Automatic Detection and Measurement of Structures in Fetal Head Ultrasound Volumes Using Sequential Estimation and Integrated Detection Network (IDN)
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Routine ultrasound exam in the second and third trimesters of pregnancy involves manually measuring fetal head and brain structures in 2-D scans. The procedure requires a sonographer to find the standardized visualization planes with a probe and manually place measurement calipers on the structures of interest. The process is tedious, time consuming, and introduces user variability into the measurements. This paper proposes an automatic fetal head and brain (AFHB) system for automatically measuring anatomical structures from 3-D ultrasound volumes. The system searches the 3-D volume in a hierarchy of resolutions and by focusing on regions that are likely to be the measured anatomy. The output is a standardized visualization of the plane with correct orientation and centering as well as the biometric measurement of the anatomy. The system is based on a novel framework for detecting multiple structures in 3-D volumes. Since a joint model is difficult to obtain in most practical situations, the structures are detected in a sequence, one-by-one. The detection relies on Sequential Estimation techniques, frequently applied to visual tracking. The interdependence of structure poses and strong prior information embedded in our domain yields faster and more accurate results than detecting the objects individually. The posterior distribution of the structure pose is approximated at each step by sequential Monte Carlo. The samples are propagated within the sequence across multiple structures and hierarchical levels. The probabilistic model helps solve many challenges present in the ultrasound images of the fetus such as speckle noise, signal drop-out, shadows caused by bones, and appearance variations caused by the differences in the fetus gestational age. This is possible by discriminative learning on an extensive database of scans comprising more than two thousand volumes and more than thirteen thousand annotations. The average difference between ground truth and automatic measurements is below 2 mm with a running time of 6.9 s (GPU) or 14.7 s (CPU). The accuracy of the AFHB system is within inter-user variability and the running time is fast, which meets the requirements for clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Histograms of Oriented Gradients for Human Detection
Dalal, N., & Triggs, B. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.177 · Cited by 33,584
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Tu, Z. (2005) · Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1 · doi:10.1109/iccv.2005.194 · Cited by 397
Carneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.928917 · Cited by 205
Self-citation
Cited by
Automated measurement of fetal head circumference using 2D ultrasound images
van den Heuvel, T. L. A., de Bruijn, D., de Korte, C. L., & Ginneken, B. V. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200412 · Cited by 280
Ultrasound Standard Plane Detection Using a Composite Neural Network Framework
Chen, H., Wu, L., Dou, Q., Qin, J., Li, S., Cheng, J.-Z., Ni, D., & Heng, P.-A. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2685080 · Cited by 164
van den Heuvel, T. L. A., Petros, H., Santini, S., de Korte, C. L., & van Ginneken, B. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.09.015 · Cited by 91
Artificial intelligence in obstetric ultrasound: A scoping review.
Horgan, R., Nehme, L., & Abuhamad, A. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6411 · Cited by 72
“88–91 Two studies focused on deep learning systems for the detection of fetal intra-cranial planes from 2D ultrasound.”
BackgroundYaqub, M., Kelly, B., Papageorghiou, A. T., & Noble, J. A. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.07.013 · Cited by 67
Metadata
- Authors
- Sofka, M., Zhang, J., Good, S., Zhou, S. K., & Comaniciu, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-05
- Volume
- 33
- Issue
- 5
- Pages
- 1054-1070
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2100690439
- Cited by
- 39
- References
- 4
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Detection and Measurement of Structures in Fetal Head Ultrasound Volumes Using Sequential Estimation and Integrated Detection Network (IDN). https://app.cochat.ai/papers/10.1109/tmi.2014.2301936
- The paper
- Sofka, M., Zhang, J., Good, S., Zhou, S. K., & Comaniciu, D. (2014). Automatic Detection and Measurement of Structures in Fetal Head Ultrasound Volumes Using Sequential Estimation and Integrated Detection Network (IDN). IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2014.2301936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.