A System for Video-Based Navigation for Endoscopic Endonasal Skull Base Surgery
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Surgeries of the skull base require accuracy to safely navigate the critical anatomy. This is particularly the case for endoscopic endonasal skull base surgery (ESBS) where the surgeons work within millimeters of neurovascular structures at the skull base. Today's navigation systems provide approximately 2 mm accuracy. Accuracy is limited by the indirect relationship of the navigation system, the image and the patient. We propose a method to directly track the position of the endoscope using video data acquired from the endoscope camera. Our method first tracks image feature points in the video and reconstructs the image feature points to produce 3D points, and then registers the reconstructed point cloud to a surface segmented from preoperative computed tomography (CT) data. After the initial registration, the system tracks image features and maintains the 2D-3D correspondence of image features and 3D locations. These data are then used to update the current camera pose. We present a method for validation of our system, which achieves submillimeter (0.70 mm mean) target registration error (TRE) results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
Cited by
Ozyoruk, K. B., Gokceler, G. I., Bobrow, T. L., Coskun, G., Incetan, K., Almalioglu, Y., Mahmood, F., Curto, E., Perdigoto, L., Oliveira, M., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102058 · Cited by 270
Visual SLAM for Handheld Monocular Endoscope
Grasa, O. G., Bernal, E., Casado, S., Gil, I., & Montiel, J. M. M. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2282997 · Cited by 155
A Review of Recent Advances in Registration Techniques Applied to Minimally Invasive Therapy
Liao, R., Zhang, L., Sun, Y., Miao, S., & Chefd'Hotel, C. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244869 · Cited by 71
Image-based navigation for functional endoscopic sinus surgery using structure from motion
Leonard, S., Reiter, A., Sinha, A., Ishii, M., Taylor, R. H., & Hager, G. D. (2016) · SPIE Proceedings · doi:10.1117/12.2217279 · Cited by 35
Self-citation
Metadata
- Authors
- Mirota, D. J., Wang, H., Taylor, R. H., Ishii, M., Gallia, G. L., & Hager, G. D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2012-04
- Volume
- 31
- Issue
- 4
- Pages
- 963-976
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2149680049
- Cited by
- 64
- References
- 1
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A System for Video-Based Navigation for Endoscopic Endonasal Skull Base Surgery. https://app.cochat.ai/papers/10.1109/tmi.2011.2176500
- The paper
- Mirota, D. J., Wang, H., Taylor, R. H., Ishii, M., Gallia, G. L., & Hager, G. D. (2012). A System for Video-Based Navigation for Endoscopic Endonasal Skull Base Surgery. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2011.2176500
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.