The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Retinal Microaneurysm Detection Through Local Rotating Cross-Section Profile Analysis
Open accessAbstract
A method for the automatic detection of microaneurysms (MAs) in color retinal images is proposed in this paper. The recognition of MAs is an essential step in the diagnosis and grading of diabetic retinopathy. The proposed method realizes MA detection through the analysis of directional cross-section profiles centered on the local maximum pixels of the preprocessed image. Peak detection is applied on each profile, and a set of attributes regarding the size, height, and shape of the peak are calculated subsequently. The statistical measures of these attribute values as the orientation of the cross-section changes constitute the feature set that is used in a naïve Bayes classification to exclude spurious candidates. We give a formula for the final score of the remaining candidates, which can be thresholded further for a binary output. The proposed method has been tested in the Retinopathy Online Challenge, where it proved to be competitive with the state-of-the-art approaches. We also present the experimental results for a private image set using the same classifier setup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
Computer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening
Seoud, L., Hurtut, T., Chelbi, J., Cheriet, F., & Langlois, J. M. P. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2509785 · Cited by 277
Metadata
- Authors
- Lazar, I., & Hajdu, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-02
- Volume
- 32
- Issue
- 2
- Pages
- 400-407
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2089969656
- Cited by
- 200
- References
- 1
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal Microaneurysm Detection Through Local Rotating Cross-Section Profile Analysis. https://app.cochat.ai/papers/10.1109/tmi.2012.2228665
- The paper
- Lazar, I., & Hajdu, A. (2013). Retinal Microaneurysm Detection Through Local Rotating Cross-Section Profile Analysis. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2012.2228665
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.