutocalibrated regularized parallel mri reconstruction in the wavelet domain
Chaâri, L., Pesquet, J.-C., Benazza‐Benyahia, A., & Ciuciu, P. (2008) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2008.4541106 · Cited by 17
Improved spiral sense reconstruction using a multiscale wavelet model
Liu, B., Abdelsalam, E., Sheng, J., & Ying, L. L. (2008) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2008.4541294 · Cited by 12
Analytical form of Shepp-Logan phantom for parallel MRI
Guerquin-Kern, M., Karahanoğlu, F. I., Ville, D. V. D., Pruessmann, K. P., & Unser, M. A. (2010) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2010.5490365 · Cited by 7 · cited 1×
“The corresponding reduction factor, defined as the ratio of the distance of neighboring interleaves with the Nyquist distance, is . 2) Analytical Simulation: We used analytical simulations of the SL brain phantom with a similar coil sensitivity, following the method described in [ 37 ].”
MethodSelf-citation
Research works printed but not linked: 3
- weiss, 2008, Algorithmes rapides d'optimisation convexe application la restauration d'images et la dtection de changements
- wajer, 2001, Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories, Proc ISMRM, 625
- delattre, 2009, Spline-based variational reconstruction of variable density spiral k-space data with automatic parameter adjustment, Proc ISMRM, 2066
Cited by
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
“in magnetic resonance imaging (MRI) [9]–[11] and X-ray”
BackgroundSelf-citationFISTA-Net: Learning a Fast Iterative Shrinkage Thresholding Network for Inverse Problems in Imaging
Xiang, J., Dong, Y., & Yang, Y. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3054167 · Cited by 320
“Sparse representation, lying on the fact that most natural images could be well described by fewer basis coefficients in certain transform domains, is an important tool in imaging [38].”
BackgroundBREAKING THE COHERENCE BARRIER: A NEW THEORY FOR COMPRESSED SENSING
ADCOCK, B., HANSEN, A. C., POON, C., & ROMAN, B. (2017) · Forum of Mathematics, Sigma · doi:10.1017/fms.2016.32 · Cited by 256
“Note that this infinite-dimensional CS model has also been advocated for and implemented in MRI by Guerquin–Kern, H¨aberlin, Pruessmann & Unser [33].”
P‐LORAKS: Low‐rank modeling of local k‐space neighborhoods with parallel imaging data
Haldar, J. P., & Zhuo, J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25717 · Cited by 198
An Introduction to Sparse Stochastic Processes
Unser, M., & Tafti, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107415805 · Cited by 184
Self-citation
Metadata
- Authors
- Guerquin-Kern, M., Haberlin, M., Pruessmann, K. P., & Unser, M.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- ETH Zurich (CH)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-09
- Volume
- 30
- Issue
- 9
- Pages
- 1649-1660
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2107882641
- Cited by
- 157
- References
- 35
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 6 · 2022: 8 · 2021: 13 · 2020: 5 · 2019: 9 · 2018: 16 · 2017: 13 · 2016: 15 · 2015: 15 · 2014: 18 · 2013: 16 · 2012: 9
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion)
- HAL (submittedVersion, other-oa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- MRI reconstruction, k-space undersampling, ISTA, convex optimization, nonlinear reconstruction, total variation regularization
- MeSH terms
- Algorithms, Brain, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Sensitivity and Specificity, Reproducibility of Results, Nonlinear Dynamics, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.