CoChat

Automated Measurement of the Arteriolar-to-Venular Width Ratio in Digital Color Fundus Photographs

Open access
Niemeijer, M., Xiayu Xu, Dumitrescu, A. V., Gupta, P., van Ginneken, B., Folk, J. C., Abramoff, M. D. · 2011 · IEEE Transactions on Medical Imaging
Cited by 188

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A decreased ratio of the width of retinal arteries to veins [arteriolar-to-venular diameter ratio (AVR)], is well established as predictive of cerebral atrophy, stroke and other cardiovascular events in adults. Tortuous and dilated arteries and veins, as well as decreased AVR are also markers for plus disease in retinopathy of prematurity. This work presents an automated method to estimate the AVR in retinal color images by detecting the location of the optic disc, determining an appropriate region of interest (ROI), classifying vessels as arteries or veins, estimating vessel widths, and calculating the AVR. After vessel segmentation and vessel width determination, the optic disc is located and the system eliminates all vessels outside the AVR measurement ROI. A skeletonization operation is applied to the remaining vessels after which vessel crossings and bifurcation points are removed, leaving a set of vessel segments consisting of only vessel centerline pixels. Features are extracted from each centerline pixel in order to assign these a soft label indicating the likelihood that the pixel is part of a vein. As all centerline pixels in a connected vessel segment should be the same type, the median soft label is assigned to each centerline pixel in the segment. Next, artery vein pairs are matched using an iterative algorithm, and the widths of the vessels are used to calculate the AVR. We trained and tested the algorithm on a set of 65 high resolution digital color fundus photographs using a reference standard that indicates for each major vessel in the image whether it is an artery or vein. We compared the AVR values produced by our system with those determined by a semi-automated reference system. We obtained a mean unsigned error of 0.06 (SD 0.04) in 40 images with a mean AVR of 0.67. A second observer using the semi-automated system obtained the same mean unsigned error of 0.06 (SD 0.05) on the set of images with a mean AVR of 0.66. The testing data and reference standard used in this study has been made publicly available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2011.2159619

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 188

Metadata

Authors
Niemeijer, M., Xu, X., Dumitrescu, A. V., Gupta, P., van Ginneken, B., Folk, J. C., & Abramoff, M. D.
Venue
IEEE Transactions on Medical Imaging
Published
2011-11
Volume
30
Issue
11
Pages
1941-1950
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2137055403
Cited by
188
References
3
FWCI
7.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Measurement of the Arteriolar-to-Venular Width Ratio in Digital Color Fundus Photographs. https://app.cochat.ai/papers/10.1109/tmi.2011.2159619
The paper
Niemeijer, M., Xu, X., Dumitrescu, A. V., Gupta, P., van Ginneken, B., Folk, J. C., & Abramoff, M. D. (2011). Automated Measurement of the Arteriolar-to-Venular Width Ratio in Digital Color Fundus Photographs. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2011.2159619

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.